Heat TorchTM 050 Quick Guide
www.farnam-custom.com
Heat TorchTM 050 Quick Guide
Product Descripon
Tutco-Farnam’s Heat TorchTM inline air heaters are ideal for
rapidly heang air. Industrial strength open coil heaters provide
ecient heat transfer through direct heang element contact
with the airow
Operaon
To operate this heater, ensure air is owing and ener-
gize the main supply disconnect. Set the controlling
device to the desired temperature.
During inial heang, it is recommended to slowly
ramp up the process set point and inspect the heang
system for problems.
DO NOT operate the heater at voltages higher than the
recommended use.
DO NOT operate the heater at ow rates below the
minimum ow range (1 SCFM)—reduced ow can
shorten heater life.
Supply clean, dry air to the heater at a max of 120 psi .
CAUTION
Tutco-Farnam Custom Products recommends
installaon be performed by qualied personnel
familiar with the Naonal Electrical Code and all
local codes and standards. It is the responsibility
of the installer to verify the safety and suitability
of the installaon.
Failure to follow Tutco-Farnam’s recommenda-
ons could result in premature failure, serious
equipment damage, injury or death.
WARNING
DO NOT mount heaters in an atmosphere containing combusble gases,
vapors, dusts or bers.
Hazardous voltages are present in this equipment. Lock out and tag the
branch circuit disconnect switch before working on this heater.
Exterior of heater at exhaust is approximately the air temperature. Treat the
exterior of the heater as a burn hazard.
Typical causes for uneven airow are structural components blocking air or
mounng the heater too close to elbows, transions or the fan/blower.
REV A 9/18/15
Wiring your Heat Torch 050
Simply connect the white leads to single phase power at the
specied voltage.
Electrical Interlock
Tutco-Farnam Custom Products strongly recommends the
use of an electrical interlock with the air source—this helps
ensure that the heater will not run without air.