Tyco Visonic TOWER-30AMPG2 User manual

D-303372 TOWER-30AM PG2 / TOWER-30AM K9-90 PG2 Installation Instructions 1
1. INTRODUCTION
The TOWER-30AM PG2 and TOWER-30AM K9-90 PG2 (pet-immune) are 2-way, microprocessor-controlled,
wireless digital mirror PIR detectors which include the following features:
lFor use with all PowerMaster® control panels (version 13 and higher).
lAdaptive Active Infra-Red Anti-Masking technology providing the most advanced reliable protection against
intentional masking attempts (patent pending)
lIncludes a fully supervised PowerG transceiver.
lIncorporates patent pending black mirrors for extremely high white light immunity.
lAdvanced elliptical / parabolic mirror technology (patented)
lV-slot® optic technology (patented) for improved robustness, anti-vandalism and for very high reliability.
lCreep zone protection
lTOWER-30AM K9-90 PG2 can distinguish between human beings and pets weighing up to 40 kg (90 lb).
lThe advanced True Motion Recognition™ algorithm (patented) allows distinguishing between the true motion of
an intruder and any other disturbances which may cause false alarms.
lBuilt-in link quality indicators; no need for the installer to physically approach the control panel thus making
installation faster and easier.
lNo vertical adjustment is needed.
lMotion event counter determines whether 1 or 2 consecutive motion events will trigger an alarm.
lAutomatic termination of walk-test after 15 minutes.
lMicroprocessor-controlled temperature compensation.
lSealed chamber protects the optical system.
lFront and back tamper protection.
lSelf-test
Notes:
1. The pet immunity and creep zone protection were not evaluated by UL.
2. For CE installations, the pet immunity was not evaluated by DNV.
3. The pet immunity feature is not evaluated and certified by Applica Test & Certification AS.
A. Screw cover
B. LED
C. PIR optical window
Figure 1. General View
2. INSTALLATION
2.1. General Guidance (see Fig. 2)
1. Keep away from heat sources.
2. Do not expose to air drafts.
3. Do not install outdoors.
4. Avoid direct sunshine.
5. Keep wiring away from power cables.
6. Do not install behind partitions.
7. Mount on solid stable surface.
lInstalled in accordance with NEC, NFPA 70.
lInstalled in accordance with UL 681, Standard for Installations and
Classifications of burglar and Holdup Alarm Systems.
lInstalled in accordance with C22.1, Canadian Electrical Code, Part
I, Safety Standard for Electrical Installations
Figure 2. General Guidelines
Important! The detector is immune to 40 kg (90 lb) animals moving on the floor or climbing on furniture as long as the activity takes
place below 1 m (3 ft). Above the 1 m (3 ft) height limit, the detector is immune to 9 kg (20 lb) pets, but the pet immunity will
decrease as the pet gets closer to the detector. It is therefore recommended to select a mounting location that minimizes potential
close proximity of animals.
Installation Instructions
TOWER-30AM PG2 / TOWER-30AM K9-90 PG2
Wireless PowerG High-security Mirror Detector with Anti-
masking

Warning! To comply with FCC and IC RF exposure compliance requirements, the PIR detector should be located at a distance of at least 20 cm
from all persons during normal operation. The antennas used for this product must not be co- located or operated in conjunction with any other
antenna or transmitter.
2.2. Mounting
Notes:
1. Mount the detector so that its orientation is perpendicular to the expected intrusion path.
2. For installations of detector at 2m high, Dead zone is 2ft at 0m high and 0.5ft at 1.5m high.
1. On the indicated location, lift the screw cover upward using your
thumb.
2. Release the screw and open the cover in the direction shown by the
arrow.
3. Insert a screwdriver into the slot and then push inward to separate the base from the cover.
Note: For the desired detector's range and height, use mounting holes
or , as specified in the table.
a – upper surface (without downward tilt)
b – lower surface (with downward tilt)
4. Set the desired detector range.
A. Mounting height
B. Coverage range
C. Break-away base segment (shaded)
D-303372 TOWER-30AM PG2 / TOWER-30AM K9-90 PG2 Installation Instructions 2

5. Insert battery while observing polarity.
D. Enroll button (use a screwdriver to press the recessed button)
E. Battery
F. Tamper switch
Caution! THE BACK TAMPER SWITCH WILL NOT PROTECT THE UNIT UNLESS THE BREAK-AWAY BASE SEGMENT IS SECURED TO THE
WALL WITH AT LEAST ONE SCREW.
Caution! RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERY ACCORDING TO
MANUFACTURER'S INSTRUCTIONS.
Note: Back Tamper must be enabled for UL installations.
Figure 3. Mounting
2.3. Enrollment
Refer to the PowerMaster panel's Installer Guide and follow the procedure under the "02:ZONES/DEVICES" option of the Installer Menu. A general
description of the procedure is provided in the following flow chart.
Step 1 Step 2 Step 3 Step 4 Step 5 Step 6
Enter the Installer menu
and select
"02:ZONES/DEVICES"
Select "ADD NEW
DEVICE" Option.
See Note [1]
Enroll the device or
Enter the device ID
Select the desired Zone Number Configure Location,
Zone Type &
Chime Parameters
Configur
e the
Detector
02.ZONES/DEVICESðADD NEW DEVICES
6
MODIFY DEVICES
ðENROLL NOW or
ENTR ID:XXX-XXXX
ðZ14:Motion Sens
ID No. 123-XXXX
ðZ14.LOCATION
Z14.ZONE TYPE
Z14.SET CHIME
ð
means scroll
ww
and select OK.
Z14.DEV SETTINGSSee note
[2]
Notes:
1. If the detector is already enrolled you can configure the detector parameters via the “Modify Devices” option – see Step 2.
2. Select the "Device Settings" option and refer to "Configuring the Detector Parameters" below to configure the detector parameters.
2.4. Configuring the Detector Parameters
Enter the DEVICE SETTINGS menu and follow the configuration instructions for the TOWER- 30AM PG2 PIR detector as described in the following
table.
Option Configuration Instructions
Alarm LED Define whether or not the alarm LED indication will be activated.
Optional settings: LED ON (default) and LED OFF.
Event Counter Define whether an alarm will be activated upon continued motion (low sensitivity) or upon a single alarm event (high sensitivity).
Optional settings: LOW sensitive (default) and HIGH sensitive.
DISARM
Activity
Define whether or not to set the activity time during disarm.
Optional settings: NOT Active (default), YES – no delay, YES + 5s delay, YES + 15s delay, YES + 30s delay, YES + 1m delay, YES +
2m delay, YES + 5m delay, YES + 10m delay, YES + 20m delay and YES + 60m delay.
ANTIMASKING
AM
Define the activity and the sensitivity level of the anti-masking.
Optional settings: LOW sensitive (default), HIGH sensitive and disabled.
3. LOCAL DIAGNOSTICS TEST
Note: Run a diagnostic test at least once a year to ensure that the detector is working correctly.
A. Separate the base from the cover (see Fig. 3).
B. Put back the cover to return the tamper switch to its normal (undisturbed) position, and then secure the front cover to the base with the case
closure screw.
C. The TOWER-30AM PG2 will enter a 2 min. stability period. During this time the red LED blinks.
D-303372 TOWER-30AM PG2 / TOWER-30AM K9-90 PG2 Installation Instructions 3

D. Walk-test the coverage area - see Figure 4. Walk across the far end of coverage pattern in both directions; the red LED lights each time your
motion is detected followed by 3 LED blinks.
The following table indicates the received signal strength indication.
LED response Reception
Green LED blinks Strong
Orange LED blinks Good
Red LED blinks Poor
No blinks No communication
Important! Reliable reception must be assured. Therefore, "poor" signal strength is not acceptable. If you receive a "poor" signal from the detector, re-
locate it and re-test until a "good" or "strong" signal strength is received (in regions requiring UL-compliant installation, only “strong” signal strength is
permitted).
1. For detailed Diagnostics Test instructions refer to the control panel Installer Guide.
2. For UL/CUL installations, the test result must be “Strong”.
4. EVENT INDICATIONS
LED Indications Event
Red LED blinks Stabilization (warm-up 120 sec)
Red LED ON 0.2 sec. Tamper open / close
Red on 2 sec. Intruder alarm
Yellow LED on AM detection – diagnostic mode
Yellow LED blinks slowly (0.2 sec. ON, 30 sec. OFF) AM detection – Normal mode
Yellow and red LED blink simultaneously (0.2 sec. ON [both], 0.2 sec. OFF) Self-test failure – Diagnostic mode
Yellow and red LED blink simultaneously slowly (0.2 sec. ON [both], 30 sec. OFF) Self-test failure – Normal mode
5. SPECIAL COMMENTS
Even the most sophisticated detectors can sometimes be defeated or may fail to warn due to: DC power failure / improper connection, malicious
masking of the lens, tampering with the optical system, decreased sensitivity in ambient temperatures close to that of the human body and unexpected
failure of a component part.
The above list includes the most common reasons for failure to detect intrusion, but is by no means comprehensive. It is therefore recommended that
the detector and the entire alarm system be checked weekly, to ensure proper performance.
An alarm system should not be regarded as a substitute for insurance. Home and property owners or renters should be prudent enough to continue
insuring their lives and property, even though they are protected by an alarm system.
6. COMPLIANCE WITH STANDARDS
Compliance with Standards Europe: EN 50131-1, EN 300220, EN 301489, EN 62368-1, EN 50130-4, EN 50130-5,
EN 50131-2-2 Grade 2 Class II, EN50131-6
Hereby, Visonic Ltd. declares that the radio equipment type Tower-30 AM PG2/Tower-30 AM K9-90 PG2 is in
compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address:
http://www.visonic.com/download-center.
Certified by Norwegian accredited certification body Applica Test & Certification AS in accordance with EN
50131-2-2, EN 50131-6, EN 50131-5-3, EN 50130-4, and EN 50130-5.
Applica T&C has certified only the 868 MHz variant of this product.
UK: This product is suitable for use in systems installed to conform to PD6662 in accordance with EN 50131-2-2
security Grade 2 and environmental Class 2. BS8243
USA: CFR 47 Part 15 (FCC)
Canada: RSS 210
EN 50131-1 Security Grade According to EN 50131-1: this equipment can be applied in installed systems up to and including Security Grade
2.
EN 50131-1 Environmental Class Class II
Visonic Ltd.
M/N: RFD
FCC ID: WP3RFD
IC: 1467-RFD
FCC Compliance Statement
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in residential installations. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio and television reception.
D-303372 TOWER-30AM PG2 / TOWER-30AM K9-90 PG2 Installation Instructions 4

However, there is no guarantee that interference will not occur in a particular installation. If this device does cause such interference, which can be
verified by turning the device off and on, the user is encouraged to eliminate the interference by one or more of the following measures:
lRe-orient or re-locate the receiving antenna.
lIncrease the distance between the device and the receiver.
lConnect the device to an outlet on a circuit different from the one that supplies power to the receiver.
lConsult the dealer or an experienced radio/TV technician.
Warning! Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to
operate the equipment.
This device complies with FCC Rules Part 15 and with Industry Canada license-exempt RSS standard(s). Operation is subject to two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference that may be received or that may cause undesired
operation.
Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisee aux
deux conditions suivantes :(1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioelectrique
subi, meme si le brouillage est susceptible d'en compromettre le fonctionnement.
W.E.E.E. Product Recycling Declaration
For information regarding the recycling of this product you must contact the company from which you orignially purchased it. If you are discarding this product and not returning it for repair then
you must ensure that it is returned as identified by your supplier. This product is not to be thrown away with everyday waste.
Directive 2012/19/EC Waste Electrical and Electronic Equipment.
7. APPENDIX: SPECIFICATIONS
GENERAL
Detector Type Dual element low-noise pyroelectric sensor
Mirror Data No. of Beam Elements:
18x3=54 far parabolic mirror segments
Note: Window material is High Density Polyethylene (HDPE). The window is part of the Enclosure Cover (Item 1).
Max. Coverage 15 m (49 ft) / 90°
A. Horizontal view
B. Vertical view
Figure 4. Coverage Pattern & Walk-test
Pet Immunity (only) Up to 40 kg (90 lb)
ELECTRICAL
Power Supply Type C
Internal Battery 3V Lithium battery, type CR-123A or equivalent (optionally can be used type CR17450)
Notes:
1. Use only the above battery type.
2. For UL installations use Gold Peak (GP) CR123A only.
Nominal Battery
Capacity
1450 mA/h ( 2400mA/h for optional CR17450)
Low Battery
Threshold
2.45 V
Battery Life (for
typical use)
6.5 years
FUNCTIONAL
True Motion Event
Verification
2 remote selections - 1 (OFF) or 2 (ON) motion events
Alarm Period 2 seconds
D-303372 TOWER-30AM PG2 / TOWER-30AM K9-90 PG2 Installation Instructions 5

WIRELESS
Frequency Band
(MHz)
Europe and rest of world: 433-434, 868-869 USA:912-919
Max Tx power 10 dBm @ 433 MHz, 14 dBm @ 868MHz
Communication
Protocol
PowerG
Supervision Signaling at 4-min. intervals
Tamper Alert Reported when a tamper event occurs and in any subsequent message, until the tamper switch is restored
MOUNTING
Height 1.8 – 3.0 m (6 - 10 ft).
Installation Options Surface or corner
ACCESSORIES BR-1: Surface mounted swivel bracket, adjustable 30° down and 45° left/45° right.
BR-2: BR-1 with a corner adapter
BR-3: BR-1 with a ceiling adapter
Notes:
1. UL did not evaluate the product with the use of the BR brackets.
2. The mounting bracket was not tested and not certified according to Belgium TO14A requirements.
ENVIRONMENTAL
RFI Protection >20 V/m up to 2000 MHz, excluding inband frequencies
Operating
Temperatures
-10°C to 50°C (14°F to 122°F) indoor
Note: UL tested 0°C to 49°C
Storage Temperatures -20°C to 60°C (-4°F to 140°F)
Humidity Average relative humidity of up to approximately 75% non-condensing. For 30 days per year the relative humidity may
vary between 85 % and 95 % non-condensing
Note: For UL installations, relative humidity is 85%.
PHYSICAL
Size (H x W x D) 115 x 60 x 48 mm (4-1/2 x 2-5/16 x 1-15/16”)
Weight (with battery) 90 g (3 oz).
Color White
PATENTS U.S. Patents 5,693,943 l6,211,522 lD445,709 (another patent pending)
WARRANTY
Visonic Limited (the “Manufacturer") warrants this product only (the "Product") to the original purchaser only (the
“Purchaser”) against defective workmanship and materials under normal use of the Product for a period of twelve
(12) months from the date of shipment by the Manufacturer.
ThisWarrantyis absolutelyconditionalupon the Product having been properly installed, maintained and operated
under conditions of normal use in accordance with the Manufacturers recommended installation and operation
instructions. Products which have become defective for any other reason, according to the Manufacturers
discretion, such as improper installation, failure to follow recommended installation and operational instructions,
neglect, willful damage, misuse or vandalism, accidental damage, alteration or tampering, or repair by anyone
otherthan the manufacturer, are not covered by thisWarranty.
The Manufacturer does not represent that this Product may not be compromised and/or circumvented or that the
Product willprevent any death and/or personalinjury and/ordamage to property resulting from burglary, robbery,
fire orotherwise, or that the Product will in allcases provide adequate warning or protection.The Product, properly
installed and maintained, onlyreducesthe riskof such events without warning and it isnot a guarantee or insurance
that such events will not occur.
THIS WARRANTY IS EXCLUSIVE AND EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, OBLIGATIONS
OR LIABILITIES, WHETHER WRITTEN, ORAL, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, OR OTHERWISE. IN NO CASE SHALL
THE MANUFACTURER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES
FOR BREACH OF THIS WARRANTY OR ANY OTHER WARRANTIES WHATSOEVER, AS AFORESAID.
THE MANU FACTURER SHALL I N NO EVENT BE LI ABLE FOR ANY SPECIAL, IND IRECT, IN CIDENTA L,
CONSEQUEN TIAL OR PUNITIVE DAMAGES O R FOR LOSS, DAMAGE, OR EXPENSE, INCLU DING LOS S
OF USE, PR OFI TS, RE VEN U E, O R G O OD W IL L, D I REC TL Y O R IN D IR ECT L Y A RI S IN G F R OM
PURCHASER’S USE OR INABILITY TO USE THE PRODUCT, OR FOR LOSS OR DESTRUCTION OF OTHER
PROPERTY O R FRO M AN Y OTH ER CA USE, E VEN IF MA NUFAC TURER HAS BEEN ADVI SED O F TH E
POSSIBILITY OF SUCH DAMAGE.
THE M ANUF ACTUR ER SHALL HAVE NO LIABI LITY FOR ANY DEAT H, PER SONA L AND/ OR B ODIL Y
IN JU R Y A ND/ OR DA M AG E T O PRO PER TY OR OT H ER L OSS WH ET H ER DI R EC T, I ND I RE C T,
INCIDENTAL, CONSEQUENTIAL OR OTHERWISE, BASED ON A CLAIM THAT THE PRODUCT FAILED T O
FUNCTION.
However, if the Manufacturer is held liable, whether directly or indirectly, for any loss or damage arising under this
limited warranty, THE MANUFACTURER’S MAXIMUM LIABILITY (IF ANY) SHALL NOT IN ANY CASE EXCEED
THE PURCHASE PRICE OF THE PRODUCT, which shall be fixed as liquidated damages and not as a penalty, and
shallbe the complete and exclusive remedy against the Manufacturer.
When accepting the deliveryof the Product, the Purchaser agreesto the said conditions of sale and warrantyand he
recognizeshaving been informed of.
Some jurisdictions do not allow the exclusion or limitation of incidental or consequentialdamages, so these limitations
maynot apply under certain circumstances.
The Manufacturer shall be under no liability whatsoever arising out of the corruption and/or malfunctioning of any
telecommunication or electronic equipment or anyprograms.
The Manufacturers obligations under this Warrantyare limited solely to repairand/or replace at the Manufacturer’s
discretion any Product or part thereof that mayprove defective.Any repair and/or replacement shallnot extend the
original Warranty period. The Manufacturer shall not be responsible for dismantling and/or reinstallation costs. To
exercise this Warranty the Product must be returned to the Manufacturer freight pre-paid and insured. Allfreight and
insurance costsare the responsibility of the Purchaser and are not included in thisWarranty.
Thiswarranty shall not be modified, varied or extended, and the Manufacturer doesnot authorize any person to act
on itsbehalf in the modification, variation or extension of this warranty. Thiswarrantyshall applyto the Product only. All
products, accessories or attachments of others used in conjunction with the Product, including batteries, shall be
covered solelyby their own warranty, if any.The Manufacturer shallnot be liable for any damage or loss whatsoever,
whether directly, indirectly, incidentally, consequentiallyorotherwise, caused bythe malfunction of the Product due to
products, accessories, or attachments of others, including batteries, used in conjunction with the Products. This
Warranty isexclusive to the originalPurchaser and isnot assignable.
ThisWarrantyis in addition to and does not affect your legalrights. Anyprovision in thiswarranty which iscontraryto the
Law in the state or countrywere the Product issupplied shallnot apply.
Warning: The user must follow the Manufacturer’s installation and operational instructions including testing the
Product and its whole system at least once a week and to take all necessary precautions for his/her safety and the
protection of his/her property.
1/08
Email: info@visonic.com
Internet: www.visonic.com
© VISONIC LTD. 2021TOWER-30AM PG2 / TOWER-30AM K9-90 PG2D-303372 (Rev. 802/21)
D-303372 TOWER-30AM PG2 / TOWER-30AM K9-90 PG2 Installation Instructions 6
This manual suits for next models
1
Table of contents
Other Tyco Security Sensor manuals

Tyco
Tyco SD-304C PG2 User manual

Tyco
Tyco 614 Series Manual

Tyco
Tyco Visonic TOWER-20 PG2 User manual

Tyco
Tyco DSC WS8904P User manual

Tyco
Tyco WS4933 Series User manual

Tyco
Tyco TOWER-20AM User manual

Tyco
Tyco Visonic TOWER-30AM PG2 User manual

Tyco
Tyco Visonic SD-304C PG2 User manual

Tyco
Tyco Visonic PowerG NEXT CAM PG2 User manual

Tyco
Tyco PowerG PG9936H User manual
Popular Security Sensor manuals by other brands

jablotron
jablotron JA-80S manual

AJAX Systems
AJAX Systems DoorProtect Plus user manual

Kopp
Kopp Free Control BA 807102013 operating instructions

Waters
Waters 2489 Overview and maintenance guide

RKI Instruments
RKI Instruments 35-3010RK-01 manual

System Sensor
System Sensor CO1224T Frequently asked questions