In order to function properly, SkyLite V3.1 must be
connected to a dimmable driver/ballast.
NOTE: Some dimmable drivers/ballasts must be
programmed/set to dimmable mode. If this has not been
done, SkyLite V3.1 will not be able to dim the connected
luminaire.
ATTENTION:
TVILIGHT PROJECTS BV / Beechavenue 162-180, 1119 PS, Schiphol-Rijk, the Netherlands

PR161826 | Rev. I | Page 3 of 15
3. Factory Installation of SkyLite v3.1 into the Luminaire.............page 6
1. In Box........................................................................................................page 5
2. You Will Need........................................................................................page 5
4. Field Installation of a Luminaire with SkyLite v3.1...................page 13
5. Wiring Diagram...................................................................................page 16
When installing SkyLite v3.1 in a Luminaire.
What you will find in the Box.
Tools you will need for SkyLite v3.1 installation.
Installing a Luminaire with SkyLite v3.1.
Wiring diagram for connecting the SkyLite v3.1 to the Driver.
INDEX

PR161826 | Rev. I | Page 4 of 15
1. In Box
2. You Will Need
Screw Driver M3 Screw
Scan&Go App
Available in the
Apple App Store
and in the
Google Play Store
Drill
10.5 mm
drillbit
Pole Label
TVI-SKLMP-A031I-A01-002644
DEMODEMO
DEMODEMO
SkyLite V3.1
30
105
105
7.5
17 33.510.75
55
120
3.5
4.2
14
26
External Antenna
Nut
50 cm
Cable Assembly
29 cm

PR161826 | Rev. I | Page 5 of 15
3.1. Open Luminaire
3.2. Access Mounting Plate
3. Factory Installation of SkyLite v3.1
into the Luminaire

PR161826 | Rev. I | Page 6 of 15
3.3. Drill 10.5 mm hole in top of the Luminaire
3.4. Place Antenna through hole
Note: For added protection against rust, the use of an anti-corrosion spray such as WD40
Corrosion inhibitor or equal is recommended.
Remove adhesive backing prior to placement.

PR161826 | Rev. I | Page 7 of 15
3.5. Tighten Antenna using Antenna Nut
Tighten the Antenna nut with a max. torque of 1.5 Nm.
3.6. Place SkyLite V3.1 on Mounting Plate
Screw into place. ATTENTION: Observe precautions for the
handling of electrostatic sensitive devices.

PR161826 | Rev. I | Page 8 of 15
3.8. Connect Antenna to SkyLite V3.1
Tighten SMA connector with a torque of 0.8 Nm (finger
tight). ATTENTION: Observe precautions for the handling
of electrostatic sensitive devices.
3.7. Connect Cable Assembly
ATTENTION: Observe precautions for the handling of
electrostatic sensitive devices.

PR161826 | Rev. I | Page 9 of 15
3.9. Connect SkyLite v3.1 to Driver
ATTENTION: Observe precautions for the handling of
electrostatic sensitive devices.
Note: Wiring Diagram can be found in Section 5.
After connecting
SkyLite to Driver
there is a risk of
electric shock
from the antenna
connector. Do
not touch while
powered.

PR161826 | Rev. I | Page 10 of 15
3.10. Return Mounting Plate to closed position
and close Luminaire
3.11. Attach the Pole Label to the Luminaire
with a piece of tape
TVILIGHT
www.tvilight.com
TVI-CSP1-01-0014
Note: This placement of the Pole Label is temporary until field installation of the
Luminaire. The label should not be placed loose in the box and should not fall out or
under the Luminaire when it is in the box.

PR161826 | Rev. I | Page 11 of 15
3.12. Put the Luminaire in the box for shipment
TVILIGHT
www.tvilight.com
TVI-CSP1-01-0014

PR161826 | Rev. I | Page 12 of 15
4. Field Installation of the Luminaire
4.1. You will find the Luminaire with Pole label
attached
4.2 Remove the sticker from the Luminaire and
install the Luminaire onto the Pole
TVILIGHT
www.tvilight.com
TVI-CSP1-01-0014

PR161826 | Rev. I | Page 13 of 15
4.3. Apply product ID sticker to the pole once
the Luminaire is installed
SAME
STICKER
TVILIGHT
www.tvilight.com
TVI-CSP1-01-0014
TVILIGHT
www.tvilight.com
TVI-CSP1-01-0014
TVILIGHT
www.tvilight.com
TVI-CSP1-01-0014
DEMODEMO
DEMODEMO
TVI-SKLMP-A031I-A01-002644

PR161826 | Rev. I | Page 14 of 15
www.tvilight.com
TVI-SKLEXT1-01-0014
www.tvilight.com
TVI-SKLMP-A031I-A01-002644
4.4 Add device to CityManager
1. Download Tvilight Scan&Go from Apple iOS App Store or from Google Play
Store.
2. Login with your Username and Password.
3. Use the ‘Add device’ function in Scan&Go app to add the device to
CityManager.
4. The location of the new device is determined by Scan&Go’s GPS and it will
be indicated on the map.
5. The Device Serial Number will be added when scanning the QR-Code with
the camera.
6. Fill in the required fields (the ones with an asterisk), select the device type
and also select the type of ballast (PWM or DALI-Logarithmic or DALI-
Linear).
Note: The type of ballast must be known before installation.
7. Press save and move to next device.
For more information on how to use Scan&Go app, please visit:
https://www.tvilight.com/scan-go/

PR161826 | Rev. I | Page 15 of 15
5. Wiring Diagram
GREY
0-10V-
or
DALI-
BLUE
N
BROWN
L
GREEN
GND
BLACK
0-10V+
or
DALI+
To Armature
To Mains
TVILIGHT
SKYLITE V3.1
GND NL
Driver
GND N L
0-10V-
or
DALI-
0-10V+
or
DALI+
0-10V-
or
DALI-
0-10V+
or
DALI+ N L
WARNING:
If not correctly connected product might not
function or it might be permanently damaged.
Note: For added protection, an external circuit breaker at the power
input of the product is recommended. Circuit breakers such as
the ELeQ LS-94 5L2408 or similar rated products are acceptable.