6.1 INSTALLATION SAFETY
Trina Solar recommends that PV module installation should only be conducted by specialized
persons with experience in PV system installation. All installation work must be in full compliance
with the local regulations and the relevant international electrical standards.
The fire rating of Trina Solar modules complies with relevant standards or local laws and regulations.
Before installation, please carefully check the modules for abnormalities such as glass bursts, cell
cracks, backsheet scratches, deformation of installation holes, broken junction boxes or missing
covers, nameplates falling off or missing, and broken cables or connectors, etc. If any of such
situation is found, please contact Trina Solar customer service in time.
Before installation, please keep modules' electrical components clean and dry. Connectors can
corrode if they are in connected under wet conditions or with water inside the conductive parts. Any
corroded components shall not be used.
The cable length of junction box shall be selected according to the installation mode. When wiring,
the ties for fixing the cables coils shall be removed. The cable shall be fixed on the installation system
(frame or bracket, guide rail) with UV resistant cable ties, in cable conduits or wire cards to avoid
direct sunlight or immersion in water and mechanical damage of the cable; otherwise, it may cause
accelerated aging of the cable or even leakage and fire. Bifacial PV modules should also avoid
blocking the solar cells on the back of the module. The open area should minimize arc coil, which
can reduce the risk of induced lightning impact on PV module.
Do not install modules under rain, snow or windy conditions.
If installing or operate modules after rain or in the morning dew, appropriate
protective measures need to be taken to prevent water vapor from penetrating
into the connector.
Do not allow unauthorized persons to access the installation area.
When installing with scaffolding, make sure that the scaffolding is in a stable position or with anti-
dumping measures, and that the installer should wear a safety belt in accordance with local building
codes.
It is recommended not to stand on the bottom side of the inclined surface of the module during
installation, to prevent the module from slipping and causing casualty.
Please keep the PV module packed in the carton until installation and install them immediately after
unpacking.
Do not wear metallic jewelry which can cause electric shock during installation.
During installation and wiring of PV modules, please use opaque material to cover the PV module
surface completely.
Installation work must be carried out by at least two persons.
Do not stand on the module glass while working. There is a risk of injury or electric shock if the glass
is broken.
Do not loosen or unscrew the screws/clamps/rails of and around the PV module, which may lead to
a reduction of the module's load rating and even fall off.
Do not drop any tools or other objects on the module front- or backside which could cause damage
(visible or non-visible) to the module.
Do not install or use damaged modules. If the surface glass is damaged or worn, direct contact with
the surface of the module may cause electric shock.
Do not damage the backsheet or glass of modules when fastening the modules to the bracket with
bolts.