Trumeter APM CT Meter User manual

APM
CT Meter
CAUTION: Risk of Danger
Read complete instructions prior to installation and
operation of the unit
CAUTION: Risk of electric shock
Before installation, read the Safety Warnings overleaf.
Intended Use: The APM has been specifically designed for engineers requiring an effective way to monitor and display
data. The APM accepts a range of electrical inputs (depending on the model) and displays the data on its integrated
multi-format display. The APM has been designed for installation into electrical cabinets or display panels. Output
models include two independent outputs that can be configured by the user to be either digital set-point outputs or
4-20mA monitor outputs.
DIP Switches
The DIP switches are on the back of the unit.
=Using external 5A secondary
current transformer
Sw Pos Measured Bar Graph Display Value
Item 1234 Value Min Max Format Max
1 0000 Custom (Defined in Software Application)
2 1000 Auto Ranging
3 0100 5 A 0 4 #.### 5.000
4 1100 5 A 0 5 #.### 5.000
5 0010 10 A 0 10 ##.## 10.00
6 1010 20 A 0 20 ##.## 20.00
7 0110 40 A 0 40 ##.## 40.00
8 1110 50 A 0 50 ##.## 50.00
9 0001 60 A 0 60 ###.# 60.0
10 1001 80 A 0 80 ###.# 80.0
11 0101 100 A 0 100 ###.# 100.0
12 1101 200 A 0 200 ###.# 200.0
13 0011 400 A 0 400 #### 400
14 1011 600 A 0 600 #### 600
15 0111 800 A 0 800 #### 800
16 1111 1000 A 0 1000 #### 1000
Use the DIP switch to set the CT Meter bar graph range,
and the current transformer (CT) ratio if used. The CT
ratio is shown as the target value. Use the software to set
other value CTs.
Operating specification
VALUE UNIT
INPUT
Input Range (CT Output
Current) 0-5 A I AC
Min CT Power (Burden) 1 VA
Input range (via external
current transformer) 0-10,000 A IAC
Input Current Frequency 45-65 Hz
Input Impedance 10 mΩ
Accuracy 0.5 %
Resolution 1 mA
Sample rate 8 KHz
Display modes RMS
Size
Wiring Diagram
68 x 68mm (2.68in) +0.7 -0mm Size of
the cutout in the panel:
CT METER
Using Current Transformer
The APM CT meter has been designed to be used with an external current
transformer. Never connect the meter directly to a live circuit.
Operating Specification
www. .com information@itm.com1.800.561.8187
Safety Warnings
WARNING: INSTALLATION AND MAINTENANCE MUST BE CARRIED
OUT BY SUITABLY QUALIFIED AND COMPETENT PERSONEL ONLY.
HAZARDOUS VOLTAGES MAY BE PRESENT ON THE CONNECTION
TERMINALS.
INSTALLATION
•Install this product in accordance with local regulations, codes and instructions.
•All fuses must be 0.5A / 250V Type F with a breaking capacity of 35A or greater.
•All conductors carrying hazardous voltage must have external switching or disconnect
mechanisms fitted that provide at least 3 mm of contact separation in all poles.
•Signal cables connected to this device must not exceed 30 metres long.
•If signal cables are routed outside the building, install extra surge-protection devices.
•Power supply, current input, USB and all outputs: Observe maximum allowable voltages.
All circuits connected to these connectors must be limited-energy and insulated by
double/reinforced insulation from mains voltages according to IEC 61010-1:2010
Failure to install or operate the unit in accordance with the above
requirements may impair the electrical safety of the unit.
Voltage measurements: An external UL recognized or listed
overcurrent protection device (fuse or circuit breaker) must be fitted
in-line with the voltage lead. Recommended fuse: 0.5A Type F with a
breaking capacity of 35A or greater. Fuse voltage rating must be
greater than the maximum voltage that will be applied to the meter.
MAINTENANCE
•Before cleaning, inspection or maintenance, isolate all power sources to the unit.
•There are no user-serviceable parts inside this unit. Never open the case.
•Inspect all external wiring connections at regular intervals. Replace any damaged wiring
and tighten any loose connections.
•To clean the unit, use a dry cloth to wipe the casing.
•Take great care connecting the supply. If you connect power to the wrong terminals, it may
destroy the unit.
Specification
Outputs When Powering APM from DC Supply
VALUE
4-20mA analogue output using setpoint 1. Using a diode-protected relay on setpoint 1.
Outputs when powering APM from AC supply Reset
When powering from an AC supply only connect isolated devices or other
APMs to the COM terminal
(in this application SP1 was configured as an analogue output using the APM Configurator)
Use the Reset input with the peak hold function
D
Environment Temperature - operating –10 to +60 deg C
Temperature - storage –40 to +70 deg C
Altitude 2000 metres
Relative Humidity (non-condensing) –Continuous 0 –85 %
Relative Humidity (non-condensing) - Intermittent 0 –95%
Pollution Degree (IEC664) 2
IP rating (from the front) IP65
NEMA Rating (from the front) Type 4 & Type 12
Vibration
Shock
Power supply Input 12-24V AC/DC +/-10%
Max Power 1.6W
Isolation None
Supply Frequency DC & 50-400 Hz
Display Number of digits 4
Digit height 12 mm
Number of bar-graph segments 40
Number of starburst message characters 4
Backlight colours Red, Green, White
LCD Positive or negative
Digit update frequency 0.08 –21 sec
Bar-graph update frequency 0.08 –21 sec
Viewing angle +/-70° Horizontal
+/-70° Vertical
Open Collector Outputs
Max voltage (open collector outputs) 34 V
Max current (open collector outputs) 500 mA
Analogue Output Output 4-20 mA
Accuracy 0.50 %
Resolution 0.02 mA
Connections Type Screw Terminals
Wire type Solid or Stranded
Min. cable temperature rating 65 deg C (149F)
Wire strip length 6.5mm to 7mm
(0.26” to 0.28”)
Wire gauge 0.8mm² - 3.3mm²
(18AWG to 12AWG)
Torque 0.5-0.6Nm
(4.42-5.31 lbf-in)
Certification CE
IEC 61010-1
In the Box APM
Getting started & safety guide
Gasket
Retaining clip
Panel Cut-out: 68 x 68 mm (2.68 in) +0.7 -0 mm (0.02
in). Max. panel thickness: 10 mm.
Dimensions: Depth behind panel inside front: 55mm
(2.17in) incl. external connections. Weight: 180 grams.
www. .com information@itm.com1.800.561.8187

This manual suits for next models

1

Other Trumeter Measuring Instrument manuals

Trumeter 924K User manual

Trumeter

Trumeter 924K User manual

Trumeter APM User manual

Trumeter

Trumeter APM User manual

Trumeter APM User manual

Trumeter

Trumeter APM User manual

Trumeter APM User manual

Trumeter

Trumeter APM User manual

Trumeter Shunt Series User manual

Trumeter

Trumeter Shunt Series User manual

Trumeter APM User manual

Trumeter

Trumeter APM User manual

Trumeter APM MAX-M21 User manual

Trumeter

Trumeter APM MAX-M21 User manual

Popular Measuring Instrument manuals by other brands

Teledyne ADFM Pro20 Installation and operation guide

Teledyne

Teledyne ADFM Pro20 Installation and operation guide

Universal Flow Monitors FlowStream OFS user manual

Universal Flow Monitors

Universal Flow Monitors FlowStream OFS user manual

Milwaukee Mi453 instruction manual

Milwaukee

Milwaukee Mi453 instruction manual

PCB Piezotronics J353B16 Installation and operating manual

PCB Piezotronics

PCB Piezotronics J353B16 Installation and operating manual

IET Labs SRC-10T-Tnetwork User and service manual

IET Labs

IET Labs SRC-10T-Tnetwork User and service manual

Trilithic 120 DSP Operation manuals

Trilithic

Trilithic 120 DSP Operation manuals

Kathrein MSK 200 manual

Kathrein

Kathrein MSK 200 manual

JB Prowler LD 5000 user manual

JB

JB Prowler LD 5000 user manual

YOKOGAWA 702907 user manual

YOKOGAWA

YOKOGAWA 702907 user manual

KAM LRW user manual

KAM

KAM LRW user manual

Fluke VT650 user manual

Fluke

Fluke VT650 user manual

METER TEROS 54 manual

METER

METER TEROS 54 manual

Omega FPR300 Series user guide

Omega

Omega FPR300 Series user guide

Ripley ODM DLS 355 quick start guide

Ripley

Ripley ODM DLS 355 quick start guide

Twinno T4055 operating manual

Twinno

Twinno T4055 operating manual

Gigahertz Solutions NFA 30M operating manual

Gigahertz Solutions

Gigahertz Solutions NFA 30M operating manual

Lippert Components Tire Linc quick start guide

Lippert Components

Lippert Components Tire Linc quick start guide

WIKA FLC-2300 operating instructions

WIKA

WIKA FLC-2300 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.