Unoisetion MS-76D1 User manual


- 2 -
Warning
Dear users:
Thanks for choosing our company’s product, in order to fully make use of the products, we
sincerely suggest follow:
◆◆Please read the instruction in detail and keep it well for further reading and consulting.
◆◆Please follow the instruction to fit and operate the machine correctly.
◆◆Please do not remove and change any accessories of the machine.
◆◆It forbids others others to open and remove the mainframe except the authorized people
in the company.
◆◆It forbids others to change and maintain the machine except the professional people.
◆◆Please contact us if there is any trouble during operation.
After Sale service
◆We offer ONE YEAR warranty. Within warranty period, all exchanges or replacement due to
defects are free. (Buyer is responsible for shipping charges).
If the machine is over warranty, please also do not hesitate to contact us. we will assure you of
our best service all the time.
◆How to contact us?
Phone:(+86) 189 -487-55929
Tel: 0755-86368500
Email: sales@mychway.com
This product does not belong to medical,please don’t use for disease treatment!

- 3 -
Warning
Dear users:
Thanks for choosing our company’s product, in order to fully make use of the products, we
sincerely suggest follow:
◆◆Please read the instruction in detail and keep it well for further reading and consulting.
◆◆Please follow the instruction to fit and operate the machine correctly.
◆◆Please do not remove and change any accessories of the machine.
◆◆It forbids others others to open and remove the mainframe except the authorized people in
the company.
◆◆It forbids others to change and maintain the machine except the professional people.
◆◆Please contact us if there is any trouble during operation.
After Sale service
◆We offer ONE YEAR warranty. Within warranty period, all exchanges or replacement due to
defects are free. (Buyer is responsible for shipping charges).
If the machine is over warranty, please also do not hesitate to contact us. we will assure you of
our best service all the time.
◆How to contact us?
Phone:(+86) 189 -487-55929
Tel: 0755-86368500
Email: sales@mychway.com
This product does not belong to medical,please don’t use for disease treatment!

- 4 -
Table of Contents:
1. Introduction to Manual .............................................................................................................
1.1 Purpose .......................................................................................................................
1.2 Conventions ................................................................................................................
2. Medical Safety............................................................................................................................
2.1. Indications for Use.......................................................................................................
2.2. Contraindications .........................................................................................................
2.3. Precautions ..................................................................................................................
2.4. Patient Safety................................................................................................................
3. Features&Function........................................................................................................................
3.1. Features.........................................................................................................................
3.2. Function.........................................................................................................................
4. Control Unit & Handpiece............................................................................................................
5. Operation Procedures..................................................................................................................
5.1. Cavitation 40k probe.......................................................................................................
5.2. Vacuum Bipolar RF Handle ............................................................................................
5.3. Multipolar RF Head for Body..........................................................................................
5.4. Quadrupole RF Head for Face and Body.........................................................................
5.5. Three pole RF Head for Face and Eyes' Around.............................................................
5.6. Cold probe......................................................................................................................
5.7. Photon& Micro Current for Skin care ............................................................................
6. Package Including...... ....................................................................................................................
7. Notice............................................................................................................................................
8. Illustration of Operation................................................................................................................

- 5 -
1. Introduction to Manual
1.1 Purpose
This instructions for use manual provides a description of the system components, its
controls and displays, instructions for its operation, and other equipment information
important to the user
Warning: Do Not operate this machine before reading this manual thoroughly. In
addition to this manual,additional clinical training may be available by the company
or your local distributor.
For more information on training available please contact your local representative.
1.2 Conventions
Note: Notes designate information of special interest.
Caution: Cautions alert the user to precautionary steps necessary to properly
operate the system.Failure to observe these cautions may void the warranty
Warning: Warnings alert the user to information that is of the highest importance
and vital to the safety of the patient and user
All procedures are broken down by numbered steps.Steps must be completed in the sequence
they are presented
Bulleted lists indicate general information about a particular function or procedure.They do not
imply a sequential procedure.
Control names are spelled as they are on the system,and they appear in Bold text
2. Medical Safety
2.1. Indications for Use
The cavitation vacuum RF micro current photon machine is indicated for use as a
non-invasive dermatological aesthetic treatment to:
Body slimming,body sculpture

- 6 -
Face care,lifting,whitening
Neck skin lift
2.2. Contraindications
The cavitation vacuum RF micro current photon machine is contraindicated for use in
patients with:
Open wounds or lesions on the face and/or neck
Severe or cystic acne on the face and/or neck
2.3. Precautions
The cavitation vacuum RF micro current photon machine has not been evaluated for
use over various materials. Therefore, treatment is not recommended directly over
those areas with any of the following:
Mechanical implants
Dermal fillers
Implanted electrical devices in the face and/or neck
Metal stents in the face and/or neck area
Treatment energy is not recommended for use directly on an existing keloid.
The cavitation vacuum RF micro current photon machine has not been evaluated for use
in patients on an anticoagulant treatment plan
It is recommended that the following areas should be avoided during treatment:
Thyroid gland, thyroid cartilage and trachea
Major vessels
The cavitation vacuum RF micro current photon machine has not been evaluated for use
in the following patient populations:
Pregnant or breast feeding women
Children
Those with the following disease states
A hemorrhagic disorder or hemostatic dysfunction
An active systemic or local skin disease that may alter wound healing
Herpes simplex
Autoimmune disease
Diabetes
Bell’s palsy

- 7 -
2.4. Patient Safety
Warning: cavitation vacuum RF micro current photon machine should not be
used on a patent’s eyes or in a location or technique where ultrasound energy
can reach the eye.
Warning: Use this system only if you are trained and qualified to do so.
Warning: If any problems occur during system operation, ask immediate
action(s): lift the transducer off the patent’s skin, press the STOP button to
completely halt system operation.
3. Features&Function
3.1 Features
Painless treatment focus RF energy at the correct position, compared to other
radio frequency technology. It uses low energy and high frequency,safe and
effective.
Aim at the skin surface and deep location, using a complex method to control the
different currents and energy, direct access to the different skin layer. Does not
cause the phenomenon of uneven skin.
Selectively targeting fatty tissue, to avoid heating other fat, to achieve the fastest
treatment effect.
The entire process is completed without the need of surgery and anesthesia.
With the most useful 40KHZ ultrasonic cavitation system.
Without side effects and the risk of gaining the weight back, the results are rather
obvious. Does not affect the normal work and life.

- 8 -
3.2 Functions
Firming the arms, legs, thighs, buttocks, waist, back, abdominal muscles and reshape
the body figure Improve and treat the orange peel like fatty tissues of different
serious levels With the effects of soothing, decompression and pain relief (such as
joint pain, sciatica), promote the regular mechanical aerobic exercise of skin tissue,
rapidly relieve stress and remove fatigue. Firming, lifting and compact the skin and
mould the face shape circulate and activate cells, promote metabolism and so that
100% more collagen and elastic fibers may be gained for improving the facial and
body skin.
4. Control Unit & Handpiece
5. Operation Procedures:
5.1 Cavitation 40k Probe

- 9 -
Press and to adjust the working time.
Press to decrease the energy, and press to increase the energy. Level 1~9
can be adjusted.
Press to select the model. Two models A,B can be selected.
Model A:continuous wave, for the area with thin fat;
Model B:dis-continuous wave, for the area with thick fat.
Press to start or pause the operation.
Operate with the 40KHz cavitation head for 15-20 minutes.
Warming:
Cavitation 40k Probe is forbidden to treat on back
5.2 Vacuum Bipolar RF Handle
Press and to adjust the working time.
Press to decrease the energy, and press to increase the energy. Level
1~9 can be adjusted.
Press to select the model. Two models A,B can be selected.

- 10 -
Press to adjust the suction time; Press to adjust the
release time(adjust according to the customer's acceptable level, 3-6 is ok).It is better
for the suction time longer than the release time.
Press to start or pause the operation.
Warm tips:
Apply enough slimming cream/gel on the treatment area.
Keep in full contact with the skin during treatment, move the probe on the surface of
the cared area, in an even and thorough way
Adjust the intensity from low level to high level.
Please close eyes during led photon therapy, direct aim to eyes is forbidden
15-20 minutes on each treatment area recommended
5.3 Multipolar RF Head for Body
Press and to adjust the working time.
Press to decrease the energy, and press to increase the energy. Level
1~9 can be adjusted.
Press to select the model. Two models A,B can be selected.
Press to start or pause the operation.
Warm tips:
Keep in full contact with the skin during treatment, move the probe on the surface
of the cared area, in an even and thorough way

- 11 -
Adjust the intensity from low level to high level.
Please close eyes during led photon therapy, direct aim to eyes is forbidden
15-20 minutes on each treatment area recommended
5.4 Quadrupole RF Head for Face and Body
Press and to adjust the working time.
Press to decrease the energy, and press to increase the energy.
Press to select the model. Two models A,B can be selected.
Press to start or pause the operation.
Warm tips:
Apply enough slimming cream/gel on the treatment area.
Keep in full contact with the skin during treatment, move the probe on the surface of
the cared area, in an even and thorough way
Adjust the intensity from low level to high level.
Please close eyes during led photon therapy, direct aim to eyes is forbidden
15-20 minutes on each treatment area recommended
5.5 Three pole RF Head for Face and Eyes' Around

- 12 -
Press and to adjust the working time.
Press to decrease the energy, and press to increase the energy.
Press to select the model. Two models A,B can be selected.
Press to start or pause the operation.
5.6 Cold probe (calming down the skin and shrinking pores)
The temperature of skin will up after the treatment of the cavitation probe, vacuum
probe and RF probes. Then use the the cold probe, it helps to calm down the skin, and
shrink pores.
Press the red on/off button of the probe to start/pause the probe,working time 5-10
minutes.

- 13 -
5.7 Photon& Micro Current for Skin care
Press and to adjust the working time.
Press to decrease the energy, and press to increase the energy.
Press to select the model. Two models A,B can be selected.
Press to start or pause the operation.
Curative Effect:
Red: Vitalize be suitable for any skin, promote blood circulation, and regenarate collagen
protein in order to smooth skin and heal xerodermia, exuviation, degenerate losing
hair and folliculosis.
Blue: Calm be suitable for sensitive, oil, and comedo skin-diminish and eliminate acne
bacilus to remove acne, whelk, promote to compound protein with ossein,activate
skin, tighten slack skin and gravidity winkle.
Green: Balance Normalize sebaceous glands ,Reduce black heads and sores, balance
moisture.
Purple: Drain Renew skin, reduce wrinkles
Orange: Brighten whiten decompose pigment, and smooth scares
Turquoise: Defense strengthen the ability to protect skin, calm down, release stress,
White: Guide guide skin to absorb nutrients and anti-aging
6. Package Including
Maichine x 1
Multipolar RF Head for Body x 1
40KHz Unoisetion Cavitation Head x 1
Vacuum Biploar RF Head x1

- 14 -
Three Pole RF Head for Face and Eyes' Around x 1
Quadrupole RF Head for Face and Body
Photon&Micro Current probe x 1
Cold probe x1
Power cord x 1
7. Notice
1. Please insert the vacuum filter on the rear of the machine before switch machine.
Make sure the vacuum filter in the following condition
2. If the vacuum suction is weak, please adjust the adjustment knob:
Clockwise rotation:Min to Max.

- 15 -
8. Illustration of Operation

- 16 -