Tyco Visonic TOWER-30AM PG2 User manual

D-303372 TOWER-30AM PG2, TOWER-30AM K9-40 PG2 Installation Instructions 1
TOWER-30AM PG2 /
TOWER-30AM K9-40 PG2
WirelessPowerGHigh‐securityMirrorDetectorwithAnti‐
masking
Installation Instructions
1. INTRODUCTION
The TOWER-30AM PG2 and TOWER-30AM K9-40 PG2 (pet-immune) are 2-way, microprocessor-
controlled, wireless digital mirror PIR detectors which include the following features:
For use with all PowerMaster® control panels (version 13 and higher).
Adaptive Active Infra-Red Anti-Masking technology providing the most advanced reliable protection against
intentional masking attempts (patent pending)
Includes a fully supervised PowerG transceiver.
Incorporates patent pending black mirrors for extremely high white light immunity.
Advanced elliptical / parabolic mirror technology (patented)
V-slot® optic technology (patented) for improved robustness, anti-vandalism and for very high
reliability.
Creep zone protection
TOWER-30AM K9-40 PG2 can distinguish between human beings and pets weighing up to 18 kg (40 lb)
The advanced True Motion Recognition™ algorithm (patented) allows distinguishing between the true
motion of an intruder and any other disturbances which may cause false alarms.
Built-in link quality indicators; no need for the installer to physically approach the control panel thus
making installation faster and easier.
No vertical adjustment is needed.
Motion event counter determines whether 1 or 2 consecutive motion events will trigger an alarm.
Automatic termination of walk-test after 15 minutes.
Microprocessor-controlled temperature compensation.
Sealed chamber protects the optical system.
Front and back tamper protection.
Self-test
Note: The pet immunity and creep zone protection were not evaluated by UL.
C
B
A
A. Screw cover
B. LED
C. PIR optical window
Figure 1. General View
2. INSTALLATION
2.1 General Guidance (see Fig. 2)
1. Keep away from heat sources.
2. Do not expose to air drafts.
3. Do not install outdoors.
4. Avoid direct sunshine.
5. Keep wiring away from power cables.
6. Do not install behind partitions.
7. Mount on solid stable surface.
Installed in accordance with NEC, NFPA 70.
Installed in accordance with UL 681, Standard
for Installations and Classifications of burglar
and Holdup Alarm Systems.
Installed in accordance with C22.1, Canadian
Electrical Code, Part I, Safety Standard for
Electrical Installations
1 2 3
4 5 6
7
Figure 2. General Guidelines
Important! The detector is immune to 18 kg (40 lb) animals moving on the floor or climbing on furniture as long as the
activity takes place below 1 m (3 ft). Above the 1 m (3 ft) height limit, the detector is immune to 9 kg (20 lb) pets, but the
pet immunity will decrease as the pet gets closer to the detector. It is therefore recommended to select a mounting location
that minimizes potential close proximity of animals.
WARNING! To comply with FCC and IC RF exposure compliance requirements, the PIR detector should be located at a distance of at least 20
cm from all persons during normal operation. The antennas used for this product must not be co-located or operated in conjunction with any other
antenna or transmitter

2 D-303372 TOWER-30AM PG2, TOWER-30AM K9-40 PG2 Installation Instructions
2.2 Mounting
Notes:
1. Mount the detector so that its orientation is perpendicular to the expected intrusion path.
2. For installations of detector at 2m high, Dead zone is 2ft at 0m high and 0.5ft at 1.5m high.
1
2
1. On the indicated location, lift the screw cover upward using your
thumb.
2. Release the screw and open the cover in the direction
shown by the arrow.
3
3. Insert a screwdriver into the slot and then push inward to separate the base from the cover.
4
a
b
C
a
b
C
Note: For the desired detector's range and height, use mounting
holes
a
or
b
, as specified in the table.
6 1.8
7 2.1
8 2.4
9 2.7
10 3.0
ft m
b
a
b
b
a
a
b
b
a
a
a
b
b
b
b
b
15
6
30
9
45
12
60 ft
15 m
A
B
a – upper surface (without downward tilt)
b – lower surface (with downward tilt)
4. Set the desired detector range.
A. Mounting height
B. Coverage range
C. Break-away base segment (shaded)

D-303372 TOWER-30AM PG2, TOWER-30AM K9-40 PG2 Installation Instructions 3
5
6
D
E
F
5. Insert battery while observing polarity.
D. Enroll button (use a screwdriver to press the recessed button)
E. Battery
F. Tamper switch
CAUTION! THE BACK TAMPER SWITCH WILL NOT PROTECT THE UNIT UNLESS THE BREAK-AWAY BASE SEGMENT IS
SECURED TO THE WALL WITH AT LEAST ONE SCREW.
CAUTION! RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERY
ACCORDING TO MANUFACTURER'S INSTRUCTIONS.
Note: Back Tamper must be enabled for UL installations.
Figure 3. Mounting
2.3. Enrollment
Refer to the PowerMaster control panel's Installer Guide and follow the procedure under the "02:ZONES/DEVICES"option of the
Installer Menu. A general description of the procedure is provided in the following flow chart.
Step 1 Step 2 Step 3 Step 4 Step 5 Step 6
Enter the Installer menu
and select
“02:ZONES/DEVICES”
Select "ADD NEW
DEVICE" Option
See Note [1]
Enroll the device or Enter
the device ID
Select the desired Zone
Number
Configure
Location, Zone
Type & Chime
Parameters
Configur
e the
Detector
means scroll and select
See Note
[2]
Notes:
[1] If the detector is already enrolled you can configure the detector parameters via the “Modify Devices” option – see Step 2.
[2] Select the "Device Settings" option and refer to section 2.4 to configure the detector parameters.
2.4. Configuring the Detector Parameters
Enter the menu and follow the configuration instructions for the TOWER-30AM PG2 PIR detector as described in
the following table.
Option Configuration Instructions
Define whether or not the alarm LED indication will be activated.
Optional settings: LED ON (default) and LED OFF.
Define whether an alarm will be activated upon continued motion (low sensitivity) or upon a single alarm event
(high sensitivity).
Optional settings: LOW sensitive (default) and HIGH sensitive.
E
vent Counter
A
larm LED
D
EVICE SETTINGS
Z
14.
D
EV SETTINGS
Z
14.
S
ET CHIME
Z
14.
Z
ONE TYPE
Z
14.
L
OCATION
ID No. 123
-
X
XXX
Z
14:
M
otion Sens
E
NTR ID:XXX
-
X
XXX
E
NROLL NOW or
M
ODIFY DEVICES
A
DD NEW DEVICES
0
2.ZONES/DEVICES

4 D-303372 TOWER-30AM PG2, TOWER-30AM K9-40 PG2 Installation Instructions
Define whether or not to set the activity time during disarm.
Optional settings: NOT Active (default), YES – no delay, YES + 5s delay, YES + 15s delay,YES + 30s
delay,YES + 1m delay,YES + 2m delay, YES + 5m delay,YES + 10m delay,YES + 20m delay and
YES + 60m delay.
Define the activity and the sensitivity level of the anti-masking.
Optional settings: LOW sensitive (default), HIGH sensitive and disabled.
3. LOCAL DIAGNOSTICS TEST
NOTE: Run a diagnostic test at least once a year to ensure that the detector is working correctly.
A. Separate the base from the cover (see Fig. 3).
B. Put back the cover to return the tamper switch to its normal (undisturbed) position, and then secure the front cover to the base with the
case closure screw.
C. The TOWER-30AM PG2 will enter a 2 min. stability period. During this time the red LED blinks.
D. Walk-test the coverage area - see Figure 4. Walk across the far end of coverage pattern in both directions; the red LED lights each
time your motion is detected followed by 3 LED blinks.
The following table indicates the received signal strength indication.
LED response Reception
Green LED blinks Strong
Orange LED blinks Good
Red LED blinks Poor
No blinks No communication
IMPORTANT! Reliable reception must be assured. Therefore, "poor" signal strength is not acceptable. If you receive a "poor" signal
from the detector, re-locate it and re-test until a "good" or "strong" signal strength is received (in regions requiring UL-compliant
installation, only “strong” signal strength is permitted).
1. For detailed Diagnostics Test instructions refer to the control panel Installer Guide.
2. For UL/CUL installations, the test result must be “Strong”.
4. EVENT INDICATIONS
LED Indications Event
Red LED blinks Stabilization (warm-up 120 sec)
Red LED ON 0.2 sec. Tamper open / close
Red on 2 sec. Intruder alarm
Yellow LED on AM detection – diagnostic mode
Yellow LED blinks slowly (0.2 sec. ON, 30 sec. OFF) AM detection – Normal mode
Yellow and red LED blink simultaneously (0.2 sec. ON [both], 0.2 sec. OFF) Self-test failure – Diagnostic mode
Yellow and red LED blink simultaneously slowly (0.2 sec. ON [both], 30 sec. OFF) Self-test failure – Normal mode
5. SPECIAL COMMENTS
Even the most sophisticated detectors can sometimes be defeated or may fail to warn due to: DC power failure / improper connection,
malicious masking of the lens, tampering with the optical system, decreased sensitivity in ambient temperatures close to that of the
human body and unexpected failure of a component part.
The above list includes the most common reasons for failure to detect intrusion, but is by no means comprehensive. It is therefore
recommended that the detector and the entire alarm system be checked weekly, to ensure proper performance.
An alarm system should not be regarded as a substitute for insurance. Home and property owners or renters should be prudent enough
to continue insuring their lives and property, even though they are protected by an alarm system.
6. COMPLIANCE WITH STANDARDS
Compliance with Standards
Europe (CE): EN 50131-1, EN 300220, EN 301489, EN 60950, EN 50130-4, EN 50130-5,
EN 50131-2-2 Grade 3 Class II, EN 50131-6
The TOWER-30 AM PG2 and TOWER-30 AM K9-40 PG2 are compatible with the RTTE requirements -
Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999.
Certified by the Dutch testing and certification body Telefication BV to the following standards :
EN 50131-2-2, EN 50131-6, EN 50131-5-3, EN 50130-4, and EN 50130-5.
Telefication BV has certified only the 868 MHz variant of this product.
UK: This product is suitable for use in systems installed to conform to PD6662:2010 in accordance
with EN 50131-2-2 security Grade 3 and environmental Class 2. DD243 and BS8243
USA: CFR 47 Part 15 (FCC)
Canada: RSS 210
A
NTI MASKING
-
A
M
D
ISARM
A
ctivity

D-303372 TOWER-30AM PG2, TOWER-30AM K9-40 PG2 Installation Instructions 5
The Power G peripheral devices have two- way communication functionality, providing additional benefits as described in
the technical brochure. This functionality has not been tested to comply with the respective technical requirements and
should therefore be considered outside the scope of the product’s certification.
EN 50131-1 Security Grade According to EN 50131-1:2006 and A1:2009, this equipment can be applied in installed systems up to
and including Security Grade 2.
EN 50131-1 Environmental
Class
Class II
FCC Compliance Statement
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates
uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio and television reception.
However, there is no guarantee that interference will not occur in a particular installation. If this device does cause such interference,
which can be verified by turning the device off and on, the user is encouraged to eliminate the interference by one or more of the
following measures:
– Re-orient or re-locate the receiving antenna.
– Increase the distance between the device and the receiver.
– Connect the device to an outlet on a circuit different from the one that supplies power to the receiver.
– Consult the dealer or an experienced radio/TV technician.
WARNING! Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
This device complies with FCC Rules Part 15 and with Industry Canada licence-exempt RSS standard(s). Operation is subject to two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference that may be received
or that may cause undesired operation.
Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est
autorisee aux deux conditions suivantes :(1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter
tout brouillage radioelectrique subi, meme si le brouillage est susceptible d'en compromettre le fonctionnement.
The technical documentation as required by the European Conformity Assessment procedure is kept at:
UNIT 6 MADINGLEY COURT CHIPPENHAM DRIVE KINGSTON MILTON KEYNES MK10 0BZ. TEL.: +44(0)845 0755800 FAX: +44(0)845 0755801
W.E.E.E. Product Recycling Declaration
For information regarding the recycling of this product you must contact the company from which you orignially purchased it. If you are discarding this product and not
returning it for repair then you must ensure that it is returned as identified by your supplier. This product is not to be thrown away with everyday waste.
Directive 2002/96/EC Waste Electrical and Electronic Equipment.
APPENDIX: SPECIFICATIONS
GENERAL
Detector T
y
pe Dual element low-noise p
y
roelectric senso
r
Mirro
r
Data No. of Beam Elements: No. of Beam Elements:
18x3=54 far parabolic mirror segments 2x3 = 6 powerful mirror segments
Note: Window material is High Density Polyethylene (HDPE). The window is part of the
Enclosure Cover
(
Item 1
)
.
Max. Covera
g
e 15 m
(
49 ft
)
/ 90°
A. Horizontal view
B. Vertical view
Fi
g
ure 4. Covera
g
e Pattern & Wal
k
-
test
Pet Immunit
y
(
onl
y)
Up to 18 k
g
(
40 lb
)
ELECTRICAL
Power Suppl
y
T
y
pe C
Internal Battery 3V Lithium battery, type CR-123A or equivalent (optionally can be used type CR17450)
Notes:
1. Use only the above battery type.
2. For UL installations use Gold Peak
(
GP
)
CR123A onl
y
.
Nominal Batter
y
Capacit
y
1450 mA/h
(
2400mA/h for optional CR17450
)
Low Batter
y
Threshold 2.45 V

6 D-303372 TOWER-30AM PG2, TOWER-30AM K9-40 PG2 Installation Instructions
Batter
y
Life
(
for t
y
pical use
)
6.5
y
ears
FUNCTIONAL
True Motion Event Verification 2 remote selections - 1
(
OFF
)
or 2
(
ON
)
motion events
Alarm Period 2 seconds
WIRELESS
Frequenc
y
Band
(
MHz
)
Europe and rest of world: 433-434, 868-869 USA: 912-919
Communication Protocol PowerG
Supervision Si
g
nalin
g
at 4-min. intervals
Tamper Alert Reported when a tamper event occurs and in any subsequent message, until the tamper
switch is restored
MOUNTING
Height 1.8 – 3.0 m (6 - 10 ft).
Installation Options Surface or corner
ACCESSORIES BR-1: Surface mounted swivel bracket, adjustable 30° down and 45° left/45° right.
BR-2: BR-1 with a corner adapter
BR-3: BR-1 with a ceiling adapter
Note: UL did not evaluate the product with the use of the BR brackets
ENVIRONMENTAL
RFI Protection >20 V/m up to 2000 MHz, excludin
g
inband frequencies
Operating Temperatures -10°C to 50°C (14°F to 122°F) indoo
r
Note: UL tested 0°C to 49°C
Stora
g
e Temperatures -20°C to 60°C
(
-4°F to 140°F
)
Humidity Average relative humidity of up to approximately 75% non-condensing. For 30 days per
year the relative humidity may vary between 85 % and 95 % non-condensing
Note: For UL installations, relative humidit
y
is 85%.
PHYSICAL
Size
(
H x W x D
)
115 x 60 x 48 mm
(
4-1/2 x 2-5/16 x 1-15/16”
)
Wei
g
ht
(
with batter
y)
90
g
(
3 oz
)
.
Colo
r
White
PATENTS U.S. Patents 5,693,943 6,211,522 D445,709
(
another patent pendin
g)
WARRANTY
Visonic Limited (the “Manufacturer") warrants this product only (the "Product") to the original purchaser only (the
“Purchaser”) against defective workmanship and materials under normal use of the Product for a period of twelve
(12) months from the date of shipment by the Manufacturer.
This Warranty is absolutely conditional upon the Product having been properly installed, maintained and operated
under conditions of normal use in accordance with the Manufacturers recommended installation and operation
instructions. Products which have become defective for any other reason, according to the Manufacturers
discretion, such as improper installation, failure to follow recommended installation and operational instructions,
neglect, willful damage, misuse or vandalism, accidental damage, alteration or tampering, or repair by anyone
other than the manufacturer, are not covered by this Warranty.
The Manufacturer does not represent that this Product may not be compromised and/or circumvented or that the
Product will prevent any death and/or personal injury and/or damage to property resulting from burglary, robbery,
fire or otherwise, or that the Product will in all cases provide adequate warning or protection. The Product,
properly installed and maintained, only reduces the risk of such events without warning and it is not a guarantee
or insurance that such events will not occur.
THIS WARRANTY IS EXCLUSIVE AND EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, OBLIGATIONS
OR LIABILITIES, WHETHER WRITTEN, ORAL, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, OR OTHERWISE. IN NO CASE SHALL
THE MANUFACTURER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES
FOR BREACH OF THIS WARRANTY OR ANY OTHER WARRANTIES WHATSOEVER, AS AFORESAID.
THE MANUFACTURER SHALL IN NO EVENT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL,
CONSEQUENTIAL OR PUNITIVE DAMAGES OR FOR LOSS, DAMAGE, OR EXPENSE, INCLUDING LOSS
OF USE, PROFITS, REVENUE, OR GOODWILL, DIRECTLY OR INDIRECTLY ARISING FROM
PURCHASER’S USE OR INABILITY TO USE THE PRODUCT, OR FOR LOSS OR DESTRUCTION OF
OTHER PROPERTY OR FROM ANY OTHER CAUSE, EVEN IF MANUFACTURER HAS BEEN ADVISED OF
THE POSSIBILITY OF SUCH DAMAGE.
THE MANUFACTURER SHALL HAVE NO LIABILITY FOR ANY DEATH, PERSONAL AND/OR BODILY
INJURY AND/OR DAMAGE TO PROPERTY OR OTHER LOSS WHETHER DIRECT, INDIRECT, INCIDENTAL,
CONSEQUENTIAL OR OTHERWISE, BASED ON A CLAIM THAT THE PRODUCT FAILED TO FUNCTION.
However, if the Manufacturer is held liable, whether directly or indirectly, for any loss or damage arising under this
limited warranty, THE MANUFACTURER'S MAXIMUM LIABILITY (IF ANY) SHALL NOT IN ANY CASE
EXCEED THE PURCHASE PRICE OF THE PRODUCT, which shall be fixed as liquidated damages and not as a
penalty, and shall be the complete and exclusive remedy against the Manufacturer.
When accepting the delivery of the Product, the Purchaser agrees to the said conditions of sale and warranty and
he recognizes having been informed of.
Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so these
limitations may not apply under certain circumstances.
The Manufacturer shall be under no liability whatsoever arising out of the corruption and/or malfunctioning of any
telecommunication or electronic equipment or any programs.
The Manufacturers obligations under this Warranty are limited solely to repair and/or replace at the
Manufacturer’s discretion any Product or part thereof that may prove defective. Any repair and/or replacement
shall not extend the original Warranty period. The Manufacturer shall not be responsible for dismantling and/or
reinstallation costs. To exercise this Warranty the Product must be returned to the Manufacturer freight pre-paid
and insured. All freight and insurance costs are the responsibility of the Purchaser and are not included in this
Warranty.
This warranty shall not be modified, varied or extended, and the Manufacturer does not authorize any person to
act on its behalf in the modification, variation or extension of this warranty. This warranty shall apply to the
Product only. All products, accessories or attachments of others used in conjunction with the Product, including
batteries, shall be covered solely by their own warranty, if any. The Manufacturer shall not be liable for any
damage or loss whatsoever, whether directly, indirectly, incidentally, consequentially or otherwise, caused by the
malfunction of the Product due to products, accessories, or attachments of others, including batteries, used in
conjunction with the Products. This Warranty is exclusive to the original Purchaser and is not assignable.
This Warranty is in addition to and does not affect your legal rights. Any provision in this warranty which is
contrary to the Law in the state or country were the Product is supplied shall not apply.
Warning: The user must follow the Manufacturer’s installation and operational instructions including testing the
Product and its whole system at least once a week and to take all necessary precautions for his/her safety and
the protection of his/her property.
1/08
EMAIL: info@visonic.com
INTERNET: www.visonic.com
VISONIC LTD. 2013 D-303372 TOWER-30AM PG2, TOWER-30AM K9-40 PG2 (REV. 2, 3/13)
This manual suits for next models
1
Table of contents
Other Tyco Security Sensor manuals

Tyco
Tyco 614 Series Manual

Tyco
Tyco FV300 SERIES User manual

Tyco
Tyco TOWER-20AM User manual

Tyco
Tyco MX-862 User manual

Tyco
Tyco PowerG PG9936H User manual

Tyco
Tyco DSC PowerSeries PC1616 Manual

Tyco
Tyco BLAZEMASTER CPVC User manual

Tyco
Tyco DSC WS8904P User manual

Tyco
Tyco WS4933 Series User manual

Tyco
Tyco Visonic TOWER-30AMPG2 User manual

Tyco
Tyco MX Technology 801Ex Series Manual

Tyco
Tyco WS4933 Series User manual

Tyco
Tyco Visonic SMD-429 PG2 Series User manual

Tyco
Tyco SD-304C PG2 User manual

Tyco
Tyco Visonic PowerG NEXT CAM PG2 User manual

Tyco
Tyco Visonic SD-304C PG2 User manual

Tyco
Tyco FC410DIM User manual

Tyco
Tyco Visonic TOWER-20 PG2 User manual