Ultralife CH0002 User manual

CH0002 Battery Charger
Operation Manual
CH0002 Operation Manual
Newark, New York |315-332-7100 |Fax: 315-331-7800
©2011 Ultralife Corporation • www.ultralifecorp.com • All information is subject to change without notice
The information contained herein is for reference only and does not constitute a warranty of performance • 11 AUG 11 UBI-5133 Rev: D
Ultralife Corporation
2000 Technology Parkway, Newark, NY 14513 USA
Telephone: (315) 332-7100 FAX: (315) 331-7800
E-MAIL: sales@ulbi.com
www.ultralifecorporation.com

CH0002 Operation Manual
Newark, New York |315-332-7100 |Fax: 315-331-7800
©2011 Ultralife Corporation • www.ultralifecorp.com • All information is subject to change without notice
The information contained herein is for reference only and does not constitute a warranty of performance • 11 AUG 11 UBI-5133 Rev: D
Page 2 of 5
Copyright
Copyright © 2011, Ultralife Corporation. All Rights Reserved.
Disclaimer of Liability
Information and descriptions contained in this manual are the property of Ultralife Corporation.
Distribution and/or reproduction in part or in whole are expressly forbidden without written
consent.
Ultralife Corporation believes that information in this publication is accurate as of its publication
date. Ultralife Corporation reserves the right to change the contents without prior notice and is not
responsible for any inadvertent errors.
Ultralife Corporation
2000 Technology Parkway
Newark, New York 14513
Phone: (315) 332-7100
Fax: (315) 331-7800
Email: sales@ulbi.com
www.ultralifecorporation.com

CH0002 Operation Manual
Newark, New York |315-332-7100 |Fax: 315-331-7800
©2011 Ultralife Corporation • www.ultralifecorp.com • All information is subject to change without notice
The information contained herein is for reference only and does not constitute a warranty of performance • 11 AUG 11 UBI-5133 Rev: D
Page 3 of 5
CONTENTS
1. Before You Begin.....................................................................................................4
2. Function...................................................................................................................4
3. Connection Instructions............................................................................................4
4. Charging ..................................................................................................................5
5. Maintenance Charging.............................................................................................5
6. Error Conditions.......................................................................................................5
7. Status Light Indications:...........................................................................................5
8. Charger Specifications:............................................................................................5

CH0002 Operation Manual
Newark, New York |315-332-7100 |Fax: 315-331-7800
©2011 Ultralife Corporation • www.ultralifecorp.com • All information is subject to change without notice
The information contained herein is for reference only and does not constitute a warranty of performance • 11 AUG 11 UBI-5133 Rev: D
Page 4 of 5
U
SE ONLY WITH
UBI-2590
(UBBL02,
UBBL10,
UBBL13)
L
ITHIUM
-I
ON
B
ATTERY
1. Before You Begin
1.1. The charger consists of three parts: a line cord, a power supply (PS2524), and a charge control
module that has a charge cable attached. Make certain the line cord is the proper type for your
application (i.e. the plug is correct for your wall outlet.)
1.2. The charger is designed for use between 0°C an d 45°C (32°F and 113°F.) Failure to operate
charger in this range will result in reduced battery capacity and/or ability of safety devices to
activate.
2. Function
2.1. The charger is designed to charge each section of any UBI-2590 battery independently. This
assures that the two sections of the battery are both fully charged and assists in maintaining
proper charge balance within the battery.
3. Connection Instructions
3.1. Connect the line cord to the power supply.
3.2. Connect the power supply to the charge control module.
3.3. The charge control module has a built-in mating connector that will connect to any of the UBI-
2590 batteries. Carefully orient the connector so that Pin 1 matches Pin 1 on the battery
connector. Press the connector firmly into the battery.
NOTE: Although the connector is keyed, failure to orient it properly can cause damage to battery
and/or charger.
3.4. The charger will automatically detect the presence of a connected battery and initiate the
charging sequence. This is identified by the blinking green lights on the charger.

CH0002 Operation Manual
Newark, New York |315-332-7100 |Fax: 315-331-7800
©2011 Ultralife Corporation • www.ultralifecorp.com • All information is subject to change without notice
The information contained herein is for reference only and does not constitute a warranty of performance • 11 AUG 11 UBI-5133 Rev: D
Page 5 of 5
4. Charging
4.1. The charger will charge both battery sections until each section is fully charged. The green lights
will blink during charging.
4.2. Once charging is completed, the green lights will stop flashing and remain solid.
4.3. Each battery section may complete charging at different times, which is due to small differences
in capacity between the battery sections. Wait for both green lights to remain solid before
removing the battery from the charger.
5. Maintenance Charging
5.1. If left connected to the battery, the charger will initiate a low rate charge every 24 hours to
maintain a fully charged battery.
6. Error Conditions
6.1. If an error condition is detected the red light will blink.
7. Status Light Indications:
7.1. Off - No battery detected
7.2. Green blinking - Charging
7.3. Green steady on - Charging Complete
7.4. Red blinking Error: Shorted terminals or invalid battery chemistry
8. Charger Specifications:
8.1. See UBI-5134