Uni-P Dry Vantix 3500 Operation manual

Uni-P Vantix 3500 AIR MOVERS
Installation, Operation & Service Instructions
Add: 4240 Latham Street, Suite D, Riverside, CA 92501
Tel: 888-990-7469
E-mail: sales@unipdry.com
READ AND SAVE THESE INSTRUCTIONS

Tel: 888-990-7469 Tel: 888-990-7469
Getting Started
The Unip Vantix 3500 air mover blows high velocity air mover wet surfaces to shorten the drying
time. In addition to accelerating evaporation, the 3500 also helps prevent mold and mildew. To
use the air mover, simply direct the air outlet to the targeted area.
Congratulations on purchasing a Unip vantix 3500 air mover. In order to take advantage of the
warranty plan, be sure to note the serial number and date of purchase.
12
Uni-P Vantix 950 AIR MOVERS Installation, Operation & Service Instructions Uni-P Vantix 950 AIR MOVERS Installation, Operation & Service Instructions
Do not adjust or alter the unit in.any.way. Only use the parts. approved by Unipdry Any
adjustments or use of unauthorized parts will void your warranty. For further assistance,
contact your dealer or distributor.
Do not let children play with unit. Always keep the unit out of reach of children.
Do not restrict airflow to unit.
Do not use unit with extension cords.
Do not use an external speed control device.
Do not drop or throw the unit. This could damage the inner parts and wiring.
Do not use the unit in standing water.
Do not use the unit outside as the internal components may get damp.
Do not use air mover with a malfunctioning outlet or plug.
Do not run power cord under carpet, runners, or other coverings.
While Operating the Unip vantix 3500:
Always use a grounding plug and grounded electric outlet to reduce risk of fire and shock
Always use caution when stacking units to prevent them from falling. Avoid stacking units in 'crowded areas.
Always secure units during transportation to prevent them from moving.
Always maintain a reasonable distance between the air inlet and carpet or other materials.
Failure to do so may clog the inlet or cause overheating.
Always keep the motor free of dirt, dust, and other particles that could cause the motor to overheat.
Clean the motor with a vacuum if it gets dirty.
Always unplug the machine before performing any maintenance.
Always contact an authorized technician for help repairing your machine.
Always use the unit on a level, steady surface.
Specifications
Safety Notes
NOTE: The Unip Vantix 3500 plugs into standard 115 VAC electrical outlets.
Each Unip Vantix 3500 air mover draws 2.3 amps and is equipped with a 12 amp circuit board. This
means that you can link up to 4 units to run on the same circuit. When daisy chaining the units, always
turn on one unit at a time rather than starting all units simultaneusly, which could cause the circuit to
short.
Unip Vantix
3500
Unip Vantix
3500
15Amp Outlet 15Amp Outlet
15Amp Outlet
Unip Vantix
3500
Unip Vantix
3500
Unip Vantix
3500
Unip Vantix
3500
Unip Vantix
3500
Unip Vantix
3500
Unip Vantix
3500
Unip Vantix
3500
Unip Vantix
3500
Unip Pro
200X Unip Renegade
140X

Tel: 888-990-7469 Tel: 888-990-7469
3 4
Uni-P Vantix 950 AIR MOVERS Installation, Operation & Service Instructions Uni-P Vantix 950 AIR MOVERS Installation, Operation & Service Instructions
Humidity Control
While using an air mover to dry the aîr, you may find out that the humidity is rising. To avoid this,
It is useful to pair the air mover with a dehumidifier. A dehumidifier can effectively control the
humidit level, while also reducing the drying time. For mold control, the ideal humidity level is
below 60% RH.
Temperature & Air Circulation
To cool down a warm room, place the Unip Vantix 3500 at the doors or in a cooler spot with air
directed at the hot area. If set up properly, the high velocity air from the machine can cool a room
down quite effectively.
Set Up
The Unip Vantix 3500 can be operated in multiple positions, depending on what direction you heed
to target the airflow.
Face Up -This position will direct air straight to the ceiling.

Tel: 888-990-7469 Tel: 888-990-7469
5 6
Uni-P Vantix 950 AIR MOVERS Installation, Operation & Service Instructions Uni-P Vantix 950 AIR MOVERS Installation, Operation & Service Instructions
Unipdry Warranty Steps:
1. Once receive the goods, customers must log in www.alorair.com to fill out the warranty registration form and submit to
Unipdry company. We will receive your purchasing and installation information and save it. If no warranty registration is
sent to us, warranty period will begin the day the shipment left the warehouse. Please be sure to record serial # and date
of installation. You will need this information to receive the RA number.
2. If warranty service is necessary, customers must contact Unipdry Tech Support by sales@unipdry.com or local technical
service phone to receive a Return Authorization (RA number). Once an RA has been issued, customers should bring the
unit to a certified repair center. Unipdry will arrange the shipping to bring the unit back to the warehouse (at the Unipdry
expense of the customers) if customers are not available.
3. After the unit has been received by (whether at a repair center or the warehouse), will have an initial Unipdry Unipdry
inspection. If it is determined to be invalid warranty claim (see exclusions below), customers have to pay for all associated
repair costs and shipping costs for units repair.
4. Customers can pick up the unit after repair at their own expense for shipping. Units will have a rigorous testing before
sending it back to customers
5. If the unit can no longer be fixed , and it is in the warranty period and determined to be valid claim, we will ship the
customer a new unit within the same year warranty from the date of replacement.
6. After parts are repaired or replaced by , the original warranty period continues to applies until meet its deadline. Unipdry
No extensions to the original warranty period.
Unipdry
Unipdry
Unipdry's
Unipdry
Unipdry

Black
Black
Black
Black
Black
Black
12 AMP
CIRCUIT
BREAKER
GND
White
White
White
WHITE
HOT
White
White
White
HOUR
Green
Green
LN
LINE
GFCI
LOAD
GND
FAN MOTOR
14 UF
Yellow
Yellow
Red
NEON LAMP
LOW
OFF
HIGH
POWR
110-120V/60Hz
Tel: 888-990-7469
Wiring Diagram
7
Uni-P Vantix 950 AIR MOVERS Installation, Operation & Service Instructions