Unitrol TROLL 3100 User manual

1
DO NOT START THE MACHINE BEFORE READING CAREFULLY THESE
INSTRUCTIONS
REMARK :
Wheel balancing machine TROLL 3100 isn”t equiped an automatic ultrasonic system measurement
geometrical parameters of balanced wheel. All description concern the service this system, placed
in present manual instruction, arent conforming to this type machine.
The balancing machine TROLL 3105 is provided with an automatic measurement system geometric
for measuring parameters of the wheel balanced, start while closing the wheel guard. After closing
the guard the measuring cycle is started automaticaly.
1 . APPLICATION AND TECHNICAL DATA
TROLL 3100 / 3105 balancing machine is designed for dynamic balancing of car and van wheels
in a single measurement cycle.
TECHNICAL DATA :
- max. wheel diameter 1,15 m
- wheel diameter 10” - 24”
- wheel width 2" - 10"
- accuracy of unbalance indications 1 g
- accuracy of unbalance location signal 3 stages
- measurement time 3 s
- machine weight ok. 145 kg
- overall diamensions with closed shield: 1140x900x1150 mm
with open shield : 1140x1050x1450 mm
- whell weight do 60 kg
- drive motor rating 0,25 kW
- spindle spind ( during measurement ) 230 r.p.m.
- power supply 220 V / 50 Hz
- air supply 0,6-1,0 MPa
The balancing machine TROLL 3100/3105 is equipped with a speach synthetiser, emitting
confirmations of each operation performed and suggesting procedures for whel balancing.
Indications quantity and position unbalance take reading on monitor measurement.
Programme „hiden weight” allows on the partition and the spacing of balancing slugs
on invisible spoken of alloy rim. Balancer is equiped an automatic stop at the top which
is blocking of wheel for both point of unbalancing. The brake release is seting after a
little displacement (ca. 3 grades) of wheel from shown unbalancing points or after press
the button on the keyboard which indicate a disapperation of arrows.
2 . INSTALLATION
TROLL - 3100 / 3105 balancing machine should be installed in a closed, dry room, heated during
auttumn / winter season. The machine should be installed on a hard and levelled floor. The balancing
machine should be installed on three rubber pads, suppiled with the machine (item 28, fig. 2)
which should be inserted under the three flat feet welded to the machine base.

2
19 17 20
18
14 15 13
16
10
11
15
16
231
45
67
12
17
18
13
Buttons numbers
25
23
24 21
26
22

3
3. CONTROL PANEL DESCRIPTION (figs 1 and 2)
Announcements emitted by the balancing machine after depressing a particular
push - button are given in barckets
1- Wheel width setting push - button [WIDTH]
2- Wheel diameter setting push - button [ DIAMETER]
3- push - button for setting distance from wheel inside correction plane [ DISTANCE]
4- Key for selection of programme for different weight fixing methods [WHEEL TYPE CHANGE]
5- Lock out threshold selection key [THRESHOLD CHANGE]
6- Machine drive off key
7- Machine drive on key [CAUTION START]
8- Reset push - button [ NEW MEASUREMENT]
9- Key for inititing current unbalance value recording [UNBALANCE CONVERSION]
10- Printer start key
11- Auxiliary key
12- Balancing machine memory initiating key [ MEMEORY READOUT]
13- Subrotine input key
14- Subrotine output key
15- Parameter change key - increase
16- Parameter change key - decrease
17- Cursor up key
18- Cursor down key
19- Cursor left key
20- Cursor right key
21- Balancing machine master switch
22- Printer
23- Socket to connect cabel - lenght shield
24- Sensor run - out measurement in programme minimisation
25- Rubber pad
26- Controller for setting distance of inboard wheel correction plane
Full list announcements emitted by the balancing machine
- SYSTEM TEST - UNBALANCE CONVERSION
- SYSTEM OPERATIVE - CLOSE SHIELD
- ATTENTION START- ACCELERATION ERROR
- THRESHOLD CHANGE - BRAKING ERROR
- CHANGE OF WHEEL RIM TYPE - WIDTH
- CALIBRATION - DISTANCE
- WRONG CALIBRATION - DIAMETER
- WHEEL BALANCED - REDUCE WEIGHT
- WHEEL UNBALANCED - INCREASE WEIGHT
- MEMORY READOUT - SHIFT LEFT
- NEW MEASUREMENT - SHIFT RIGHT

4
4. FITTING BALANCING MACHINE FIXTURE
Before mounting the fixture clean thoroughly with a clth taper surfaces of spindle”1” and fixture
„2”. Install fixture so that markers”3” on spindle dowel and fixture are in the position shown in
fig.
NOTE:
Thorough cleaning of taper surfaces and apprioprate position of fixture in relation to spindle (
markers coinciding)
is one of preconditions of correct wheel balancing.
Rys.2. Fitting fixture without nit, tapers and sleeves

5
5. MOUNTING WHEEL SHIELD
fig. .3. 1- BALANCING 5- MOUNTING BOLTS
2-WHEEL SHIELD 6- SHIELD CABLE
3- SHIELD EYE 7- SOCKET CABLE SHIELD
4- SHIELD PIVOT FLANGE
Set shield (item 2) vertically and fix to shield pivot flange ( item 4) by means of four M8 bolts
(item5 ) passing through shield eye (item 3 ).
Connect guard cable ( item 6) to socket (item7). The connected cable must not be strained
while opening and closingthe guard, it must be slack.
Unless the cable is connected , the automatic start of the balancing machine will not possible.
NOTE :
In the machanism of the shiekd a dramper is provided to limit the opening and closing speed.

6
Rys.4. Zespó³ czujnika bicia
1- statyw czujnika 4- przewód elektryczny
2- czujnik 5- gniazdo czujnika
3- koñcówka statywu czujnika
- STOP
6. MOUNTING SENSOR STAND
In order to mount the run - out sensor the following should be done:
- mount the sensor stand „1” in the guide opening ( in the housing front panel),
- push the sensor „2” in the end part of the stand „3”
- connect the cable plug „4” with the socket”5” a screw down,
The sensor may be mounted on the stand perpendicularly against the balancing machines side
panel ( for the radial run - out measuremant) or parallel against the balancing machines side ( for
the axial run - out measurement).
The cabel „4” is located in the housing ”s rear panel. The ultrasonic generator is located in the
opening in the sensor is front panel.
NOTE :
The sensor is front panel must be turned towards the part being measured.
In case the sensor is not used, the stand should be positioned so that it could not hinder the wheel
balancing .

7
7. CONNECTING - UP THE MACHINE TO POWER SUPPLY
7.1 Installation power supply balancing machine
The balancing machine is provided with a three - condictor power cable.
The conductor with YELLOW - GREEN insulation, connected to the balancing machine housing is
a PROTECTIVE conductor.
7.1.1 Connecting of iar supply
The air pipe ended of slide valve connect to pneumatic adaptor (no 8 pic 3) on the back wall of
balancer
7.2. Installation and connection of monitor
Particular description in monitor instruction.
7.3. Test start of balancing machine
In order to check for correct electrical connection of the balancing machine, perform steps described
in item 7.1. and then depress „START” key.
A CHILED BALANCING MACHINE MAST NOT BE CONNECTED TO THE MAINS BEFORE TWO
OR THREE HOURS, NECESSARY FOR DRYING ELECTRONIC COMPONENTS AND TO REACH
ROOM TEMPERATURE. FAILURE TO DO DO MAY CAUSE SERIOUS DAMAGE TO THE
BALANCING MACHINE.
8. OPERATING BALANCING MACHINE COMPUTER
8.1. Switch balancing machine computer
Switch machine master switch on, as well as monitor power supply switch. Balancing machine
will emit announcement [SYSTEM TEST] and them [ SYSTEM OPERATIVE]. Atest pattern shall
appear on monitor screen and then an advertisingimage. After depressing any key of the
keyboard (fig 1) the computer will be set in [UNBALANCE MEASUREMENT] subroutine and the
image shown in (fig 6) will appear on the monitor screen.
NOTE:
If during the inspection test, key (item.14 fig.1),is depressed,system test will be interrupted
and advertising image display procedure will be interrupted. The computrer will be immediately
set in [UNBALANCE MEASUREMENT] subroutine.
8.2. Select measurement procedure
After depressing the key computer is set in SELECT PROCEDURE programme and image,

8
shown in Fig 5 will appear on the screen.
Entry into respective subroutine is effected by depressing keys.Input to respective subroutine is
effected by guiding the cursor to an appropriate position (box with appropriate subroutine) and
depressing the key . Cursor guiding - by depressing keys .
Output from respective subroutine - by depressing the key .
SELECT PROCEDURE will appear on the screen, shown in Fig. 5
8.3. Unbalance measurement
Cursor guiding by depressing keys an position UNBALABCE MEASUREMENT
(Fig.5) and push button . The computer will set in the subprogramme UNBALANCE
MEASUREMENT, the monitor will show the screen as per figure .6.
After this subprogramme has been initiated , the cursor will always point item 5 ( Q - cut - off
threshold).
Fig.5

9
Guide cursor to position 10 (fig.6) with keys 17, 18, 19, 20 (fig.1). It is choice between automatic
and manual start.
- AUTOMATIC START - by means of keys or setting iconrepresenting pictogram
D))))) . Balancing machine comuter will be then programmed for automatic start. In this case,
parameters of the wheel, mounted in the chuck, will be entered in machine memory during
wheel guard closure and after closing the guard the machine will start automatically, measure
unbalance value, stop the wheel and display measurement results.
- MANUAL START- by means of keys or setting in position 10. Balancing machine
computer will br then programmed for manual start. In this case, parameters of the wheel to be
balanced are entered to machine memeory, as described in items 8.3.1. - 8.3.3.
Above is concerning balancer TROLL 3105 Automatic start in balancer TROLL 3100 is setting
other way. The change of mode starting will be realized by simultaneous pressing the button
and button . If will show inscription AUT in position „10” (fig 6). The automatic
starting will be connected after a closing of guard. If the inscription AUT isn”t shown. It means that
machine is programming in manual start. The engine is connecting after pressing the button
.
Fig 6
item 1
item 2
item 3
item 4
item 5
item 6
item 7
item 8
item 10

10
8.3.1. Entering DISTANCE parameter manualy.
Guide cursor to position.1 (fig.6) over depressing key or keys 17, 18, 19, 20 (fig.1). The
machine will emit [DISTANCE] announcement.
Wheel distance setting should be dtermined as follows:
a) after the positioner has been moved to the rim edge and than back to the start position a
number will be shown which is in a proportion to the positioner move (see fig. 7a)
NOTE:
The positioner must not be in the protruded position during the balancing machine switch - on
and the computer reset. Otherwise the distance measurements will be false as the computer
reads the positioner is position during switch - on as the zero position.
b) in case the distance should be entered without using the positioner the following should be
done:
(look fig.7 b)
- measure with a rule distance L between balancing machine wall and the rim of the wheel
mounted in wheel chuck (measurement in centimetre)s
- multiply the measured value by four and subtract three, according to formula:
DISTANCE = (4 x L) - 3
8.3.2. Entering „DIAMETER” parameter manually.
Guide cursor to position 2 (fig..6)over depressing key or by means of arrow 17 - 20. The
machine will emit [DIAMETER] announcement.
Depressing keys or the value of this parameter is from 10 to 24 inches.
8.3.3. Entering „WIDTH” parameter manually.
Guide cursor to position „3” (fig 6) or by means of arrow 17 - 20. The machine will emit
[WIDTH] announcement. Depressing keys or the value of this parameter is from 2
to 10 inches
8.3.4. Balancing Programm Selection (irrespective of start) Guide cursor to position 4
(fig.6) over depressing key or by means arrow 17 - 20. The balancing machine will emit
[ WHEEL TYPE CHANGE]
By depressing key or it choice of the variant of balancing slug accordingly to the
wheel rim type.

11
Fig7b . L - DISTANCE
Fig 7 a

12
alternative 1
balancing through tapping weights
on both wheel rim edges
alternative 2:
balancing trough sticking weights
alternative 3:
balancing trough tappingone weight on
the inside balancing plane and sticking
another on the inner wheel rim edge
alternative 4:
balancing trough sticking one weight
on the inside balancing plane and
tapping another on the outer wheel rim
edge
alternative 5:
static balancing ( for very thin wheel rims,
with one weight). Not recommended for car
wheels
alternative 6:
balancing trough sticking weights
inside wheel rim
alternative 7:
balancing through tapping one
weights on inside correction
plane and sticking another inside
wheel rim

13
Return to previous measurement pattern is effected by guiding the cursor to item 6 and push -
button .
Fig.8.
8.3.6. Voice Volume Adjustment
Guide cursor by means of arrow to position 8 (fig.6). Over push button or we change
voice volume adjustment.
8.3.7. Change of Measurement Pattern
Guide cursor by means of arrows to position 7 (fig.6) and push - button .
Measurement pattern, shown in Fig 8 will be displayed on monitor screen.
8.3.5. Entering Cut - Off Threshold Value
Guide cursor to position 5 (fig.6) over push - button or by means of arrow. The balancing
machine will emit [ THRESHOLD CHANGE ].
Push- button or cut - off is changed 0g, 2g, 5g or 10g threshold may be set.
NOTE:
Entering cut - off threshold value”0” is changed automatic on value „2” after starting balancing
machine.

14
8.4. Setting Edit
Enter SELECT PROCEDURE subroutine by pressing key .
Guide cursor keys to position SETTING EDIT (Fig.5).
Push - button . The computer will be set in SETTING EDIT suroutine and image shown in
Fig 9 will be displayed on monitor screen.
Fig.9.
Computer has the capability of recording and storing parameters of eight different, most
frequently balanced, wheels.
8.4.1. Recording parameters in memory
Guide cursor keys to position where data of a particular wheel are to be recorded.
Example: recording wheel data of VOLVO car in position 1 (Fig.9):
Push - button . Computer will be set in DETERMINE SETTING VALUES subroutine and
image shown in Fig 10 will appear on the screen.
item 1
item 2
item 3
item 4
item 5
item 6
item 7
item 8

15
Fig.10.
Guide cursor keys to position 1 (Fig.10), with keys , and then set cursor
in box first from the left. Push - buttons so as to have letter P appear in this box. By
means key enter subsequent box and key so as to have letter O appear. Following
this procedure complete the word VOLVO.
Guide cursor keys to position 2 and by means of keys determine
DISTANCE value appropriate for the particular wheel type.
In silimar manner, programme WHEEL DIAMETER in pos.3, WHEEL WIDTH in pos.4, WHEEL
TYPE in pos.5 and MEASUREMENT ACCURACY in pos.6.
By pushing button this data are entered to computer memory what is conform by
announcement MEMORY RECORDING. On monitor screen image shown in Fig 9 will appear
with name VOLVO.
8.5. Heading Edit
Input to PROCEDURE SELECT subroutine by pushing button .
Guide cursor with keys to position HEADING EDIT (Fig rys.5)and push button
. The computer will be set up in HEADING EDIT position and image shown in Fig.11 will
be displayed on monitor screen.
item 1
item 2
item 3
item 4
item 5
item 6
item 7

16
8.5.1. Recording heading edit
Buttons guide cursor to position from 1 to 4 (Fig.11).
Buttons guide cursor on box to position from 1 to 4.
Buttons choice box and setting any letter or figure.
In positions from 1 to 4 enter name of the works (name, adress, phone).
After settingin each position, store them in memory by pushing button . Output from
respective subroutine by pushing button .
8.5.2. Setting time
Push button guide cursor to position 5a (Fig.11).
Buttons set hour
Push button guide cursor to position 5b.
Buttons set minutes.
8.5.3. Setting data
Setting data is similar to setting time
Set date in c - month in d - year in e.
item 1
item 2
item 3
item 4
item 5
a
bcde
Fig 11

17
NOTE:
After setting data in each position , store them in memory by pushing button .
8.6. Measurement counter
Enter SELECT PROCEDURE subroutine by pushing button . Guide cursor with keys
to position MEASUREMENT COUNTER and press . The computer will be set in
MEASUREMENT COUNTER subroutine and image, shown in Fig.12 will appear on monitor
screen.
Fig.12.

18
9. WHEEL BALANCING INSTRUCTIONS
9.1. Mounting The wheel On The Balancing Machine
Wheels with a central hole are mounted is a central fixture, supplied as standard equipment
withthe balancing machine. This fixture is to be fitted to the balancing machine spindle as
decsribed in item 4 below.
NOTE: It is recommended to wash the wheel prior to mounting on the balancing machine to
prevent distortion of measurement by mud particles.
9.1.1 Quick release fixture
Type QUICK - TROL quick release fixture is intended for mounting car on a van wheels, with
central hole wheel rims, on balancing machines
FIXTURE COMPONENT PARTS ( Fig.13):
1 -Hub
2 -Bolt for mounting fixture to balancing machine spindle
3 -Spring
4 -Clamping nut
5 -Centering taper No.1
6 -Centering taper No.2
7 -Pressure ring
8 -Centering disc No.1 (with twin taper)** ( 120 - 140 mm)
9 -Centering disc No.2 (with twin taper)** ( 140 - 160 mm)
** extra equipment
1
2
3
4
5
6
8
9
7
1

19
CLAMPING NUT (Fig 14)
Clamping nut lever moves in relation to nut body within limits detrmined by slot in nut body
(positions L and D). In position L (loose), the nut may be freely moved along fixture rod
thread. In position D (clamp), the nut may be screwed onto fixture rod thread.

20
MOUNTING WHEEL IN FIXTURE
Slide wheel on fixture bolt and suspend it by the edge of central hole centering taper detent.
Set nut lever in position RELEASE and push nut against wheel, as far as it will go. Resting
thumb on nut pin (as shown in Fig.15) move lever to the right, to position CLAMP and tighten
nut, preesing the whell against fixture disc.
Fig..15. Tightening nut
in order to remove wheel from fixture, rest index finger on nut pin (as shown in Fig. 16) and
loosen nut by one half turn. It may be then slid off the rod and the wheel may be removed from
fixture.
Fig. 16 Loosening nut
This manual suits for next models
1
Table of contents
Other Unitrol Wheel Balancer manuals
Popular Wheel Balancer manuals by other brands

Coats
Coats Vero Series Safety, Setup, Operation & Maintenance Manual

WilTec
WilTec XPOtool 51742 Operation manual

CEMB
CEMB EZ15 installation manual

Atlas
Atlas PWB 50 Use and maintenance instruction manual

ATEK MAKINA
ATEK MAKINA KONIG NEWLINE Series Instruction booklet

Endo
Endo HKS15N900-20 instruction manual