UIS NGW-240 User manual

1
2
Quick Install Guide
USB USB
LAN
WAN
DC IN 12V
SET
WPS
AWAY STAY
USB USB
LAN
WAN
DC IN 12V
SET
WPS
SET button
SET button
Gateway Panel Console
CO2
Contact Sensor and other devices
Power Switch
AWAY
STAY
SET/Reset Reboot
SET button
SET
SET button
SET
ALARM
CO
2
Monitor
push and hold “▲” & “▼”
together until the screen blinks
Connect to
NGW-240…
Power On
Device Joining
Gateway
2.1 Gateway vs ALL RF devices
1. Short press the SET button at the back of the Gateway. Wait until the Alarm LED blinks red before releasing
the SET button.
2. Short press the SET button at the back of the device until the LED blinks green.
3. Wait for few seconds until both LEDs (on the Gateway and device) turned off. This indicates the binding
process is successful.
2.2 Router(Power Switch) vs ALL RF devices
1. Short press the SET button on the Power Switch until the LED blinks green.
2. Short press the SET button at the back of the device until the LED blinks green.
For CO2sensor, press both the and buttons until the screen blinks.
3. Wait for few seconds until both LEDs (on the Router and device) turned off. This indicates the binding
process is successful.
Note:
• RF devices are including Sensor, Console, Switch, and Transducer.
Panel Console Contact Sensor
Plug in the power adapter or insert the battery.

3
Quick Install Guide
1.8~2.4m
80
80
70
70
60
60
50
50
40
40
30
30
20
20
10
10
0
A
B
012345678910 11 12 13
(M)
012345678910 11 12 13
(M)
AB
1
2
2m
(M)
Distance:10m
Detection area : (Unit=Meter)
10mm
On-Site Installation
3.1 Panel Console(keypad)
1. Mount the bracket on the wall at an appropriate height.
For easy access, it is recommended to install the device near the front gate.
2. Open the battery cover and install the batteries into the battery
compartments. Then close the bottom cover firmly.
Note:
• The device supports both city power and battery (alkaline AA battery x 2,
non-rechargeable, for 2 hours emergency use).
• Once CPN-240 is unexpectedly unplugged from the bracket under system
arm mode, the tamper-proof detection will trigger the alarm.
3.2 Contact Sensor
1. Mount the bracket on the frame side of the door or
window, and then put the reed on the bracket.
2. Place the magnet on the door or window side. Align
the arrow point of the reed by less than 10mm
distance. Then stick on it.
Note:
• Due to tamper-proof design, please make sure the
installation is stable to avoid any false alarm.
3.3 Motion Sensor
1. Mount the bracket on the wall, at the height of 1.8 to
2.4 m. Do not install it upside down.
2. The scan pattern is illustrated in the figure on the
right.
• The effective distance is 8~10m, at 2m height.
• 150-degree at horizontal position.
• 25-degree at vertical position.
3. Pet immune detection could be effective if it meets
the following criteria:
• Height: less than 50cm.
• Weight: less than 6kg.
4. To avoid false alarm, do the following:
• Be sure the installation is stable.
• Do not place the device to face any light source
directly.
• Never face the sensor to the place that pests can
climb up directly.

3
Quick Install Guide
SET
ALARM
CO
2
Monitor
LED button
Socket
LED button
Buzzer
On-Site Installation
3.4 Smoke Sensor
1. Install the batteries into the battery compartments and close the bottom
cover firmly.
2. Mount the bracket on the ceiling. When the sensor detects the smoke, it will
automatically trigger the alarm and also send out the signal to the Gateway.
To manually turn off the alarm sound, push the button on the front side of
the sensor.
Note:
• Because of fool-proof design, install in the battery first before closing the
case by turning the cover counterclockwise.
3.5 RSSI - RF signal test
Short press the SET button at the back of the sensor twice.
The signal strength is indicated by its LED indicator:
*Good: The LED blinks green (very quickly) for 15 seconds
*Normal: The LED blinks green (quickly) for 15 seconds
*Poor: The LED blinks green (slowly) for 15 seconds (not recommended)
*No Signal: The LED blinks red light for 3 seconds then turned off (not recommended)
It is highly recommended to install the devices at “Good” or “Normal” signal strength to ensure a good
quality wireless signal.
Note:
• RSSI devices are including Button Console, Contact Sensor, Motion Sensor, Smoke Sensor,
AI Transducer, DI Transducer, and Siren.
3.6 CO2Sensor
1. Hang it on the wall through the rear holds or place it on a stable
surface.
Note:
• It is recommended to place the device inside the room to
detect the CO2concentration. It also supports both
temperature and humidity detection.
2. Push the SET button and then press both the and buttons
to set up the concentration threshold.
3.7 Alarm Switch(Siren)
1. Power on the device either by using the power adapter or
installing the battery.
2. Once the alarm is triggered, the alarm volume is approximately
90dB. To turn off the alarm sound, press the upper LED button.
3.8 Power Switch
1. Plug it into a wall socket and connect to any household
appliance with less than 10A.
2. Press the LED button to manually turn on/off the power relay.
Note:
• Tamper-proof function is only available for Panel Console, Contact Sensor, Motion Sensor, and Siren.
• Alarm switch (siren) is highly recommended to be joined/installed at last to avoid the false alarm caused by
unexpected tamper-proof.

4
7
6
5
Quick Install Guide
AWAY
STAY
SET/Reset Reboot
SET button
SET
SET button
LED
[■■■■■]
Reseting
Push and hold
“▲” button
SET
ALARM
CO
2
Monitor
USB USB
LAN
WAN
DCIN 12V
SET
WPS
SET button
AWAY FUNC
STAY AWAY STAY
Reset to Default
4.1 Gateway
a. Push and hold the SET button for 15 seconds until the ALARM LED blinks red.
OR
b. Access the Web Management and select System > Reset.
Note:
• If the Gateway is turned off while doing the reset process, the device will be
displayed as “off-line” on the Web Management when the gateway is turned on
on the next time. In this case, you have to delete the device one by one via Web
Management.
4.2 Panel Console(keypad)
1. Push and hold the SET button until the screen shows “Reseting”.
2. Wait until the “CPN-240 Reset OK!” message appears on the screen and
then the device will automatically reboot. After booting, it will show “Welcome
to CPN-240!” for few seconds, indicating the device has been reset to the
factory default successfully.
Note:
• You cannot reset the panel console while arming.
4.3 Device(sensor, switch or transducer)
1. Push and hold the SET button at the back of the sensor for 5 seconds.The
LED will blink green at the same time and then turn off.
2. After 2~3 seconds, the LED will blink red and then turn off to complete the
reset process.
Get connected with Gateway by Wi-Fi Interface
The gateway supports Wi-Fi connectivity with basic AP function and the default SSID is “HOME-AP”.
1. Open the Wi-Fi interface on the notebook or tablet PC to search the SSID as above to get connected.
2. Open browser (IE 7.0 or above) and enter the default IP “192.168.19.254” to get connected with the Gateway by
login default password “123”.
Full Arm / Partial Arm / Disarm / Panic Operation
Use the combination keys to operate the system using Panel Console(keypad) or Button Console(key-fob) without
accessing the Web Management or APP.
Operation Full Arm Partial Arm Disarm Panic
Panel Console + Password + Password or + Password Long press
Button Console Press “FA” Press “PA” Press “DA” Long press “FA”
Get connected with Gateway by Wired Ethernet Interface
Make sure the type of network connection that you are using is DHCP.
1. Connect the LAN ports of the Gateway and notebook using an Ethernet cable.
2. Open browser (IE 7.0 or above) and enter the default IP “192.168.19.254” to get connected with the Gateway by
login default password “123”.
REFER TO THE USER’S MANUAL FOR MORE INFORMATION.
4.4 Device(CO2Sensor)
Push and hold the button for 5 seconds.The LED will quickly blink once to
complete the reset process.
Table of contents
Other UIS Gateway manuals
Popular Gateway manuals by other brands

Barracuda
Barracuda WSG quick start guide

Topex
Topex TOPEX MobiLink IP user manual

ELTEX
ELTEX TAU-4M.IP Operation manual

Memotec
Memotec NetPerformer SDM-9220 Series Hardware installation guide

Avaya
Avaya IG550 Installing and configuring

ZyXEL Communications
ZyXEL Communications P-660HW-DX V2 - V3.40 quick start guide

Shenzhen Sailwider Electronics Co., Ltd.
Shenzhen Sailwider Electronics Co., Ltd. RCS-Z31C Product specification

Medic4All
Medic4All MiniGate VMG03 product manual

urmet domus
urmet domus 4203 user manual

BAPI
BAPI 900 MHz WAM Connect Installation and user guide

Silicon Laboratories
Silicon Laboratories ZigBee RD-0001-0201 user guide

Media5
Media5 Mediatrix C710 installation manual