UniFi Switch Flex Mini Power Adapter (5V, 1A)*
Package Contents
* Included only in the single-pack of the USW-Flex-Mini.
System Requirements
Linux, Mac OS X, or Microsoft Windows 7/8/10
Java Runtime Environment 1.8 or above recommended
Web Browser: Google Chrome (Other browsers may have limited functionality)
UniFi Controller software v5.12.5 (or newer), available at:
ui.com/download/unifi
Hardware Overview
USW-Flex-Mini Quick Start Guide

18/10/21, 11:42
USW-Flex-Mini Quick Start Guide
dl-origin.ubnt.com/qsg/USW-Flex-Mini/USW-Flex-Mini_EN.html
2/8
System LED
RJ45 Link/Speed/Activity LED (Ports 1- 5)
PoE In Port
Flashing White Initializing.
Steady White Factory defaults, waiting for adoption.
Alternating White/Blue
Device is busy; do not touch or unplug it. This
usually indicates that a process such as a
firmware upgrade is taking place.
Steady Blue Successfully adopted by a network and working
properly.
Flashing Blue
This is used to locate a device.
When you click Locate in the UniFi Controller
software, the System LED will flash blue. The
software will also display the location of the UniFi
Switch on the map.
Off No Link
Amber
Link established at 10/100 Mbps
Flashing indicates activity
Green
Link established at 1000 Mbps (1 Gbps)
Flashing indicates activity
This RJ45 port supports a 10/100/1000 Mbps Ethernet connection and
802.3af/at PoE input.
USW-Flex-Mini Quick Start Guide

18/10/21, 11:42
USW-Flex-Mini Quick Start Guide
dl-origin.ubnt.com/qsg/USW-Flex-Mini/USW-Flex-Mini_EN.html
3/8
Ports 2 - 5
Power Port
Reset Button
RJ45 ports support 10/100/1000 Mbps Ethernet connections.
Connect the included Power Adapter to the Power port.
Resets to factory defaults. The device should be running after bootup is
complete. Press and hold the Reset button for about 10 seconds until the LED
starts flashing and then becomes solidly lit. After a few seconds, the LED will
turn off, and the device will automatically reboot.
Connecting Power
OR
Connecting Ethernet
USW-Flex-Mini Quick Start Guide

18/10/21, 11:42
USW-Flex-Mini Quick Start Guide
dl-origin.ubnt.com/qsg/USW-Flex-Mini/USW-Flex-Mini_EN.html
4/8
Software Installation
Download and install the latest version of the UniFi Controller software at
ui.com/download/unifi and follow the on-screen instructions.
Note: If you already have UniFi Controller v5.12.5 or newer installed, skip
to “Adopting the UniFi Switch”.
After you have installed the software and run the UniFi Installation Wizard, a login
screen will appear for the UniFi Controller management interface. Enter the admin
name and password that you created and click Sign In.
To adopt the UniFi Switch, proceed to “Adopting the UniFi Switch”.
You can manage your network and view network statistics using the UniFi
Network Controller management interface. For information on using the UniFi
Network Controller software, refer to the User Guide located on our website at:
ui.com/download/unifi
USW-Flex-Mini Quick Start Guide

18/10/21, 11:42
USW-Flex-Mini Quick Start Guide
dl-origin.ubnt.com/qsg/USW-Flex-Mini/USW-Flex-Mini_EN.html
5/8
Adopting the UniFi Switch
1. From the UniFi Controller dashboard, click Devices in the left menu bar.
2. On the Devices screen, locate the UniFi Switch in the list of devices under the
Model column. To adopt the UniFi Switch, click Adopt.
3. The System LED on the UniFi Switch will turn blue to confirm that it has been
successfully adopted.
Specifications
USW-Flex-Mini
Dimensions 107.16 x 70.15 x 21.17 mm
(4.22 x 2.76 x 0.83")
Weight 150 g (5.29 oz)
Networking Interfaces (5) 10/100/1000 Mbps RJ45 Ports
USW-Flex-Mini Quick Start Guide

18/10/21, 11:42
USW-Flex-Mini Quick Start Guide
dl-origin.ubnt.com/qsg/USW-Flex-Mini/USW-Flex-Mini_EN.html
6/8
USW-Flex-Mini
PoE In Interface 802.3af/at PoE (Pins 1, 2+; 3, 6-)
Max. Power Consumption 2.5W
Power Method USB Type C, 5V
802.3af/at PoE (44 - 57VDC, 0.05 - 0.04A)
Power Supply 5V, 1A Power Adapter*
Voltage Range
USB Type C 4.7 - 5.2VDC
802.3af/at PoE 44 - 57VDC
LEDs
System Status
RJ45 Data Ports Link/Speed/Activity
ESD/EMP Protection ± 16kV Air, ± 12kV Contact
Operating Temperature -5 to 45° C (23 to 113° F)
Operating Humidity 10 to 90% Noncondensing
Certifications CE, FCC, IC
* Included only in the single-pack of the USW-Flex-Mini.
Safety Notices
1. Read, follow, and keep these instructions.
2. Heed all warnings.
3. Only use attachments/accessories specified by the manufacturer.
WARNING: Failure to provide proper ventilation may cause fire hazard. Keep at
least 20 mm of clearance next to the ventilation holes for adequate airflow.
WARNING: To reduce the risk of fire or electric shock, do not expose this product to
rain or moisture.
WARNING: Do not use this product in location that can be submerged by water.
WARNING: Avoid using this product during an electrical storm. There may be a
remote risk of electric shock from lightning.
Electrical Safety Information
1. Compliance is required with respect to voltage, frequency, and current requirements
indicated on the manufacturer’s label. Connection to a different power source than those
specified may result in improper operation, damage to the equipment or pose a fire
hazard if the limitations are not followed.
2. There are no operator serviceable parts inside this equipment. Service should be
provided only by a qualified service technician.
USW-Flex-Mini Quick Start Guide

18/10/21, 11:42
USW-Flex-Mini Quick Start Guide
dl-origin.ubnt.com/qsg/USW-Flex-Mini/USW-Flex-Mini_EN.html
7/8
Limited Warranty
ui.com/support/warranty
The limited warranty requires the use of arbitration to resolve disputes on an individual basis,
and, where applicable, specify arbitration instead of jury trials or class actions.
Compliance
FCC
Changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions.
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause
undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
Consult the dealer or an experienced radio/TV technician for help.
ISED Canada
CAN ICES-3(B)/NMB-3(B)
Australia and New Zealand
CE Marking
CE marking on this product represents the product is in compliance with all directives that
are applicable to it.
USW-Flex-Mini Quick Start Guide
Table of contents
Other Uni-Fi Switch manuals