PSX-D8 and PSX-D8P INSTALLATION MANUAL 2
PSX-D8, D8P – Accessory Overview
+ –
OUT1
+ –
OUT2
+ –
OUT3
+ –
OUT4
+ –
OUT5
+ –
OUT6
+ –
OUT7
+ –
OUT8
JP1
2
B1
B2
BR
B1
B2
BR
F1
F2
F3
F4
F5
F6
F7
F8
1
JP2
2 1
JP3
2 1
JP4
2 1
JP5
2 1
JP6
2 1
JP7
2 1
JP8
2 1
FLEXIOFLEXIO
FLEXIOFLEXIOFLEXIOFLEXIO PSX-D8
1
FlexIO Connectors
These connectors pass the FlexIO buss through the
PSX-D8/D8P to other accessory boards in the system.
2
B1 Connectors (J1 & J4)
These fastons are for connection to the B1 voltage buss
in the system. The voltage on the B1 buss comes from
the DC1 faston of a PSX power supply. This voltage
will be directed to any outputs whose Output Selection
Jumper is set in the B1 position.
3
B2 Connectors (J3 & J5)
These fastons are for connection to the B2 voltage buss
in the system. The voltage on the B2 buss comes from
the DC1 faston of a PSX power supply in a dual voltage
system. This voltage will be directed to any outputs whose
Output Selection Jumper is set in the B2 position.
If the PSX-D8/D8P is being used in a single voltage sys-
tem, these fastons can either be left unused or connected
to the PSX Power Supply’s DC2 output, to provide FAI con-
trol to outputs selected for B2.
4
BR Connectors (J2 & J6)
The DC Common buss in the system. All boards in the
system must have their BR fastons wired together for
proper operation.
5
Output Selection Jumpers (JP1 – JP8)
These jumpers select which voltage buss input is select-
ed for the output. Jumper numbers correspond with the
zone number (e.g. JP1 is the jumper for OUT1). Possible
settings are as follows:
• Position 2 (Left) – B2 Buss
• Position 1 (Right) – B1 Buss
• Removed – Disable Output
6
Output Fuses (F1 – F8) – Optional
When using the fused version of the board, these are
the fuses for each zone output. Fuse numbers corre-
spond with the zone number (e.g. F1 is the fuse for OUT1).
When using the PTC version of the board, the fuse will
be replaced with a soldered-in PTC.
7
Zone Outputs (Out1 – Out8)
These are the zone output terminal strips. These ter-
minal strips are removable and accept wire sizes from
AWG14 – AWG22. The terminals are labeled on the PC
board underneath the terminal strip.
I
CAUTION When powering magnetic loads such as
maglocks, door strikes, solenoids, etc, each of these
loads must have a reverse protection diode either built-in
or external to the device.
8
Output LEDs (D1 – D8) – Green
These LEDs indicate the availability of voltage on a
zone’s output. When voltage is available on the output
terminals, the LED is lit. LED numbers correspond with
the zone number (e.g. D1 is the LED for OUT1).
Connections to the module shall be
completed within the same room,
not exceeding a length of 100 ft.
Class 2 power limited wiring must be
seperated from non-power limited wiring
by a minimum of 1/4 inch and must use
seperate knockouts
• The installation and all wiring methods
shall be in accordance with ANSI/NFPA70
and all local codes.
For ULC compliance, installation and all
wiring methods shall be in accordance
with the Canadian Electrical Code, C22.1,
Part I, Section 32