The TOWER 20 AM PG2 is a 2-way, wireless outdoor digital mirror PIR detector which includes the following features:
lPatented 8 independent quad PIR detectors (Octa-QUADTM) operating in true Quad configuration (patented) with true motion recognition (TMR)
processing for each of the 8 PIR detectors, as well as central motion processing that distinguishes between moving intruders and trees and bushes
in motion.
lAdvanced Obsidian Black MirrorTM optics (patent pending).
lOptimum performance even in poor weather conditions such as snow, rain, dust, wind and direct sunlight
lTamper protection prevents opening and removal from wall
lPowerG two-way Frequency Hopping Spread Spectrum FHSS-TDMA technology - provides robustness and reliability that is closer than ever to
wired systems
lBuilt-in link quality indicators enable installer to check signal quality without physically approaching the control
panel, thus making installation faster and easier.
lRobust housing with recessed window.
lSmart anti masking distinguishes between masking spray and rain.
lAlarm LED is visible in sunlight.
lAutomatic termination of walk-test after 15 minutes.
lMicroprocessor-controlled temperature compensation.
lImmunity to pets weighing up to 18 Kg (40lb), not pet alley – see Table 1
lBuilt-in swivel bracket
Figure 1.
General View
2. INSTALLATION
2.1. Installation
A. Bracket installation (see Figure 2). Fix the bracket firmly on a stable wall or pillar. The orientation of the fixed bracket must be as parallel as possible
to the surveyed ground surface.
B. Adjust the detector's horizontal and vertical angles (see Figure 3), according to the surveyed ground surface. The vertical angle indicator position
for various installation height and coverage distance combinations is detailed in Table 1 (the information refers to a relatively flat surveyed area.
Verify the correct installation by walk-test).
C. Fasten the detector to the bracket (see Figure 2 step 4).
Table 1 - Vertical Adjustment Reference
Mounting Height Coverage Distance
2m / 6.7ft 4m / 13ft 6m / 20ft 8m / 26ft 10m / 33 ft 12m / 39 ft
3.0m / 10 ft - 1 2 2 3 3
2.5m / 8 ft 1 1 2 3 4 4
2.0m / 7 ft 1 2 3 4 5 5
1.5m / 5 ft 2 3 4 5 5 -
Note: The grayed-in cells in Table 1 are the installation alternatives recommended for further reducing false alarms from pets.
TOWER-20AM PG2
PowerG Outdoor mirror PIR motion detector with anti-masking and built-in
camera Installation Instructions

Correct Installation
Incorrect Installation
Callout Description
AMark drilling point
BFor wall tamper
CDrill
DFasten
Note: The 2 screw holes enable adjustment of the bracket on the wall if required after testing.
EThree long screw
FTwo short screws
Figure 2 - Installation
HORIZONTAL ADJUSTMENT (-45° to +45°)
D-304046 TOWER-20 PG2 Installation Instructions 2

VERTICAL ADJUSTMENT (0° to -10° in 2.5° clicks / steps)
COVER CLOSURE
Step Description Step Description
1Release locking 6Lock
2Adjust 7Turn cover and push
3Lock 8Put back cover
4Release locking 9Put back cover and secure with screw
5Adjust 10
Figure 3 - Adjustment and Cover Closure
Installation Notes:
Do not obscure the detector field of view with large objects.
2.2. Battery Insertion
It is recommended to perform the first batteries insertion on a flat surface (see Figure 4). After battery insertion, the LED will flash for 60 seconds and
then the detector will enter a 15 minutes' local diagnostic mode.
A. Tamper switch B. Press firmly to release the bracket C. 3 screws
Figure 4 – Battery Insertion
D-304046 TOWER-20 PG2 Installation Instructions 3

2.3. Enrollment
Refer to the PowerMaster control panel's Installer Guide and follow the procedure under the "02:ZONES/DEVICES" option of the Installer Menu.
Ageneral description of the procedure is provided in the following flow chart.
Step 1 Step 2 Step 3 Step 4
Enter the Installer menu and select
“02:ZONES/DEVICES”
Select "ADD NEW DEVICE"
See Note 1
Enroll the device (see Figure 5) or
enter the device ID
Select a detector number for the
new detector
02:ZONES/DEVICES ðADD NEW DEVICES
6
ðENROLL NOW or
ENTR ID:XXX-XXXX
ðZ0x:Motion Sens
ID No. 130-XXXX
ð
MODIFY DEVICES
Step 5 Step 6 Step 7
Configure Location, Zone Type &
Chime parameters
Enter PARTITIONS.
See Note 2
Assign partitions to the detector by
pressing the ,
and/or buttons on the
panel
Z0x.LOCATION
Z0x.ZONE TYPE
Z0x.SET CHIME
ðZ0x.PARTITIONS ðZ0x:P1n-- P2....P3n
ðmeans scroll wwand select OK.
Notes:
[1] If the detector is already enrolled you can configure the detector parameters and assign partitions via the “Modify Devices” option – see Step 2.
[2] PARTITIONS will appear only if PARTITIONING was previously enabled in a panel that supports the Partitioning feature (for further details, see
"Partitioning" in the PowerMaster Installer Guide).
2.4. Configuring the Detector Parameters
Enter the DEVICE SETTINGS menu and follow the configuration instructions for the TOWER 20 AM PG2 PIR detector as described below.
Option Configuration Instructions
ALARM LED Define whether or not to activate the alarm LED indication.
Optional settings: ON (default) and OFF.
PIR
SENSITIVITY
Define if the detector operates at regular or high PIR sensitivity, or that at least one detection zone must be crossed before an alarm
is triggered (One Region).
Optional settings: LOW (default), HIGH and One Region.
Note: For EN compliance, the detector should be set to "One Region".
DISARM
ACTIVITY
Define whether or not to set the activity time during Disarm mode.
Optional settings: NOT Active (default), YES – no delay, YES + 5s delay, YES + 15s delay, YES + 30s delay, YES + 1m delay, YES +
2m delay, YES + 5m delay, YES + 10m delay, YES + 20m delay and YES+ 60m delay.
OUTDOOR
ANTI-M
Enable or disable the outdoor anti-masking feature.
Optional settings: Disabled (default) and Enabled.
ALARM
Hours
Define whether motion alarms are always enabled or only when dark (at night).
Optional settings: Day and Night (default) and Night only.
2.5. Local Diagnostic Test
A. Set the detector in local diagnostic mode, as follows:
Open the detector’s bottom cover (see "Figure 4 – Battery Insertion" on the previous page, steps 1 - 3) and then press and release the tamper
switch (see "Figure 5. TOWER 20 AM PG2 " on the next page). The LED will flash for 60 seconds and then the detector will enter into 15 minutes'
local diagnostic mode.
Note: Note: The detector automatically enters into 15 minutes' local diagnostic mode after battery installation or Tamper switch recovery.
B. Adjust the detector in the horizontal plane to cover the required protected area.
C. Walk into the detectors’ field of view. Adjust the vertical plane to receive the maximum number of detections when crossing the entire 90°pattern.
Verify that the LED blinks each time your motion is detected, as you cross one Quad PIR. Then verify that the LED lights steadily for 2 seconds as
you cross the next adjacent Quad PIR. After alarm indication, the LED blinks three times and provides the received signal strength indication (see
Table 2).
Table 2 – Received Signal Strength Indication
LED response Reception
Green LED links Strong
Orange LED blinks Good
Red LED blinks Poor
No blinks No communication
D-304046 TOWER-20 PG2 Installation Instructions 4

Important: Reliable reception must be assured. Therefore, "poor" signal strength is not acceptable. If you receive a "poor" signal from the detector, re-
locate it and re-test until a "Good" or "Strong" signal strength is received.
Note: For detailed Diagnostics Test instructions refer to the control panel Installer's Guide
The LED blinking, described above, is operative only in Local diagnostic mode. Upon each full detection (LED lights steadily for 2 seconds), the control
panel receives the alarm. If required, perform the detector's horizontal / vertical adjustments (see section 2.1 and Figure 3).
Important: Instruct the user to perform a walk test at least once a week, to verify proper operation of the detector.
D. Place a piece of cardboard on the detector’s front side to deliberately mask the optical window. Verify that after 2 minutes, the yellow LED lights
continuously (see Table 3 below) and the alarm control panel receives the masking alarm.
E. Remove the masking from the detector’s front side. Verify that the LED turns off
Table 3 - LED operation
LED Indications Event
Red LED blinks Stabilization (warm-up 60 sec)
Red LED ON 0.2 sec. Tamper open / close
Red LED blinks twice One quad PIR detection in diagnostic mode
Red LED on 2 sec. Intruder alarm
Yellow LED on AM detection – diagnostic mode
Yellow LED blinks slowly (0.2 sec. ON, 30 sec. OFF) AM detection – Normal mode
Note: After detection, the detector disables itself to save battery power. It reverts to the ready state if there is no subsequent detection throughout the
following 2-minute period.
Figure 5. TOWER 20 AM PG2
Callout Description
ALED
BEnroll button
CTamper switch
3. COMPLIANCE WITH STANDARDS
Europe: EN 300220, EN 301489, EN 62368-1, EN 60950-22, EN 50130-4, EN 50130-5, EN 50131-2-2, EN 50131-5-3, EN 50131-6
Type C.
Hereby, Visonic Ltd. declares that the radio equipment type TOWER-20 PG2 is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address: http://www.visonic.com/download-center.
Certified by Norwegian accredited certification body Applica Test & Certification AS in accordance with EN 50131-2-2, EN 50131-5-3,
EN 50131-6, EN 50130-4, and EN 50130-5.
EN 50131-1 Security Grade: According to EN 50131-1 this equipment can be applied in installed systems up to and including Security
Grade 2.
EN 50131-1 Environmental Class: Class IV, IP-55
UK: This product is suitable for use in systems installed to conform to PD6662:2010 at Grade 2 and environmental class 4. DD243 and
BS8243
USA: FCC-CFR 47 Part 15,
Canada: IC-RSS 210
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in residential installations. This equipment generates uses and can radiate
radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio and television
reception.
However, there is no guarantee that interference will not occur in a particular installation. If this device does cause such interference, which can be
verified by turning the device off and on, the user is encouraged to eliminate the interference by one or more of the following measures:
– Re-orient or re-locate the receiving antenna.
– Increase the distance between the device and the receiver.
D-304046 TOWER-20 PG2 Installation Instructions 5

– Connect the device to an outlet on a circuit different from the one that supplies power to the receiver.
– Consult the dealer or an experienced radio/TV technician.
FCC Compliance Statement
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in residential installations. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio and television reception.
However, there is no guarantee that interference will not occur in a particular installation. If this device does cause such interference, which can be
verified by turning the device off and on, the user is encouraged to eliminate the interference by one or more of the following measures:
lRe-orient or re-locate the receiving antenna.
lIncrease the distance between the device and the receiver.
lConnect the device to an outlet on a circuit different from the one that supplies power to the receiver.
lConsult the dealer or an experienced radio/TV technician.
Warning! Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to
operate the equipment.
This device complies with FCC Rules Part 15 and with Industry Canada licence- exempt RSS standard(s). Operation is subject to two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference that may be received or that may cause undesired
operation.
Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisee aux
deux conditions suivantes :(1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioelectrique
subi, meme si le brouillage est susceptible d'en compromettre le fonctionnement.
W.E.E.E. Product Recycling Declaration
For information regarding the recycling of this product you must contact the company from which you orignially purchased it. If you are discarding this product and not returning it for repair then
you must ensure that it is returned as identified by your supplier. This product is not to be thrown away with everyday waste.
Directive 2002/96/EC Waste Electrical and Electronic Equipment.
4. APPENDIX: SPECIFICATIONS
OPTICAL
Black Mirror Max. Coverage Up to 12 m (40 ft) / 90°
Detector Technology 8 independent quad PIR detectors operating in true Quad configuration
Figure 6. Coverage Pattern
A. Top view
B. Side view of each detector
Pet Immunity Up to 18 Kg (40 lb)
ELECTRICAL
Input Power Two 3V CR123A Lithium batteries
Caution! Risk of explosion if battery is replaced by an incorrect type. Dispose of used battery according
to the manufacturer's instructions.
Battery Life (for typical use) 3 years
Low Battery Threshold 4.0 V
Operation voltage 4 V to 6.6 V
Current consumption 25 uA to150 mA
WIRELESS
Frequency Band (MHz) Europe and rest of world: 433-434, 868-869 USA:912-919
Maximum Tx Power 10 dBm @ 433 MHz, 14 dBm @ 868 Mhz
Communication Protocol PowerG
Tamper Alert Reported when a tamper event occurs and in any subsequent message, until the tamper switch is
restored
MOUNTING
D-304046 TOWER-20 PG2 Installation Instructions 6

Mounting Type Wall mounting
Mounting Height 1.5 – 3.0 m (5 – 10 ft).
Horizontal Adjustment -45° to +45°, in 5° steps
Vertical Adjustment 0° to -10°, in 2.5° steps
ENVIRONMENTAL
Operating Temperatures -35°C to 60°C (-31°F to 140°F)
Storage Temperatures -35°C to 60°C (-31°F to 140°F)
Humidity 95% max.
White Light Immunity Above 25000 lux
PHYSICAL
Size (H x L x W) 157 x 147 x 124 mm (6-3/16 x 5-13/16 x 4-7/8”)
Weight (with battery) 600 g (21 oz).
Color White or gray
PATENTS U.S. Patents 7250605 l6818881 l5693943 (other patents pending)
WARRANTY
Visonic Limited (the “Manufacturer") warrants this product only (the "Product") to the original purchaser only (the “Purchaser”) against defective
workmanship and materials under normal use of the Product for a period of twelve (12) months from the date of shipment by the Manufacturer.
This Warranty is absolutely conditional upon the Product having been properly installed, maintained and operated under conditions of normal use in
accordance with the Manufacturers recommended installation and operation instructions. Products which have become defective for any other reason,
according to the Manufacturers discretion, such as improper installation, failure to follow recommended installation and operational instructions, neglect,
willful damage, misuse or vandalism, accidental damage, alteration or tampering, or repair by anyone other than the manufacturer, are not covered by
this Warranty.
There is absolutely no warranty on software, and all software products are sold as a user license under the terms of the software license agreement
included with such Product."
The Manufacturer does not represent that this Product may not be compromised and/or circumvented or that the Product will prevent any death and/or
personal injury and/or damage to property resulting from burglary, robbery, fire or otherwise, or that the Product will in all cases provide adequate
warning or protection. The Product, properly installed and maintained, only reduces the risk of such events without warning and it is not a guarantee or
insurance that such events will not occur.
Conditions to Void Warranty: This warranty applies only to defects in parts and workmanship relating to normal use of the Products. It does not
cover:
* damage incurred in shipping or handling;
* damage caused by disaster such as fire, flood, wind, earthquake or lightning;
* damage due to causes beyond the control of the Seller such as excessive voltage, mechanical shock or water damage;
* damage caused by unauthorized attachment, alterations, modifications or foreign objects being used with or in conjunction with the Products;
* damage caused by peripherals (unless such peripherals were supplied by the Seller;
* defects caused by failure to provide a suitable installation environment for the products;
* damage caused by use of the Products for purposes other than those for which they were designed;
* damage from improper maintenance;
* damage arising out of any other abuse, mishandling or improper application of the Products.
Items Not Covered by Warranty: In addition to the items which void the Warranty, the following items shall not be covered by Warranty: (i) freight cost
to the repair centre; (ii) customs fees, taxes, or VAT that may be due; (iii) Products which are not identified with the Seller's product label and lot number
or serial number; (iv) Products disassembled or repaired in such a manner as to adversely affect performance or prevent adequate inspection or testing
to verify any warranty claim. Access cards or tags returned for replacement under warranty will be credited or replaced at the Seller's option.
THIS WARRANTY IS EXCLUSIVE AND EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, OBLIGATIONS OR LIABILITIES, WHETHER
WRITTEN, ORAL, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE, OR OTHERWISE. IN NO CASE SHALL THE MANUFACTURER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR
INCIDENTAL DAMAGES FOR BREACH OF THIS WARRANTY OR ANY OTHER WARRANTIES WHATSOEVER, AS AFORESAID.
THE MANUFACTURER SHALL IN NO EVENT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, CONSEQUENTIAL OR PUNITIVE
DAMAGES OR FOR LOSS, DAMAGE, OR EXPENSE, INCLUDING LOSS OF USE, PROFITS, REVENUE, OR GOODWILL, DIRECTLY OR
INDIRECTLY ARISING FROM PURCHASER’S USE OR INABILITY TO USE THE PRODUCT, OR FOR LOSS OR DESTRUCTION OF OTHER
PROPERTY OR FROM ANY OTHER CAUSE, EVEN IF MANUFACTURER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
THE MANUFACTURER SHALL HAVE NO LIABILITY FOR ANY DEATH, PERSONAL AND/OR BODILY INJURY AND/OR DAMAGE TO
PROPERTY OR OTHER LOSS WHETHER DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL OR OTHERWISE, BASED ON A CLAIM THAT
THE PRODUCT FAILED TO FUNCTION. HOWEVER, IF THE MANUFACTURER IS HELD LIABLE, WHETHER DIRECTLY OR INDIRECTLY,
FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY, THE MANUFACTURER'S MAXIMUM LIABILITY (IF ANY) SHALL
NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT INVOLVED, WHICH SHALL BE FIXED AS LIQUIDATED DAMAGES
AND NOT AS A PENALTY, AND SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST THE MANUFACTURER. SOME
D-304046 TOWER-20 PG2 Installation Instructions 7

JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THESE
LIMITATIONS MAY NOT APPLY UNDER CERTAIN CIRCUMSTANCES.
When accepting the delivery of the Product, the Purchaser agrees to the said conditions of sale and warranty and he recognizes having been informed
of.
The Manufacturer shall be under no liability whatsoever arising out of the corruption and/or malfunctioning of any telecommunication or electronic
equipment or any programs.
The Manufacturers obligations under this Warranty are limited solely to repair and/or replace at the Manufacturer’s discretion any Product or part
thereof that may prove defective. Any repair and/or replacement shall not extend the original Warranty period. The Manufacturer shall not be
responsible for dismantling and/or reinstallation costs. To exercise this Warranty the Product must be returned to the Manufacturer freight pre-paid and
insured. All freight and insurance costs are the responsibility of the Purchaser and are not included in this Warranty.
For sales in Israel only:
The Purchaser shall comply with the provisions of the Israeli Consumer Protection Law – 1981("Consumer Protection Law") related regulations,
including the Israeli Consumer Protection Regulations (Warranty Sticker), 5772-2012) ("Regulations"), including, without limitation (i) providing its
customers with at least the minimum warranty required by the Consumer Protection Law, and (ii) ensuring that a warranty certificate and a warranty
sticker (as defined in the Regulations) ("Warranty Sticker") shall be attached to any sold Products and the date of the sale of the Product to the
consumer or the end-user shall be added in a readable manner on the Warranty Sticker.
In no event shall the Purchser’s compliance with the Consumer Protection Law and Regulations expand any of the Manufacturer's warranty obligations
under this warranty, and the Purchaser shall be responsible for any warranty that it provides with respect to the Products which exceeds or is different
from this warranty.
This warranty shall not be modified, varied or extended, and the Manufacturer does not authorize any person to act on its behalf in the modification,
variation or extension of this warranty. This warranty shall apply to the Product only. All products, accessories or attachments of others used in
conjunction with the Product, including batteries, shall be covered solely by their own warranty, if any. The Manufacturer shall not be liable for any
damage or loss whatsoever, whether directly, indirectly, incidentally, consequentially or otherwise, caused by the malfunction of the Product due to
products, accessories, or attachments of others, including batteries, used in conjunction with the Products. This Warranty is exclusive to the original
Purchaser and is not assignable.
This Warranty is in addition to and does not affect your legal rights. Any provision in this warranty which is contrary to the Law in the state or country were
the Product is supplied shall not apply.
Governing Law: This disclaimer of warranties and limited warranty are governed by the domestic laws of Israel.
Warning
The user must follow the Manufacturer’s installation and operational instructions including testing the Product and its whole system at least once a week
and to take all necessary precautions for his/her safety and the protection of his/her property.
* In case of a conflict, contradiction or interpretation between the English version of the warranty and other versions, the English version shall prevail.
Email: info@visonic.com
Internet: www.visonic.com
© VISONIC LTD. 2021TOWER-20 PG2D-304046 (Rev. 611/21)
D-304046 TOWER-20 PG2 Installation Instructions 8
Table of contents
Other Tyco Security Sensor manuals

Tyco
Tyco MX-862 User manual

Tyco
Tyco Visonic SD-304C PG2 User manual

Tyco
Tyco DSC PowerSeries PC1616 Manual

Tyco
Tyco FC410DIM User manual

Tyco
Tyco BLAZEMASTER CPVC User manual

Tyco
Tyco SD-304C PG2 User manual

Tyco
Tyco FV300 SERIES User manual

Tyco
Tyco PowerG PG9936H User manual

Tyco
Tyco Visonic PowerG NEXT CAM PG2 User manual

Tyco
Tyco Visonic TOWER-30AM PG2 User manual
Popular Security Sensor manuals by other brands

Wenglor
Wenglor I08G003 operating instructions

Hyundai
Hyundai WS SENZOR 2061 user manual

Honeywell Home
Honeywell Home PROSiX Series Installation and setup guide

Surface Concept
Surface Concept Delayline DLD 8080 manual

Det-Tronics
Det-Tronics X9800 Addendum

JOB
JOB detectomat HDv 300X TS Operation and installation manual