Ubisys C4 User manual

As per 02/2017Page 1/2
Specifications
The control unit C4 is a radio controlled device with 4 universal inputs to
control further smart home components. In the current flush mount version,
it is compatible to standard switch boxes and fully integrates into the rest of
your smart home. It is not only suitable for new buildings, but also for existing
buildings, because retrofitting has, due to use of radio technology, no special
requirements to the electrical installation. For new buildings and renovations,
it helps reducing both planning and cabling costs. The system can gradually
be extended by adding new components. Determine scope and timing at any
time by yourself.
The control unit C4 is an additional option and offers full functionality when
combined with other components of the ubisys smart home product line and
allows for example:
• Freely configurable assignments between control elements and consu-
mers
• Scenes and group controlling
• Can be connected to switches and motion sensors
More information about the features of the ubisys smart home product line
can be found at www.ubisys.de.
Installation
The control unit C4 is designed for installation in flush mounted sockets
according to DIN 49073. For installation behind a switch, power socket or
motion sensor, deep sockets are recommended.
Leads: Dimensions:
For installation of the control unit C4, the included clamps can be used.
During installation, the general risks of household voltage networks have to
be noted!
Basic ZigBee Commissioning
The device joins an open ZigBee network when it is factory new and power
is applied.
Funkvernetzt mit
Stromverbrauchsmessung
Leistungsschalter S2
230 V ~/50 Hz, 2 x 500 VA
2 12 1
Leistungsschalter S1
Funkvernetzt mit
Stromverbrauchsmessung
230 V ~/50 Hz, 3.680 VA
Funkvernetzt mit
Stromverbrauchsmessung
Jalousiesteuerung J1
230 V ~/50 Hz, 500 VA
2121
Funkvernetzt mit
Stromverbrauchsmessung
Universaldimmer D1
230 V ~/50 Hz, 500 VA
2 1
Funkvernetzt
Bedieneinheit C4
AC 230 V ~/50 Hz
2 14 3
Funkvernetzt
Router R0
AC 230 V ~/50 Hz
Router R0
90 - 270 V~, 50/60 Hz
(12 - 400 V=)
Funkvernetzt mit
Stromverbrauchsmessung
Universaldimmer D1
230 V ~/50 Hz, 500 VA
21
2143
2143
Leistungsschalter S1
Funkvernetzt mit
Stromverbrauchsmessung
230 V ~/50 Hz, 3.680 VA
Funkvernetzt mit
Stromverbrauchsmessung
Jalousiesteuerung J1
230 V ~/50 Hz, 500 VA
2121
Funkvernetzt
Bedieneinheit C4
AC 230 V ~/50 Hz
2
Funkvernetzt
Router R0
230 V ~/50 Hz
2
Router R0
2
Funkvernetzt
Bedieneinheit C4
AC 230 V ~/50 Hz
2
Funkvernetzt mit
Stromverbrauchsmessung
Leistungsschalter S2
230 V ~/50 Hz, 2 x 500 VA
2121
90 - 270 V~, 50/60 Hz
(12 - 400 V=)
47 mm
43 mm
43 mm
43 mm
43 mm
12 mm
143 mm
12 mm
143 mm
12 mm
143 mm
12 mm
143 mm
12 mm 47 mm 12 mm47 mm 12 mm47 mm 17 mm
47 mm
43 mm
12 mm
143 mm
12 mm
47 mm
43 mm
12 mm
143 mm
12 mm 47 mm
43 mm
12 mm
143 mm
12 mm47 mm
43 mm
12 mm
143 mm
12 mm
Factory Reset
Power-Cycle Sequencing Factory Reset: It is possible to instigate a factory
reset using a special power-cycle sequence. This is equivalent to selecting
menu item #5, with the advantage that you need no access to the device
itself (only to its power supply).
1. Power the device for at least four seconds.
2. Interrupt the power supply for at least a second.
3. Reapply power for less than two seconds but more than half a second.
Notice that at the end of this cycle, the device is off and should remain off for
at least a second.
4. Repeat the previous step two more times, for a total of three short
power cycles.
5. Apply power to the device and leave it powered on. The device will now
factory reset and reboot.
Factory Reset via Button: To reset the device to its factory fresh settings
(e.g. in order to join it to another network afterwards), press the button in the
larger of the two holes on the front for more than 10 seconds until the LED
starts flashing rapidly.*)
Only use the electrically isolated tool provided with the device to press the
button in the hole.
*) If the device has legacy firmware this feature might not be available. In this
case, keep the button pressed for one second, until the LED flashes three
times and then blinks once every second. Then press the button four times
for less than a second, until the LED flashes five times, followed by a pause,
then flashes five times again, followed by a pause, etc. In this state, keep the
button pressed for more than a second until the LED starts flashing rapidly.
Configuration
The control unit C4 has 4 inputs. Every single input can be configured indivi-
dually and can be used to control smart home components.
For integration into the smart home radio network, the control unit C4 has to
be configured first. Direct access to the control unit C4 is not necessary for
configuration. That means that network configuration can also be done after
successful electrical installation. It is best to hold the 16 digit serial number
of the control unit C4 in the construction plan during installation. This allows
you to allocate the device at a later point.
When connected to power, the control unit C4 automatically logs into the
ZigBee network. After that it can be configured via the electrician’s installati-
on software (ubisys Network Manager) or the ubisys smartphone app.
More information about adding and configuring ubisys smart home compon-
ents can be found in the ubisys Smart Home Installation manual.
Technical Information
Rated voltage 230 V ~, 50 Hz
Own consumption 0.3 W
Radio technology ZigBee 3.0 in 2.4 GHz ISM Band,
IEEE 802.15.4 channels 11-26, 0…5dBm
transmitting power *)
Environment temperature -20°C - +45°C
*) More information about radio technology can be found at www.ubisys.de.
Funkvernetzt mit
Stromverbrauchsmessung
Leistungsschalter S2
230 V ~/50 Hz, 2 x 500 VA
2 12 1
Leistungsschalter S1
Funkvernetzt mit
Stromverbrauchsmessung
230 V ~/50 Hz, 3.680 VA
Funkvernetzt mit
Stromverbrauchsmessung
Jalousiesteuerung J1
230 V ~/50 Hz, 500 VA
2121
Funkvernetzt mit
Stromverbrauchsmessung
Universaldimmer D1
230 V ~/50 Hz, 500 VA
2 1
Funkvernetzt
Bedieneinheit C4
AC 230 V ~/50 Hz
2 14 3
Funkvernetzt
Router R0
AC 230 V ~/50 Hz
Button
LED
Button
LED
Button
LED
Button
LED
Button
LED
Button
LED
Router R0
Button
LED
90 - 270 V~, 50/60 Hz
(12 - 400 V=)
Control unit C4
Radio linked

As per 02/2017Page 2/2
Caution
Subjecting the inputs (white, grey) with voltage without correct connection of L, N will
destroy the device.
Caution
Even unconnected ports (white, grey) can carry threatening voltages.
Hazard notes
Installation should only be performed by a qualified electrician. Wrong wiring from not
following instructions can cause unforeseen behavior, such as fire or destruction of
the device. There is a risk of electric shock. Electrical shock can result in death. Prior
to installation, enable voltage and cover live parts. Opening the unit or other devices
voids the warranty.
Conformity
This device complies with the applicable directives and standards of the EU
match.
Manufacturer
ubisys technologies GmbH
Am Wehrhahn 45
40211 Düsseldorf
Germany
www.ubisys.de
Control unit C4
Radio linked
Other Ubisys Control Unit manuals