Ulvac STC-1C Series User manual

D/N.MFST10CE,2022DR08 ULVAC CRYOGENICS INCORPORATED
SUPER TRAP TEMPERATURE
CONTROLLER
STC-1C series
Instruction Manual
STC-1C
STC-1C(INV)
Export Control Policy
We recommend that ALL customers be sure to follow all
rules and regulations such as Foreign Exchange and
Foreign Trade Law when exporting or reexporting our
products.


MZ0F001E,2013OR03 ULVAC CRYOGENICS INCORPORATED F-1
Introduction
Thank you for choosing our products. This instruction manual gives
information and precautions on handling, installation, operation, and
maintenance of the product.
This product is intended for use by qualified personnel who recognize shock
hazards and are familiar with the safety precautions required to avoid possible
injury. To ensure proper use of this product, read this instruction manual
carefully and keep this manual close at hand so that you can use for reference
during operation.
If you purchased our other products and/or optional devices with this product,
read relevant instruction manuals carefully.
1. About the personnel who are involved in handling our products
All personnel involved in handling our products should take a general safety
education and training that is officially accepted in the country where our product
is used. The personnel are also required to have specialized knowledge/skills and
qualification on the electricity, the machinery, the cargo handling, and the vacuum.
Especially, the personnel should be familiar with handling a cryopump in order to
use it safely. Since we offer a training session (which is subject to fees) as needed
for people who use cryopumps for the first time, please do not hesitate to contact
our Service Engineering Division to join the training session.
2. Warranty
2.1 Gratis warranty period and Warranty coverage
【Gratis warranty period】
Note that an installation period of less than one year after installation in your
company or your customer’s premises or a period of less than 18 months (counted
from the date of production) after shipment from our company, which is shorter, is
selected.
【Coverage】
(1) Failure diagnosis
As a general rule, diagnosis of failure should be done on site by customer.
However, ULVAC CRYOGENICS or our service network can perform this service
for an agreed fee upon the customer’s request. There will be no charge if the cause

F-2 ULVAC CRYOGENICS INCORPORATED
of the breakdown is found to be a fault of ULVAC CRYOGENICS.
(2) Damage during transportation
When damage by delivery/transportation is admitted, the product will be
repaired free of charge within the range of the guarantee expressed in the sales
contract.
(3) Breakdown repairs
There will be a charge for breakdown repairs, replacements and on-site visits
for the following seven conditions. In those cases the cost shall be your own
expense even though the product is within the warranty period.
①Breakdowns due to improper storage or handling, careless accident, software
or hardware design by the customer.
②Breakdowns due to modifications of the product without consent of the
manufacturer.
③Breakdowns due to maintenance of the product without authentic parts or
breakdowns resulting from using the product outside the specified
specifications of the product.
④Breakdowns due to contamination or corrosion caused by user’s use
conditions.
⑤Breakdowns due to natural disasters (such as fire, earthquake, flood,
lightning, salt damage, and so on) , environmental pollution, irregular voltage,
and /or usage of undesignated power source.
⑥Breakdowns that are outside the terms of warranty.
⑦Consumables and/or replacement service.
Since the above services are limited to within Japan, diagnosis of failures, etc are
not performed abroad. If you desire the after service abroad, please contact
ULVAC CRYOGENICS and consult us for details in advance.
2.2 Exclusion of opportunity loss from warranty liability
Regardless of the gratis warranty term, compensation to opportunity losses
incurred to your company or your customers by failures of ULVAC CRYOGENICS
products and compensation for damages to products other than ULVAC
CRYOGENICS products and other services are not covered under warranty.

MZ0F001E,2013OR03 ULVAC CRYOGENICS INCORPORATED F-3
2.3 Repair period after production is discontinued
ULVAC CRYOGENICS shall accept product repairs for seven years after
production of the product is discontinued.
3. Service Form
After the products are delivered, please fill out the following information in the
blanks. If you have any questions or technical problems, please feel free to contact
the nearest Customer Support Center or headquarters. Please refer to “Service
Network”.
Cryopump/Super trap Model :
Cryopump/Super trap Serial No. :
Refrigerator Model :
Refrigerator Serial No. :
Compressor Model :
Compressor Serial No. :
Temperature controller/Thermal display Model :
Temperature controller/Thermal display Serial No. :
Option Part Model :
Optional Part Serial No. :
4. Notes for repair and maintenance requests
We may decline your request for the repair or the maintenance of our products if
you refuse to give us information about the presence of the hazardous substance
and/or contaminant.
Also, please be aware that we do not accept liability for damages by the
contaminant, which might be caused during transportation to our office or the
nearest customer support center. To avoid such accident, please pay careful
attention to packing of the product
5.In case of breakdown and accident
When breakdown or accident occurs, we may ask for keeping the product on site
as it is or retrieving the product to investigate its cause. Also we may ask for
reporting the detailed process and/or the operating condition. When unidentified
malfunction was generated, please contact our Service Engineering Division or

F-4 ULVAC CRYOGENICS INCORPORATED
the nearest customer support center with reference to the chapter of Service
Network. We ask for cooperation about the above.
6.General Precautions
(1) It is strictly prohibited to duplicate, open, and transfer this instruction
manual or any of its parts to a third person without written permission from
ULVAC CRYOGENICS.
(2) Information in this document might be revised without a previous notice for
the specification change and the improvement of the product.
(3) If you have any questions or comments on this document, please do not
hesitate to contact us. The phone numbers of local customer support centers
are listed at the end of this manual.

MZ0F001E,2013OR03 ULVAC CRYOGENICS INCORPORATED F-5
Safety Considerations
Our products have been designed to provide extremely safe and dependable operation
when properly used. Following safety precautions must be observed during normal
operation and when servicing them.
CAUTION
WARNING
A warning describes safety hazards or unsafe practices
which could result in severe injury or loss of life.
Acaution describes safety hazards or unsafe practices which
could result in personal injury or equipment damage.
Toxic gas or chemicals used.
There is a risk of severe injury upon contact.
Corrosive chemicals used.
There is a risk of severe injury upon contact.
Flammable gas used.
There is a danger of fire or burn injury.
Explosive gas used.
There is a risk of fire or explosion.
Hazardous voltage .
Electric shock may cause severe injury or loss of life.
Hot heating part present.
There is a risk of burn injury.

F-6 ULVAC CRYOGENICS INCORPORATED
This page intentionally left blank

Super Trap Temperature Controller (STC-1C series) Instruction Manual
ULVAC CRYOGENICS INCORPORATED I
TABLE OF CONTENTS
Disposal Consideration................................................................................................... IW-1
1. Features and Types ....................................................................................................... 1
1.1. Features .................................................................................................................. 1
1.2. Types........................................................................................................................ 1
2. Specifications ................................................................................................................. 2
3. Component Descriptions ............................................................................................... 3
3.1. STC-1C .................................................................................................................... 3
3.2. STC-1C(INV)........................................................................................................... 4
4. Connector specifications................................................................................................ 5
4.1. STC-1C .................................................................................................................... 5
4.2. STC-1C(INV)........................................................................................................... 6
5. Accessories or Optional cable........................................................................................ 7
6. Installation..................................................................................................................... 9
6.1. Installation site....................................................................................................... 9
6.2. Installation.............................................................................................................. 9
7. Wiring ............................................................................................................................11
8. Operation...................................................................................................................... 16
9. Parameter setting........................................................................................................ 18
9.1. Procedure to Set Parameters............................................................................... 18
9.2. Initial setting ........................................................................................................ 19
10. Troubleshooting............................................................................................................ 20

Table of Contents
II ULVAC CRYOGENICS INCORPORATED
FIGURES
Figure 1-1 The appearance of STC-1C series........................................................... 1
Figure 1-2 Types of STC-1C series............................................................................ 1
Figure 6-1 Panel cut dimensions and installation method ..................................... 9
Figure 7-1 STC-1C optional cables wiring.............................................................. 14
Figure 7-2 STC-1C(INV) optional cables wiring.................................................... 15
Figure 8-1 STC-1C series operation........................................................................ 17
Appended Figure 1 STC-1C external dimensions drawing.................................. 21
Appended Figure 2 STC-1C (INV) external dimensions drawing ....................... 22
Appended Figure 3 STC-1C electric wiring diagram............................................ 23
Appended Figure 4 STC-1C (INV) electric wiring diagram ................................. 24
TABLES
Table 3-1 STC-1C Component Descriptions ......................................................... 3
Table 3-2 STC-1C(INV) Component Descriptions.................................................. 4
Table 4-1 Connectable plug types and descriptions of pins(STC-1C)................... 5
Table 4-2 Connectable plug types and descriptions of pins(STC-1C(INV)) ......... 6
Table 5-1 STC-1C series accessories ....................................................................... 7
Table 5-2 Optional cables......................................................................................... 8
Table 8-1 Operation................................................................................................ 16
Table 8-2 Description of contact output operation............................................... 16
Table 9-1 Parameter factory setting value ........................................................... 19
Table 10-1 Troubleshooting list ............................................................................... 20

Super Trap Temperature Controller (STC-1C series) Instruction Manual
ULVAC CRYOGENICS INCORPORATED III
SHIPPING LIST
Our product has been fully inspected before shipment. However, please make
sure that there is no shortage of delivered items by checking the table below,
product name, and there is no damage by checking the external view of the
products. STC-1C series has the name of product on the front of its body. Be sure
that the product is exact specifications of your order. Please inform us the name
of product and serial number when you inquire us about the product.
※1This conversion adapter comes with STC-1C series’ in the only case Super trap
refrigerator is two phase motor, and is delivered with the condition the conversion
adapter connected with the main body of STC-1C series.
Item Quantity
Super trap temperature controller STC-1C Series
1
Fixed clamp (Refer to section.5, chart 5-1) 2
Power Cable (Refer to section.5, chart 5-1) 1
Conversion adapter (Refer to section.5, chart 5-1)
1※1
Optional cables (Refer to section.5, chart 5-1) 1
Instruction Manual 1
Inspection and Adjustment of STC-1C series
Please contact our technical service department when inspection and/or adjustment
of STC-1C series are needed. No circuit or any other parts of this product may be
changed and/or adjusted in any shape or form in any circumstances. Note that any
inspection, check, adjustment and repair caused by such change and/or adjustment
will be only accepted at your expense even if it is within the warranty period.

Table of Contents
IV ULVAC CRYOGENICS INCORPORATED
This page intentionally left blank.

MZIW002E,2018JE01 ULVAC CRYOGENICS INCORPORATED IW-1
Disposal Considerations
Disposal of our products must be done in accordance with applicable national and local
laws and regulations.
We provide Safety Data Sheet (SDS) of our products upon your request.
Please contact us if necessary.
WARNING
The cryopumps or cryocoolers may contain residue of hazardous substances resulting
from actual use. Contact your safety supervisor and follow the instructions to remove
such toxic substances before disposing.

IW-2 ULVAC CRYOGENICS INCORPORATED
This page intentionally left blank.

Super Trap Temperature Controller (STC-1Cseries) Instruction Manual
ULVAC CRYOGENICS INCORPORATED 1
1. Features and Types
1.1. Features
Super Trap Temperature Controller STC-1C series can display the temperature of 80K
panel by means of connecting K thermocouple mounted on our CRYO-T Super Trap
series, and can adjust the temperature of 80K panel within the range of setting
temperature by means of turning the trap refrigerator power ON and OFF. The
appearance of STC-1C series is shown on Figure 1-1 below.
This series has two types: STC-1C and STC-1C (INV). The main difference between
them is how to control refrigerator power. STC-1C is a relay control method: it is
connected between the compressor unit and the refrigerator, and turn refrigerator
power line ON and OFF by relay. On the other hand, STC-1C (INV) is an inverter
control method: it controls On command of refrigerator with the inverter mounted on
the compressor as an optional. Figure 1-2 below shows types of STC-1C series.
Figure 1-1 The appearance of STC-1C series
1.2. Types
Figure 1-2 Types of STC-1C series
STC-1C( )
Control method for refrigerator power
Undescribed = relay control method
INV = inverter control method

Super Trap Temperature Controller (STC-1Cseries) Instruction Manual
2ULVAC CRYOGENICS INCORPORATED
2. Specifications
○Dimensions ........................... 96mm(W) x 96mm(H) x 238mm(D)
(Refer to the external dimensions for the details)
○Weight ................................... 1.6kg
○Input Power Source.............. Single-phase 100VAC - 220VAC±15% 50Hz/60Hz
(Note: Attached power source cable is for AC100V only.)
○Power Consumption ............. 30W
○Operating Environment....... Ambient Temperature:-10ºC - 40 ºC (No freezing.)
Ambient Humidity:Below 80%RH(No condensation.)
Ambient Altitude:Below 1000m
○Input...................................... TC-IN
K thermocouple input
REF-IN
Refrigerator(Cold head)power input:
144VAC - 240VAC (50Hz - 80Hz)
○Output................................... R-T,HI-TEMP,READY
Relay contact output:24VDC MAX 1A
REF-OUT
Relay output three-phase 144VAC-240VAC MAX 2A
TC-OUT
K thermocouple output
(Note: Not insulated from TC-IN. Insulation must
be done referring to Section 7 in case of using it.)
○Insulation Resistance........... DC 500V 20MΩor more
○Withstand Voltage ................ One minute at 1000VAC between input terminal and
earth terminal.
○Display .................................. 4 digit 7 segment Display
Display range:45K - 400K
Display accuracy:400K - 123K ±0.5%FS
123K - 73K ±3%FS
<73K Out of K thermocouple accuracy range
CAUTION
●Do not heat the Super Trap exceeding 70ºC(340K).
High temperature over 70ºC may cause a damage to the Super Trap.
●If you use STC-1C series with Heater mounted on the Super Trap, be sure to install a timer
device for the Heater in your equipment, or install thermocouple for overheat prevention to
avoid any damage to the Refrigerator of the Super Trap.

Super Trap Temperature Controller (STC-1Cseries) Instruction Manual
ULVAC CRYOGENICS INCORPORATED 3
3. Component Descriptions
3.1. STC-1C
Table 3-1 STC-1C Component Descriptions
Name
Description
①POWER The lamp lights up when powered ON.
②7-SEGMENT
DISPLAY
Normal Mode Displays the temperature of 80K panel.
Parameter Setting
Mode
Displays the set value.
(Refer to section 9.1)
③Status LED
・R-T The LED lamp lights up when contact outputs on the rear terminal board.
Refer to section 8 for operation and section 9.2 for factory default value.
・HI-TEMP
・READY
・REF ON The LED lamp lights up when the refrigerator is ON.
・REF OFF
The LED lamp lights up when the refrigerator is OFF.
(Note: The LED lamp doesn’
t light when the compressor unit is
suspended.)
④[UP]/[DN] Used when change the parameter setting.
Refer to “parameter setting method” of section 9.1 for the details.
⑤
ENT
STC-1C
K
UP
DN
ENT
POWER
REF OFF
REF ON
READY
R-T
HI-TEMP
12
345
ULVAC CRYOGENICS

Super Trap Temperature Controller (STC-1Cseries) Instruction Manual
4ULVAC CRYOGENICS INCORPORATED
3.2. STC-1C(INV)
Table 3-2 STC-1C(INV) Component Descriptions
Name
Description
①POWER The lamp lights up when powered ON.
②7-SEGMENT
DISPLAY
Normal Mode Displays the temperature of 80K panel.
Parameter Setting
Mode
Displays the set value.
(Refer to section 9.1)
③Status LED
・R-T The LED lamp lights up when contact outputs on the rear terminal board.
Refer to section 8 for operation and section 9.2 for factory default value.
・HI-TEMP
・READY
・REF ON The response varies depending on the inverter type.
FR-E720series:Lights at the temperature that the refrigerat
or unit is
turned ON while the compressor unit is in operation.
FR-D720series:
Lights at the temperature unit is turned ON while the
compressor unit is in normal condition(*1).
・REF OFF
The response varies depending on the type of the inverter to connect.
FR-
E720 series: Lights at the temperature that the refrigerator unit is
turned OFF while the compressor unit is in operation.
FR-
D720series: Lights at the temperature unit is turned OFF while the
compressor unit is in normal condition(*1).
④[UP]/[DN] Use these buttons to change parameter values.
Refer to section 9.1 ”Parameter setting“ for detail.
⑤
ENT
(*1) “Normal condition” refers to the state that the compressor unit is in operation and both the
compressor unit and the inverter have no alarm.

Super Trap Temperature Controller (STC-1Cseries) Instruction Manual
ULVAC CRYOGENICS INCORPORATED 5
4. Connector specifications
4.1. STC-1C
The drawing on the right and table 4-1 show
compatible connector types for STC-1C and
explanations of the pins
Table 4-1 Connectable plug types and descriptions of pins(STC-1C)
No. Name Connectable plug type Pin No. Descriptions
①SOURCE PRC03-12A10-3AF10.5
(TAJIMI)
1 L:Power source input
(Single-phase 100VAC~220VAC)
2 N:Power source input
(Single-phase 100VAC~220VAC)
3 E:Earth
②REF IN NJC-204-PF(NANABOSHI)
1 R:Refrigerator power source input
2 S:Refrigerator power source input
3 T:Refrigerator power source input
4 E Earth:
③REF OUT NJC-204-PM(NANABOSHI)
1 R:Refrigerator power source output
2 S:Refrigerator power source output
3 T:Refrigerator power source output
4 E:Earth
④TC-IN Round type crimping terminalφ
3
(width 6mm or less)
+ K Thermocouple input (+)
- K Thermocouple input (-)
⑤TC-OUT Same as above
+ K Thermocouple output (+)
- K Thermocouple output (-)
⑥R-T
Same as above Relay contact output:24VDC MAX1A
(Refer to section 8 for operation.)
⑦HI-TEMP
⑧READY
⑨FG Same as above Frame grand
SOURCE
+ - + -
TC‐IN TC‐OUT
REF OUT
REF IN
N/C
READYR‐T HI‐TEMP
3
1
28
67
5
4
9

Super Trap Temperature Controller (STC-1Cseries) Instruction Manual
6ULVAC CRYOGENICS INCORPORATED
4.2. STC-1C(INV)
Following drawing and table 4-2 show compatible connector types for STC-1C (INV),
and explanations of pins
Table 4-2 Connectable plug types and descriptions of pins(STC-1C(INV))
No. Name Connectable plug type Pin No. Descriptions
①SOURCE PRC03-12A10-3AF10.5
(TAJIMI)
1 L:Power source input
(Single-phase 100VAC~220VAC)
2 N:Power source input
(Single-phase 100VAC~220VAC)
3 E:Earth
②―――
③INV ON/OFF NCS-257-P(NANABOSHI)
1 R:COMP Operation signal
(200VAC) input
2 S:COMP Operation signal
(200VAC) input
5 SD:Refrigerator ON signal output
6 STF:Refrigerator ON signal output
④TC-IN Round type crimping terminalφ
3
(width 6mm or less)
+ K Thermocouple input (+)
- K Thermocouple input (-)
⑤TC-OUT Same as above
+ K Thermocouple output (+)
- K Thermocouple output (-)
⑥R-T
Same as above Relay contact output:24VDC MAX 1A
(Refer to section 8 for operation.)
⑦HI-TEMP
⑧READY
⑨FG Same as above Frame grand
3
1
2
8
6 7
5
4
+ - + -
TC‐IN TC‐OUT
N/C
READYR‐T HI‐TEMP
9
This manual suits for next models
2
Table of contents
Popular Temperature Controllers manuals by other brands

Sorel
Sorel TDC 3 Installation and operating instructions

Johnson Controls
Johnson Controls System 350 A350A Technical bulletin

ATC
ATC M910165 Operator instructions

Middleby Marshall
Middleby Marshall 37626 Installation, programming and troubleshooting instructions

Dinam Led
Dinam Led Dn-T2M manual

Brainchild
Brainchild BTC-2500 user manual