manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. U-Line
  6. •
  7. Ice Maker
  8. •
  9. U-Line UHCL115IS01A Installation manual

U-Line UHCL115IS01A Installation manual

This manual suits for next models

1

Other U-Line Ice Maker manuals

U-Line UMCR014-SC01A Installation manual

U-Line

U-Line UMCR014-SC01A Installation manual

U-Line UMCR014-SS02A Installation manual

U-Line

U-Line UMCR014-SS02A Installation manual

U-Line UMCR015-SS01A Installation manual

U-Line

U-Line UMCR015-SS01A Installation manual

U-Line CLR1215 Installation manual

U-Line

U-Line CLR1215 Installation manual

U-Line ADA SERIES Installation manual

U-Line

U-Line ADA SERIES Installation manual

U-Line UACP115-SS01A Installation manual

U-Line

U-Line UACP115-SS01A Installation manual

U-Line CO1175 User manual

U-Line

U-Line CO1175 User manual

U-Line 1000 SERIES User manual

U-Line

U-Line 1000 SERIES User manual

U-Line BI-95BTP User manual

U-Line

U-Line BI-95BTP User manual

U-Line Origins SP18 User manual

U-Line

U-Line Origins SP18 User manual

U-Line UMCR014-WC01A Installation manual

U-Line

U-Line UMCR014-WC01A Installation manual

U-Line UOCP115-SS01B Installation manual

U-Line

U-Line UOCP115-SS01B Installation manual

U-Line CLRCO2075 User manual

U-Line

U-Line CLRCO2075 User manual

U-Line 3018CLR SERIES User manual

U-Line

U-Line 3018CLR SERIES User manual

U-Line Marine UMCR015 Installation manual

U-Line

U-Line Marine UMCR015 Installation manual

U-Line Acr115 Installation manual

U-Line

U-Line Acr115 Installation manual

U-Line 3018CLR SERIES User manual

U-Line

U-Line 3018CLR SERIES User manual

U-Line WH95TP User manual

U-Line

U-Line WH95TP User manual

U-Line ICE-MAKER User manual

U-Line

U-Line ICE-MAKER User manual

U-Line UOCR115-SS01A Installation manual

U-Line

U-Line UOCR115-SS01A Installation manual

U-Line ULN-SP18FCS-03A User manual

U-Line

U-Line ULN-SP18FCS-03A User manual

U-Line BI1215 1000 Series User manual

U-Line

U-Line BI1215 1000 Series User manual

U-Line Origins BI-98 User manual

U-Line

U-Line Origins BI-98 User manual

U-Line UACR014-BS01A Installation manual

U-Line

U-Line UACR014-BS01A Installation manual

Popular Ice Maker manuals by other brands

camry CR 8073 user manual

camry

camry CR 8073 user manual

Sub-Zero 315I Planning information

Sub-Zero

Sub-Zero 315I Planning information

Kenmore 2217402A Use & care guide

Kenmore

Kenmore 2217402A Use & care guide

Cornelius WM600 Installation & owner's manual

Cornelius

Cornelius WM600 Installation & owner's manual

GE XPIO43SCSS owner's manual

GE

GE XPIO43SCSS owner's manual

Hoshizaki KMD-901MAH Specifications

Hoshizaki

Hoshizaki KMD-901MAH Specifications

Whynter FIM-450HA instruction manual

Whynter

Whynter FIM-450HA instruction manual

Unold 48945 Instructions for use

Unold

Unold 48945 Instructions for use

Andrew James AJ000522 manual

Andrew James

Andrew James AJ000522 manual

Scotsman CME1356 user guide

Scotsman

Scotsman CME1356 user guide

Scotsman ACM 25 Service manual

Scotsman

Scotsman ACM 25 Service manual

Kärcher IP 120 manual

Kärcher

Kärcher IP 120 manual

Maytag MIM1554WRS - Ice Maker User instructions

Maytag

Maytag MIM1554WRS - Ice Maker User instructions

Igloo ICE102-WHITE user manual

Igloo

Igloo ICE102-WHITE user manual

Hoshizaki KM-630MAH instruction manual

Hoshizaki

Hoshizaki KM-630MAH instruction manual

Princess Yonanas user manual

Princess

Princess Yonanas user manual

Unold 48946 Instructions for use

Unold

Unold 48946 Instructions for use

Electrolux E15IM60GP Factory parts catalog

Electrolux

Electrolux E15IM60GP Factory parts catalog

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

USER GUIDE & SERVICE MANUAL
Model: UHCP115-SS81A
USER GUIDE & SERVICE MANUAL
Table of Contents
Click on any section below to jump directly there
Intro
Safety
Safety and Warning
Disposal And Recycling
Installation
Environmental Requirements
Electrical
Cutout & Product Dimensions
Side by Side Installation
Water Hookup
Drain
Anti-Tip Bracket
General Installation
Grille Installation
Door Swing
Door Adjust
Maintenance
Cleaning
Cleaning Condenser
Extended Non-Use
Operating Instructions
First Use
Control Operation
Ice
Airflow and Product Loading
Service
Troubleshooting
Product Liability
Warranty Claims
Parts
Ordering Replacement Parts
R600a Specifications
System Diagnosis Guide
Compressor Specifications
Troubleshooting Extended
Control Operation - Service
Thermistor
Defrost
Warranty
USER GUIDE
Introduction
WELCOME TO U-LINE
Congratulations on your U-Line purchase! Your product comes from a company with decades of premium modular ice
making, refrigeration, and wine preservation experience. U-Line creates products focused on functionality, style, and
inspired innovations — paying close attention to even the smallest details. Applications include residential, outdoor, ADA
height compliant, marine, and commercial. Product categories include Beverage Centers, Wine Refrigerators, Ice Machines,
Refrigerators, Freezers, and Dispensers. Our advanced refrigeration systems, large and exible capacities, and clean
integrated look are what makes our products Built-In to Stand Out®. Since 2014, U-Line has been part of the Middleby family
of brands. Products are designed, engineered, and assembled in Milwaukee, Wisconsin, USA, and select products are available
worldwide.
U-Line — RIGHT PRODUCT. RIGHT PLACE. RIGHT TEMPERATURE.®
PRODUCT INFORMATION
Looking for additional information on your product? User Guides, Spec Sheets, CAD Drawings, and Product Warranty
information are available digitally on u-line.com.
PROPERTY DAMAGE / INJURY CONCERNS
In the unlikely event property damage or personal injury is suspected related to a U-Line product, please take the following
steps:
1. U-Line Customer Care must be contacted immediately at +1.414.354.0300.
2. Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit has been
altered or repaired in the eld without prior written approval from U-Line, claims will not be eligible.
GENERAL INQUIRIES
U-Line Corporation
8900 N. 55th Street
Milwaukee, Wisconsin 53223 USA
Monday - Friday 8:00 am to 4:30 pm CST
T: +1.414.354.0300
Email: sales@u-line.com
u-line.com
CONNECT WITH US
SERVICE & PARTS ASSISTANCE
Monday - Friday 8:00 am to 4:30 pm CST
T: +1.414.354.0300
Service Email: onlineservice@u-line.com
Parts Email: onlineparts@u-line.com
Designed, engineered and assembled in WI, USA
3
USER GUIDE
Safety and Warning
Safety and Warning
NOTICE
Please read all instructions before installing,
operating, or servicing the appliance.
Use this appliance for its intended purpose only and follow
these general precautions with those listed throughout this
guide:
SAFETY ALERT DEFINITIONS
Throughout this guide are safety items labeled with a
Danger, Warning, or Caution based on the risk type:
Danger means that failure to follow this safety
statement will result in severe personal injury or
death.
Warning means that failure to follow this safety
statement could result in serious personal injury
or death.
Caution means that failure to follow this safety
statement may result in minor or moderate
personal injury, property, or equipment damage.
This unit contains R600a (Isobutane) which is a
ammable hydrocarbon. It is safe for regular
use. Do not use sharp objects to expedite
defrosting. Do not service without consulting the
“R600a specications” section included in the
User Guide. Do not damage the refrigerant
circuit.
Service must be done by factory authorized
service personnel. Any parts shall be replaced
with like components. Failure to comply could
increase the risk of possible ignition due to
incorrect parts or improper service.
CALIFORNIA PROPOSITION 65
This product contains chemicals known to the
state of California to cause cancer and birth
defects or other reproductive harm.
www.P65warnings.CA.gov
This equipment is to be installed with adequate
backow protection to comply with applicable
federal, state and local codes.
DANGER
!
DANGER
!
WARNING
!
CAUTION
!
CAUTION
!
WARNING
!
4
USER GUIDE
Disposal and Recycling
Disposal and Recycling
RISK OF CHILD ENTRAPMENT. Before you throw
away your old refrigerator or freezer, take o
the doors and leave shelves in place so children
may not easily climb inside.
If the unit is being removed from service for disposal,
check and obey all federal, state, and local regulations
regarding the disposal and recycling of refrigeration
appliances, and follow these steps completely:
1. Remove all consumable contents from the unit.
2. Unplug the electrical cord from its socket.
3. Remove the door(s)/drawer(s).
DANGER
!
5
USER GUIDE
Environmental Requirements
Environmental Requirements
This model is intended for indoor/interior applications only
and is not to be used in installations that are open/
exposed to natural elements.
This unit is designed to operate between 50°F (10°C) and
100°F (38°C). Higher ambient temperatures may reduce
the unit’s ability to reach low temperatures and/or reduce
ice production on applicable models.
For best performance, keep the unit out of direct sunlight
and away from heat generating equipment.
In climates where high humidity and dew points are
present, condensation may appear on outside surfaces.
This is considered normal. The condensation will
evaporate when the humidity drops.
CAUTION
!
Damages caused by ambient temperatures of
40°F (4°C) or below are not covered by the
warranty.
6
USER GUIDE
Electrical
Electrical
WARNING
!
SHOCK HAZARD — Electrical Grounding
Required. Never attempt to repair or perform
maintenance on the unit until the electricity has
been disconnected.
Never remove the round grounding prong from
the plug and never use a two-prong grounding
adapter.
Altering, cutting or removing power cord,
removing power plug, or direct wiring can cause
serious injury, fire, loss of property and/or life,
and will void the warranty.
Never use an extension cord to connect power to
the unit.
Always keep your working area dry.
NOTICE
Electrical installation must observe all state and
local codes. This unit requires connection to a
grounded (three-prong), polarized receptacle
that has been placed by a qualified electrician.
The unit requires a grounded and polarized 115 VAC,
60 Hz, 15A power supply (normal household current). An
individual, properly grounded branch circuit or circuit
breaker is recommended. A GFCI (ground fault circuit
interrupter) is usually not required for fixed location
appliances and is not recommended for your unit because
it could be prone to nuisance tripping. However, be sure
to consult your local codes.
See CUTOUT & PRODUCT DIMENSIONS for recommended
receptacle location.
7
USER GUIDE
Cutout & Product Dimensions
4”
(102 mm)
1
½
”
(38 mm)
2
⁄
”
(73 mm)
4”
(102 mm)
Drain
Power Cord
Water Line
7
½
”
(102 mm)
8”
(203 mm)
6 ft (183 cm)
Cutout & Product Dimensions
PREPARE SITE
Your U-Line product has been designed for either free-
standing or built-in installation. When built-in, your unit
does not require additional air space for top, sides, or
rear. However, the front grille must NOT be obstructed,
and clearance is required for an electrical connection in
the rear.
CAUTION
!
Unit can NOT be installed behind a closed
cabinet door.
If you would like to align the face of the unit
with other adjacent cabinet doors, you may need
to alter the wall just behind the drain connection
on the unit to accommodate the drain.
CUTOUT DIMENSIONS
*15” cutout width sufficient if door protrudes beyond
adjacent cabinetry
PRODUCT DIMENSIONS
REAR
1 ΍ȟȭ" (38 mm)
7"
(178 mm)
15 ΍ȟȯ"
(387 mm)
34 ΍ȟȯ"
(870 mm)
to
35 ΍ȟȯ"
(889 mm)
Preferred location
for electrical outlet
is in an adjacent
cabinet.
24"
(610 mm)
ΑȟΞ"
(16 mm)
14 ⁄”
(379 mm)
3 ⁄”
(91 mm)
28”
(711 mm) 34 ⁄” to 35 ⁄”
(867 mm to
892 mm)
1 ⁄”
(48 mm)
11 ⁄”
(291 mm)
15 ½”
(394 mm)
20 ⁄”
(525 mm)
TOP
FRONT
SIDE
12 ⁄”
(306 mm)
22 ¼”
(562 mm)
24 ⁄”
(613 mm)
1“ (25 mm)
8
USER GUIDE
Side-by-Side Installation
Side-by-Side Installation
Two units may be installed side-by-side.
Cutout width for a side-by-side installation is the cutout
dimension of a single unit times two.
No trim kit is required. However, 1/4" (6 mm) of space
needs to be maintained between the units to ensure
unobstructed door swing.
Units must operate from separate, properly grounded
electrical receptacles placed according to each unit’s
electrical specifications requirements.
Side-by-Side Installation with Bracket
1. Slide both units out so screws on top of units are easily
accessible.
2. Remove screws as shown below.
3. Place bracket over holes and attach to unit with two
screws removed in step 2 using a T-25 Torx driver.
Tighten screws fully.
4. Gently push units into position. Be careful not to
entangle the electrical cord or water line, if applicable.
5. Re-check the leveling, from front to back and side to
side. Make any necessary adjustments. The unit’s top
surface should be approximately 1/8" (3 mm) below
the countertop.
9
USER GUIDE
Water Hookup
Water Hookup
PREPARE PLUMBING
The water valve uses a standard 1/4” (6.35 mm)
compression fitting.
U-Line recommends using accessory water hookup kit -
Part # ULAWATERHOOKUP. The kit includes a 10’ (3 m)
braided flexible water supply line and a brass hose
fitting.
WARNING
!
Prior to installation, determine if this product
contains a gravity style drain or factory installed
drain pump. Products without a drain pump may
only use a gravity style drain. Failure to connect
water supply or drain line connections properly
may result in water leakage, personal injury,
and/or property damage. Disconnect power and
turn off water to the unit before attempting to
alter these connections. These connections are
the responsibility of the owner and must be
connected per local plumbing code. If you are
uncertain of how to safely and properly install
this product, contact a licensed plumber.
Water Supply Connection
WARNING
!
Connect to potable water supply only.
CAUTION
!
Review, obey, and understand the local
plumbing codes before you install your unit.
Connect to the cold water supply. The water
pressure should be between 20 and 120 psi (138
and 827 kPa). The water line MUST have a shut-
off valve on the supply line.
CAUTION
!
Do not use any plastic water supply line. The line
is under pressure at all times. Plastic may crack
or rupture with age and cause damage to your
home.
Do not use tape or joint compound when
attaching a braided flexible water supply line
that includes a rubber gasket. The gasket
provides an adequate seal – other materials
could cause blockage of the valve.
Failure to follow recommendations and
instructions may result in damage and/or harm,
flooding or void the product warranty.
CAUTION
!
Turn off water supply and disconnect electrical
supply to unit prior to installation.
Use caution when handling back panel. The
edges could be sharp.
1. Turn off water supply and disconnect electrical supply
to product prior to attempting installation.
2. Remove the grille/access panel in the front and the
back panel.
10