UbiTech Custos BVS-ZW Series User manual

BVS-ZWx User Manual
Ubitech Ltd. Ve rs io n: 0 .9 .4
Page: 1
Custos Ball Valve Servo
Technology for Humanity

BVS-ZWx User Manual Date:02-APR-2020
Ubitech Ltd. Ve rs io n: 0 .9 .4
Page: 2
INDEX
1. INTRODUCTIONS
1.1 Custos BVS
1.2 What’s Z-Wave
2. FEATURES & SPECIFICATIONS
2.1 Physical Specifications
2.2 Hardware Specifications
2.3 Software Specifications
3. Z-WAVE SOFTWARE DEFINITIONS
3.1 Z-Wave Plus Info
3.2 Version CC
3.3 Manufacturer Specifications
3.4 Notification CC
3.5 Indicator CC
3.6 Basic CC Mapping of Water Valve
3.7 Association Group Info (AGI)
3.8 Support Command Class in NIF
3.9 Configuration CC
4. WHAT INSIDE IN THE BOX
5. UNDERSTANDING CUSTOS BVS
5.1 Connectors & Interfaces
6. KEY & INDICATORS BEHVIOR
6.1 Touch Sen se Button
6.2 Visual Indicator
6.3 Sound Indicator
7. PHYSICAL INSTALLATION
7.1 Quick Installation instruction
8. WORKING MODE SUPPORT
8.1 Standalone Mode
8.2 Mesh Network
8.3 Water Valve Operation
8.4 Water Leak Alarm
8.5 Temperature Sensor
9. TOUCH SENSE BUTTON KEYLOCK
9.1 Keylock Enable
9.2 Keylock Disable
10. SETUP Z-WAVE NETWORK
10.1 Check Custos BVS Status
10.2 Add Custos BVS Into Z-Wave Network
10.3 Remove Custos BVS From Z-Wave Network
10.4 Factory Default Reset

BVS-ZWx User Manual Date:02-APR-2020
Ubitech Ltd. Ve rs io n: 0 .9 .4
Page: 3
11. WATER VALVE OPERATION
11.1 Forced-calibration Valve Position
11.2 Turn Valve To OPEN
11.3 Turn Valve To CLOSE
11.4 Pause OPEN/CLOSE Operation
11.5 Resume OPEN/CLOSE Operation
12. WATER LEAK ALARM
12.1 Water Leak Detection & Alarm
12.2 Water Leak Alarm Cancellation
13. TEMPERATURE SENSOR REPORT
13.1 Temperature Report
14.
APPENDIX
14.1
Z-Wave Terminology
14.2
System Event Status
14.3
Touch Sensor Button Key Lock
14.4
Operation Mode
14.5
Network Operation & Status
14.6
Water Valve Operation & Status
14.7
Water Leak Alarm Operation & Status

BVS-ZWx User Manual
Ubitech Ltd. Ve rs io n: 0 .9 .4
Page: 4
1 INTRODUCTION
1.1 What’s Z-Wave
Z-Wave is international wireless protocol used for Smart Home. It’s a mash network technology to ensure reliable two-
way communication with each other.
Z-Wave provides interoperability and security from multivendor to make sure Certificated product works within any same
Z-Wave network.
1.2 Custos BVS
Cusots Ball Valve Servo “Custos BVS” is capable for outdoor deployment for control water valve open / close. It also
support auto close valve when water leak is detected by built-in leak sensor. Custos BVS can be operated in any Z-Wave
network with other Z-Wave certified gateways or devices from other manufacturers. All mains operated nodes within the
network will act as repeaters regardless of vendor to increase reliability of the network.

BVS-ZWx User Manual Date:02-APR-2020
Ubitech Ltd. Ve rs io n: 0 .9 .4
Page: 5
2 FEATURES & SPECIFICATIONS
2.1 Physical Specifications
Parameter
Value
Model No.
BVS-ZWU (US) / BVS-ZWE (EU)
Dimensions
14.8 x 9.6 x 13.3mm
Weight
BVS Unit: 603g
Body Color
White
Knob Color
Blue
Waterproof and Dustproof
IP66 level / Outdoor deployment
Usage
For Indoor and Outdoor Water Valve On/Off
Operation Temperature
14~122° F (-10 ~ +50°C)
Relative Humidity
8% ~ 80%
2.2 Hardware Specifications
Parameter
Value
Z-Wave Module
ZGM130S037HGN1
Z-Wave RF Distance
40m (Indoor) / 140m (Outdoor)
Region Frequency
US: 908.4 & 916MHz, FCC CFR47 Part 15.249
EU: 868.42 & 869.85MHz
Motor Torque Power
Adaptive torque output max: 6n.m
Water Leak Sensor
Local Water Leak Sensor Probe
Temperature Sensor
Built-in MCP9700x, Range from -40°C to +125°C / (-40°F to +257°F)
Action Button
Touch Sense Button x 1
LED Indicator
3 colors LED. (Green, Yellow & Red)
Sound Indicator
Buzzer (Max. 85dB)
Power Supply
AC-DC: AC (110V 60Hz / 220V 50Hz); DC (12V / 1A)
Power Consumption
Standby: ~10mA @ 12VDC = 0.12W
Full Operation: Max ~700mA @ 12VDC = 8.4W

BVS-ZWx User Manual Date:02-APR-2020
Ubitech Ltd. Ve rs io n: 0 .9 .4
Page: 6
2.3 Software Specifications
Parameter
Value
Wireless Technology
Z-Wave
Z-Wave Certification Type
Z-Wave Plus v2 Certification
Z-Wave SDK Ver s ion
v7.13.2
Z-Wave Library
Enhanced 232 Slave
Z-Wave Role Type
Always On Slave
Device Type
Binary Switch
Generic Device Type
Switch Binary
Specific Device Type
Valve Open Close
Security Class
Non-Security, S0, S2 Unauthenticated and S2 Authenticated
SmartStart
Support: After powering on, SmartStart is auto activated if it’s out of Z-Wave network when power on
Firmware Update
Support: Firmware upgrade support via RF, “Over The Air (OTA)”
Association
Support.
Factory Default Reset
Support: Device Locally Reset
Power Down Memory
Support: Valve ON/OFF and Leak Alarm support suddenly power cut and restore previous status

BVS-ZWx User Manual Date:02-APR-2020
Ubitech Ltd. Ve rs io n: 0 .9 .4
Page: 7
3 Z-WAVE SOFTWARE DEFINITIONS
3.1 Z-Wave Plus Info
Z-Wave Plus Ver s i on
2
Role Type
5 (ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_ALWAYS_ON)
Node Type
0 (ZWAVEPLUS_INFO_REPORT_NODE_TYPE_ZWAVEPLUS_NODE)
Installer Icon Type
0x1500 (ICON_TYPE_GENERIC_VALVE_OPEN_CLOSE)
User Icon Type
0x1500 (ICON_TYPE_GENERIC_VALVE_OPEN_CLOSE)
3.2 Version CC
Parameter
Value
Z-Wave Protocol Library Type
0x03
Z-Wave Protocol Version
0x07
Z-Wave Protocol Sub Version
0x0B
Firmware 0 Version
0x03
Firmware 0 Sub Version
0x02
Hardware Version
0x03
Number of firmware targets
0x00
3.3 Manufacturer Specifications
Parameter
Value
Manufacturer ID 1
0x02
Manufacturer ID 2
0x70
Product Type ID 1
US=0x01
Product Type ID 2
0x01
Product ID 1
0x00
Product ID 2
0x0A

BVS-ZWx User Manual Date:02-APR-2020
Ubitech Ltd. Ve rs io n: 0 .9 .4
Page: 8
3.4 Notification CC
Notification
Type
Notification Events / State
Description
Heat Alarm
0x04
State idle
0x00
Notification value for the state variable going to idle (V5)
Overheat detected
0x02
No Location Support Event
Underheat detected
0x06
No Location Support Event
Water Alarm
0x05
State idle
0x00
Notification value for the state variable going to idle (V5)
Water leak detected
0x02
No Location Support Event
Water Valve
0x0F
Valve operation status
0x01
Event Parameter 1 byte =
- 0x00 = Valve does not let the water run through
- 0x01 = Valve lets the water run through
3.5 Indicator CC
Parameter
Value
Indicator ID
0x50 = (Node Identify)
Property ID
0x03 = (On/Off Periods)
0x04 = (On/Off Cycles)
0x05 = (On time within an On/Off period)
3.6 Basic CC Mapping of Water Valve
Basic CC
Map to CC
Value
BASIC_SET
BINARY SWITCH SET
0x00 = ON / Water Valve OPEN (Valve lets water run through)
0xFF = OFF / Water Valve CLOSE (Valve doesn’t let water run through)
BASIC_GET
BINARY SWITCH GET
0x00 = ON / Water Valve OPEN (Valve lets water run through)
0xFF = OFF / Water Valve CLOSE (Valve doesn’t let water run through)

BVS-ZWx User Manual Date:02-APR-2020
Ubitech Ltd. Ve rs io n: 0 .9 .4
Page: 9
3.7 Association Group Info (AGI)
Association
Group
Name
Node
Count
Function
1
Lifeline
5
- Device Reset Locally Notification
- Basic Report
- Binary Switch Report
- Indicator Report
- Sensor Multilevel Report – Temperature “Auto report based on Configuration Parameter 0x22 Setting.”
- Heat Alarm Notification Report (0x04)
- 0x00 = State idle
- 0x02 = Overheat – no location support
- 0x06 = Underheat – no location support
- Water Alarm Notification Report (0x05)
- 0x00 = State idle
- 0x02 = Water leak detected – no location support
- Water Valve Notification Report (0x0F)
- 0x01 = Valve operation
l 0x00 = VALVE CLOSED/OFF (Valve does not let the water run through.)
l 0x01 = VALVE OPEN/ON (Valve lets the water run through)
2
Water Valve
3
- Basic Set
- 0x00 = Doesn’t let the water run through (Based on Configuration Parameter 0x12 Setting)
- 0xFF = Let the water run through (Based on Configuration Parameter 0x13 Setting)
3
Water Leak
3
- Basic Set
- 0x00 = IDEL / CANCEL (Based on Configuration Parameter 0x31 Setting)
- 0xFF = TRIGGERED (Based on Configuration Parameter 0x32 Setting)
4
Overheat
3
- Basic Set
- 0x00 = IDEL / CANCEL (Based on Configuration Parameter 0x27 Setting)
- 0xFF = TRIGGERED (Based on Configuration Parameter 0x26 Setting)
5
Underheat
3
- Basic Set
- 0x00 = IDEL / CANCEL (Based on Configuration Parameter 0x2C Setting)
- 0xFF = TRIGGERED (Based on Configuration Parameter 0x2B Setting)

BVS-ZWx User Manual Date:02-APR-2020
Ubitech Ltd. Ve rs io n: 0 .9 .4
Page: 10
3.8 Supported Command Classes In NIF
Command Class
Version
Not added
Non-
secure
added
Security 0 added
Security 2 added
Non-
secure
Secure
Non-
Secure
Secure
ZWAVE P L US_I N F O
2
Support
Support
Support
---
Support
----
ASSOCIATION
3
Support
Support
---
Support
---
Support
ASSOCIATION_GRP_INFO
3
Support
Support
---
Support
---
Support
TRANSPORT_SERVICE
2
Support
Support
Support
---
Support
---
SWITCH_BINARY
2
Support
Support
---
Support
---
Support
INDICATOR
3
Support
Support
---
Support
---
Support
NOTIFICATION
8
Support
Support
---
Support
---
Support
VERSION
3
Support
Support
---
Support
---
Support
MANUFACTURER_SPECIFIC
2
Support
Support
---
Support
---
Support
DEVICE_RESET_LOCALLY
1
Support
Support
---
Support
---
Support
POWERLEVEL
1
Support
Support
---
Support
---
Support
SECURITY
1
Support
Support
Support
---
Support
---
SECURITY_2
1
Support
Support
Support
---
Support
---
SUPERVISION
1
Support
Support
Support
---
Support
---
FIRMWARE_UPDATE_MD
6
Support
Support
---
Support
---
Support
MULTI_CHANNEL_ASSOCIATION
4
Support
Support
---
Support
---
Support
SENSOR_BINARY
2
Support
Support
---
Support
---
Support
SENSOR_MULTILEVEL - Temperature
11
Support
Support
---
Support
---
Support
CONFIGURATION
4
Support
Support
---
Support
---
Support

BVS-ZWx User Manual Date:02-APR-2020
Ubitech Ltd. Ve rs io n: 0 .9 .4
Page: 11
3.9 Configuration CC
Note: No Bulk Support equals to True. It will return an Application Rejected Request Command when receiving Configuration Bulk
Set or Get (if received without Supervision encapsulation). It will reset all its configuration parameters if either manually reset to
factory default or receives a Configuration Default Reset Command. It will NOT modify or reset any configuration parameter when
being included or excluded of a Z-Wave network
Type
Parameter
No.
Name & Info
Size
Value
Default
Hex
Dec
System
0x01
1
Name: Reset Parameter
Info: Resort all parameters to factory default
1 Byte
0x00 = Disable
0x01 = Enable
0x00
Water Valve
0x11
17
Name: Inverse Water Valve Report
Info: Inverse Switch Binary Report value
1 Byte
0x00 = 0x00 = CLOSE, 0xFF = OPEN
0x01 = 0x00 = OPEN, 0xFF = CLOSE
0x01
0x12
18
Name: Association Group 2 Reports 0xFF SET Value
Info: Configure Valve SET Value when receives 0xFF
1 Byte
0x00 = Disable
0x01 = Basic ON (0xFF)
0x02 = Basic OFF (0x00)
0x01
0x13
19
Name: Association Group 2 Reports 0x00 SET Value
Info: Configure Valve SET Value when receives 0x00
1 Byte
0x00 = Disable
0x01 = Basic ON (0xFF)
0x02 = Basic OFF (0x00)
0x02
0x14
20
Name: Forced Valve Calibration
Info: Perform Valve Position Calibration
1 Byte
0x00 = Disable / Ignore
0x01 = Perform Calibration
0x00
Temperature
Sensor
0x21
33
Name: Temperature Report Unit
Info: Configure reporting temperature unit
*By default. US=°F and EU=°F
1 Byte
0x00 = Disable Temperature Report
0x01 = Report with Celsius (°C)
0x02 = Report with Fahrenheit (°F)
0x02
0x22
34
Name: Temperature Threshold Change
Info: Configure Temperature Threshold to auto report
2 Bytes
0x0000~0x00FF = Celsius (°C)
0x0100~0x01FF = Fahrenheit (°F)
0x0001 = 1°C
0x0104 =~4°F
0x23
35
Name: Temperature Sensor Offset
Info: Configure Temperature Sensor Offset
First 4 bits = +/- value; 0 = Positive, 1 = Negative
Second 4 bits = Celsius/Fahrenheit; 0 = °C, 1 = °F
2 Bytes
0x0000~0x00FF = Set +°C value
0x1000~0x10FF = Set -°C value
0x0100~0x01FF = Set +°F value
0x1100~0x11FF = Set -°F value
0x0000 = 0°C;
0x0100
=~32°F
0x24
36
Name: Overheat Trigger Value
Info: Configure Overheat Trigger Report Value
2 Bytes
0x0000~0x00FF = Set °C value
0x0100~0x01FF = Set °F value
0x0040=°C
0x0168=°F

BVS-ZWx User Manual Date:02-APR-2020
Ubitech Ltd. Ve rs io n: 0 .9 .4
Page: 12
*3.9 Configuration CC – Continue
Type
Parameter
No.
Description
Size
Value
Default
Hex
Dec
T
emperature
Sensor
(Cont.)
0x25
37
Name: Overheat Recover Val ue
Info: Configure overheat recover report value
2 Bytes
0x0000~0x00FF = Set °C value
0x0100~0x01FF = Set °F value
0x0030=°C
0x0156=°F
0x26
38
Name: Association Group 4 Overheat Trigger Va lue
Info: Configure overheat trigger SET value
1 Byte
0x00 = Disable
0x01 = Send Basic ON (0xFF)
0x02 = Send Basic OFF (0x00)
0x00
0x27
39
Name: Association Group 4 Overheat Cancellation Valu e
Info: Configure overheat cancellation SET value
1 Byte
0x00 = Disable
0x01 = Send Basic ON (0xFF)
0x02 = Send Basic OFF (0x00)
0x00
0x28
40
Name: Freeze Trigger Value
Info: Configure Freeze Trigger Report Value
2 Bytes
0x0000~0x00FF = Set °C value
0x0100~0x01FF = Set °F value
0x0000 = 0°C
0x0120 = 0°F
0x29
41
Name: Freeze Recover Va l u e
Info: Configure Freeze Recover Report Value
2 Bytes
0x0000~0x00FF = Set °C value
0x0100~0x01FF = Set °F value
0x0004 = 4°C
0x0128 = 40°F
0x2A
42
Name: Freeze Detection Va lv e Con tr ol Forbidden
Info: Enable / Disable valve control when freeze detection
1 Byte
0x00 = Allowed
0x01 = Forbidden
0x00
0x2B
43
Name: Association Group 5 Freeze Trigger
Info: Configure freeze trigger SET value
1 Byte
0x00 = Disable
0x01 = Send Basic ON (0xFF)
0x02 = Send Basic OFF (0x00)
0x00
0x2C
44
Name: Association Group 5 Freeze Cancellation
Info: Configure freeze cancellation SET value
1 Byte
0x00 = Disable
0x01 = Send Basic ON (0xFF)
0x02 = Send Basic OFF (0x00)
0x00
Water Leak
0x31
49
Name: Association Group 3 Water Leak Trigger Value
Info: Configure Water Leak Trigger SET value
1 Byte
0x00 = Disable
0x01 = Send Basic ON (0xFF)
0x02 = Send Basic OFF (0x00)
0x01
0x32
50
Name: Association Group 3 Water Leak Cancellation Value
Info: Configure Water Leak Cancellation value
1 Byte
0x00 = Disable
0x01 = Send Basic ON (0xFF)
0x02 = Send Basic OFF (0x00)
0x00
0x33
51
Name: Water Leak Detection
Info: Enable / Disable Water Leak Detection
1 Byte
0x00 = Disable
0x01 = Enable
0x01

BVS-ZWx User Manual Date:02-APR-2020
Ubitech Ltd. Ve rs io n: 0 .9 .4
Page: 13
*3.9 Configuration CC – Continue
Type
Parameter
No.
Description
Size
Value
Default
Hex
Dec
User
Interface
0x41
65
Name: Buzzer
Info: Disable / Enable Buzzer
1 Byte
0x00 = Disable
0x01 = Enable
0x01
0x42
66
Name: LED Brightness Level
Info: Configure LED brightness level
1 Byte
0x00~0x63
0x50
0x43
67
Name: Touch Keylock
Info: Disable / Enable Touch Keylock function
1 Byte
0x00 = Disable
0x01 = Enable
0x00
Notification
Report
0x51
81
Name: Notification Report
Info: Configure Notification Report (Bitmask)
1 Byte
Bitmask
Bit 0 = Water Valve Report
Bit 1 = Overheat Report
Bit 2 = Freeze Report
Bit 3 = Water leak
0x0D

BVS-ZWx User Manual Date:02-APR-2020
Ubitech Ltd. Ve rs io n: 0 .9 .4
Page: 14
4 WHAT INSIDE IN THE BOX
Standard Custos BVS package comes with below items
A. Custos BVS Main Unit x 1
B. AC-DC Adaptor x 1, (AC 110/220V to DC 12V/1A)
C. Local Leak Sensor Probe x 1 (Optional)
A
B
C

BVS-ZWx User Manual Date:02-APR-2020
Ubitech Ltd. Ve rs io n: 0 .9 .4
Page: 15
5 UNDERSTANDING CUSTOS BVS
5.1 Connectors & Interfaces
Terminology
Description
Terminology
Description
○
a Touch Sense Button
Network, Water Valve and Alarm operations
○
g Leak Sensor Connector
Local Leak Sensor Probe
○
b Display Indicators
3 Colors LED with Green, Yellow & Red
○
h Knob
Use to adjust Fork widths
○
c Sound Indicator
Buzzer
○
i Fork
Mount on valve handler, max 1” width
○
d Temperature Sensor
Built-in Temperature Sensor
○
j Clamp
Mount on water pipe. “Max 1 1/4” diameter”
○
e QR Code & Product
Z-Wave SmartStart and Product Label
○
k Dust Cover
Prevent Dust and Water
○
f Power Connector
DC 12V / 1A in
○
l Serial Number
Serial Number Label
○
b
LED Indicator
○
c
Buzzer
○
d
Temperature
Sensor
○
a
Touch Sense
Button
○
h
Knob
○
g
Leak Sensor
Connector
○
f
DC 12V in
Connector
○
k
Dust Cover
○
e
SmartStart
2.5” ~ 4.9”
Max.
0.7”
Max.
1.0”
○
i
Fork
○
j
Clamp
○
l
Serial
Number

BVS-ZWx User Manual Date:02-APR-2020
Ubitech Ltd. Ve rs io n: 0 .9 .4
Page: 16
6 KEY & INDICATORS BEHAVIOR
6.1 Touch Sense Button
- Short Press: One click comes with one short beep sound.
- Long Hold: Press and holding the key. “Come with 1 x short beep per second”
6.2 Visual Indicator
- 3 Colors LED: GREEN, YELLOW & RED
- ON Event: ON, quick blinking and slow blinking
6.3 Sound Indicator
- Buzzer: Long & short beep sound.

BVS-ZWx User Manual Date:02-APR-2020
Ubitech Ltd. Ve rs io n: 0 .9 .4
Page: 17
7 PHYSICAL INSTALLATION
7.1 Quick Installation Instruction:
- Make sure to disconnected the power.
- Place the Valve Handle in Close position.
- Choose right size Fork of BVS and aligning with Valve Handle. *Refer to “Figure A”
- Make sure the Knob and Valve Handle are facing on same side. *Refer to “Figure B”
- Tighten Clamps while holding down the Custos BVS.
- Unplug the Dust Cover and plug Local Water Sensor Probe into connector tightly. (Optional) *Refer to Figure C
- Connect the power socket to DC Adaptor, screw up the water seal cover.
- Plug DC Adaptor into AC Power Outlet.
Figure A
Figure B
Leak Sensor
Connector
Local Water
Sensor Probe
Dust Cover
Figure C
Power socket

BVS-ZWx User Manual Date:02-APR-2020
Ubitech Ltd. Ve rs io n: 0 .9 .4
Page: 18
8 WORKING MODE SUPPORT
8.1 Standalone Mode
- Support Water Valve Operation, Water Leak detection & Alarm, Inclusion, Exclusion and Factory Default Reset.
- By default, Custos BVS is in Standalone Mode with Factory Default Setting and it’s not belonged to any Z-Wave Mesh
Network.
- End user can enjoy all regular functions without Z-Wave benefit. Such as Water Valve, Leak detection by Local Leak
Sensor Probe.
8.2 Mesh Network Mode
- Support Smart Start, Classis Inclusion, Exclusion & Factory Default Reset.
- After Adding Custos BVS to a Z-Wave Mesh Network, end-customer can fully enjoy all functionalities, such as remote
control, associate with other Z-Wave end devices…
8.3 Water Valve
- Support OPEN, CLOSE, PAUSE
- RESUME during OPEN/CLOSE operation.
- Auto-calibration position of valve handle. (Only support operate by Touch Sense Button)
- Water Valve will be closed automatically once Local Water Leak Sensor Probe is triggered.
- Water Valve can be triggered with associated other Z-Wave end-devices. (Only in Mesh Network Mode)
8.4 Water Leak Sensor & Alarm
- Water Leak Alarm will be activated and to CLOSE Water Valve automatically once Local Water Leak is detected.
- Once Local Water Leak is detected then Custos BVS will also send out Water Leak Alarm with no location support to
Z-Wave Gateway. (Only in Mesh Network Mode)
8.5 Temperature Sensor
- By default, BVS sends temperature report automatically to gateway when every 1°C or 1.8°F degree changed. (Only in
Mesh Network Mode)

BVS-ZWx User Manual Date:02-APR-2020
Ubitech Ltd. Ve rs io n: 0 .9 .4
Page: 19
9 TOUCH SENSE BUTTON KEYLOCK
Custos BVS is capable for outdoor deployment. To prevent mis-operation by rain drop, end-user can
enable Touch Sense Button Keylock function.
9.1 Touch Sense Button Keylock Enable
After enabled Touch Sense Button Keylock function, Custos BVS will not accept any key event excepting Touch Sense
Button Keylock Disable function. (Refer to 8.2)
i. Start: Long hold Touch Sense Button 3 seconds then short click 3 times.
ii. Process: Yellow LED on 1 second then Red LED on 1 second with 1 beep sound.
iii. Success: Yellow LED slow blinking.
9.2 Touch Sense Button Keylock Disable
i. Start: Long hold Touch Sense Button 3 seconds then short click 3 times.
ii. Process: Yellow LED on 1 second then Red LED on 1 second with 3 beep sounds.
iii. Success: LED indicator resume previous status. (Yellow LED blinking or Green LED slow blinking)

BVS-ZWx User Manual Date:02-APR-2020
Ubitech Ltd. Ve rs io n: 0 .9 .4
Page: 20
10 SETUP Z-WAVE NETWORK
10.1 Check Custos BVS Status:
- Before Adding into Z-Wave Network, you have to make sure Custos BVS is in Standalone mode.
- By default, Custos BVS does not belong to any Z-Wave Network and color indicator is keeping in Yellow Blinking.
*If not, please perform “Factory Default Reset - refer to 10.4” or “Remove from Z-Wave Network – refer to 10.3”
10.2 Add Custos BVS into Z-Wave Network:
Custos BVS supports Security 2 Command Class while a Security S2 enabled controller is needed. SmartStart or Classis
Inclusion, you can use either of these modes. It supports
- SmartStart:
Custos BVS comes with DSK Code, end-user by scanning the QR code or entering first 5 digits during inclusion is
processing that shows in DSK Code label.
- Classic Inclusion:
Set your Z-Wave Gateway into Inclusion mode / Add device.
i. Start: Short press Touch Sense Button 3 times.
ii. Processing: Yellow LED and short beep sound keeping continue. For security inclusion support, you may need to entering
first 5 digit that show on QR Code label, please refer to the instructions of central controller.
iii. Success: Green LED on 1 second with 2 short beep sounds.
iv. The LED indication changes to Green LED slow blinking from Yellow LED blinking.
10.3 Remove Custos BVS from Z-Wave Network:
Set your Z-Wave Gateway into Exclusion mode / Remove device.
i. Start: Short press Touch Sense Button 3 times.
ii. Processing: Yellow LED and short beep sound keeping continue.
iii. Success: Green LED on 1 second with 2 short beep sounds.
iv. The LED indication Changes to Yellow LED blinking.
This manual suits for next models
2
Table of contents
Other UbiTech Control Unit manuals
Popular Control Unit manuals by other brands

POLNA
POLNA BR 33 Installation, operation and maintenance manual

NI
NI 9217 Getting started guide

Balluff
Balluff BNI PBS-507-001-Z011 user guide

Sony
Sony CCU-50P Operation instructions

Rockwell Automation
Rockwell Automation Allen-Bradley PowerFlex 750 ATEX Series user manual

Parker
Parker PSSN8M8A Installation & service instructions