Uni-P Dry Vantix 950 Operation manual

Uni-P Vantix 950 AIR MOVERS
Installation, Operation & Service Instructions
ADD: 2048 E. Francis St Ontario CA 91761
Tel: 888-994-0895
E-mail: Sales@unipdry.com
READ AND SAVE THESE INSTRUCTIONS

Important Safety Measures
The Installation, operation, and maintenance of the Uni-P Vantix 950 dehumidifier come along with
substantial electric shock-risks. It can cause property damage, death and/or injury. In order to reduce
exposure to the electric shock-risks you should observe the following instructions:
CAUTION:
You should never run the cord under the carpet. Makes sure that they are not covered with runners,
throw rugs or other suchlike coverings.
You should not route the cord under appliances or furniture. Make sure that the cords are located
away from traffic areas of the room and where they cannot be tripped over.
Make sure the cords and plugs are in a proper state and that they are neatly organized before
operating the dehumidifier.
You should never use a bench or stool when locating the device.
The device is suitable for indoor use only.
You should never block air outlet and intake. There should be at least a one-foot distance from the wall
or other forms of obstructions.
Make sure you first unplug the fan before you do any servicing.
Make sure that the dehumidifier is not exposed to rain or any stagnant water.
This type of device is not suitable for use near or together with the Solid-State Speed Controls
Tel: 888-994-0895 Tel: 888-994-0895
While Operating the Unip vantix 950:
Identification
Parts Identification
Always use a grounding plug and grounded electric outlet to reduce risk of fire and shock
Always use caution when stacking units to prevent them from falling. Avoid stacking units in 'crowded areas.
Always secure units during transportation to prevent them from moving.
Always maintain a reasonable distance between the air inlet and carpet or other materials.
Failure to do so may clog the inlet or cause overheating.
Always keep the motor free of dirt, dust, and other particles that could cause the motor to overheat.
Clean the motor with a vacuum if it gets dirty.
Always unplug the machine before performing any maintenance.
Always contact an authorized technician for help repairing your machine.
Always use the unit on a level, steady surface.
Congratulations on purchasing a Unip Vantix 950 air mover. In order to take advantage
of the warranty plan, be sure to note the serial number and date of purchase.
12
Uni-P Vantix 950 AIR MOVERS Installation, Operation & Service Instructions Uni-P Vantix 950 AIR MOVERS Installation, Operation & Service Instructions

Housing Disassembly
Tel: 888-994-0895 Tel: 888-994-0895
Operating Instructions
NOTE: Prior to use, verify that the power cord and plug are not broken.
Ensure the power switch is off, then unwrap the power cord and plug it into a standard 115V
GFCl-protected outlet.
Point the air outlet towards the area that needs to be dried.
Press the Up or Down button to adjust the airflow speed on the panel.
Once the surface is dry, turn the unit off and unplug the power cord.
Wrap the power cord around the machine in a clockwise direction and secure with a clip.
Use the handle to move the machine to the next drying area or to storage.
The units may be stacked for transportion or storage
NOTE:Always keep the units dry.
Citcuit Breaker Reset
The Unip Vantix 950 is equipped with a Circuit Breaker Reset Switch to protect from fire or
shock risk. The Circuit Breaker switch will:
Automatically cut off power to the machine if the circuit is overloaded
Automatically cut off power to the machine if it finds a ground fault
If reset switch is flipped, complete the following steps:
Check the power line for any damage and ensure it is properly connected to a grounded outlet
Press the Circuit Breaker Reset Switch to restart the unit
Maintenance
If dust or dirt has accumulated on the impeller, you will need to disassemble the housing
(see instructions on next page) to clean it. Do not use liquids to clean the impeller- only a
cloth on pressurized air. The housing can be cleaned with a damp, cloth but always ensure it
is dry prior to reassembling.
Cleaning the Housing & Impeller
3 4
Uni-P Vantix 950 AIR MOVERS Installation, Operation & Service Instructions Uni-P Vantix 950 AIR MOVERS Installation, Operation & Service Instructions

Tel: 888-994-0895 Tel: 888-994-0895
To disassemble the housing for cleaning, follow the steps below:
Housing Disassembly
1. Remove four screws on from impeller side.
2.Remove the six screws from the unit base, then lit off the housing.
Warranty
All warranty benefits apply to the original owner only. Warranty cannot be transferred or assigned.
1 Year (from date of purchase): Unipdry warrants the machine will operate free of defects in
workmanship and materials. At it's discretión, Unipdry will repair or replace any malfunctioning
components, free of charge (excluding transportation costs)
Customer Responsibilities: In order to take advantage of the warranty service, the customer
must do the following:
1.Custômer must provide normal care and maintenance (including, but not limited to
cleaning filters)
2. Removal and re-installation of unit is the sole responsibility of owner.
3. If customer cannot retumn unit to certified repair center, all costs associated with
shipment are borne by the customer. In additioni, all ancillary charges related to freight
shipments, including but not limited to palletizing, wrapping, labeling, and pickup are
associated with customer.
4. If shipped, customer is responsible for all risk of loss or damage.
Unipdry Warranty Steps:
1.Once réceive the goods, customers must log in www.unipdry.com to fill out the
warranty registration form and submit to unipdry company.We will receive your
purchasing and installation information and save it. If no warranty registration is sent
to us, warranty period will begin the day the shipment left the warehouse. Please be
sure to rerord serial # and date of installation. You will need this information to
receivethe RA number.
2.lf warrahty service is necessary, customers must contact Unipdry Tech Support by
sales@unipdry.com or local technical service phone to receive a Return Authorization (RA
number). Once an RA has been issued, customers should bring the unit to a certified repair
center.Unipdry will arrange the shipping to bring me the unit back to the Unipdry warehouse (at
the expense of the customers) if customers are not available.
3 Affer the unit has been rereived by Unipdry (whether at a renair center or the warehouse)
Unipdry will have an initial inspection. If it is determined to be invalid warranty claim (see
exclusions below), customers have to pay for all associated repair costs and shipping costs for
units repair.
4.Customers can pick up the unit after repair at their own expense for shipping. Units will
have a rigorous testing before sending it back to customers.
5. If the unit can no longer be fixed, and it is in the warranty period and determined to be valid
claim, we will ship the customer a new unit within the same year warranty from the date of
replacement.
6. After parts are repaired or replaced by Unipdry, the original warranty period continues
to applies until meet its deadline. No extensions to the original warranty period.
5 6
Uni-P Vantix 950 AIR MOVERS Installation, Operation & Service Instructions Uni-P Vantix 950 AIR MOVERS Installation, Operation & Service Instructions

Tel: 888-994-0895 Tel: 888-994-0895
Warranty Exclusions:
DAMAGE DUE TO THE FOLLOWING IS NOT covered under warranty
1.Acts of Nature- including but not limited to:
flooding
fire
water damage
hurricane/storm damage
2. IMPROPER USAGE- Including but not limited to:
misuse, abuse, or tampering whether intentional or accidental
improper installation or design
Improper voltage
lack of normal care
failure to follow instructions
3. Corrosion
4.Freezing
5.Any additional costs due to changes in laws or building codes
6.Freight charges
7.Any costs due to lost profit or delay
8.Damage to property
9.Cause beyond control
10.Consumable parts, including but not limited to
filters
batteries
power cords
valves
switches
rubber parts
11. Direct, indiret, collateral or inconsequential damages of any kind
THE WARRANTIES AND LIABILITIES SET FORTH ARE IN LIEU OF ALL OTHER
WARRANTIES EXPRESSED OR IMPLIED, IN LAW OR IN FACT, INCLUDING IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR
PURPOSE.Unipdry's total li- ability, regardless of nature of claim shall not exceed original
purchase price of the product. If a product or component is replaced while under warranty,
the applicable warranty period shall not be extended beyond the original warranty
time period.
The foregoing shall constitute the total liability of seller in the case of defective
performance of all or any of the equipment or services provided to Buyer, Buyer aarees to accept
and hereby accepts the foregoing as the sole and exclusive remedy for any breach or alleged
breach of warranty by Seller
Any dishonesty or fraud in connection with Unipdry warranty thorouahly voids all
warranty policies.Unipdry expressly reserves the right to pursue legal action in the event of
dishonesty, fraud. or attempted fraud.
TRANSFORMER
L--IN
Black
Black
Black
Black
Black
Black
PCB
Brown
12 AMP
CIRCUIT
BREAKER
Green
POWR
White
White
White
White
White
WHITE
HOT
LINE
GFCI
LOAD
GND
GND
FAN MOTOR
16 UF
N
NL
L-OUT
LINE
LODE
Green
Wiring Diagram
110-120V/60Hz
7 8
Uni-P Vantix 950 AIR MOVERS Installation, Operation & Service Instructions Uni-P Vantix 950 AIR MOVERS Installation, Operation & Service Instructions
Table of contents
Other Uni-P Dry Fan manuals
Popular Fan manuals by other brands

Vortice
Vortice VORT HA Instruction booklet

Lasko
Lasko 2002C instructions

SHE
SHE SHE39TU2001 manual

Nordic Home
Nordic Home FT-561 user manual

DYNABREEZE
DYNABREEZE FA-23181 Instruction User Manual & Warranty

Vectaire
Vectaire WHHR100/90DC-B Plus Installation, Operating and Maintenance Instructions for the Installer and the User