manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Upgrading everyday security
  6. •
  7. Control Panel
  8. •
  9. Upgrading everyday security iconnect Instruction manual

Upgrading everyday security iconnect Instruction manual

Other manuals for iconnect

1

Other Upgrading everyday security Control Panel manuals

Upgrading everyday security iconnect 2 Instruction manual

Upgrading everyday security

Upgrading everyday security iconnect 2 Instruction manual

Popular Control Panel manuals by other brands

GENEVO PRiMA 6 installation manual

GENEVO

GENEVO PRiMA 6 installation manual

NAPCO X 255 - Programming instructions

NAPCO

NAPCO X 255 - Programming instructions

Next Systems UNIR1 230 instruction manual

Next Systems

Next Systems UNIR1 230 instruction manual

HORNER HE-XPW1E0 user manual

HORNER

HORNER HE-XPW1E0 user manual

DSC CLASSIC PC1555 instruction manual

DSC

DSC CLASSIC PC1555 instruction manual

Bosch Solution 2000 installation guide

Bosch

Bosch Solution 2000 installation guide

VRinsight MS Panel user manual

VRinsight

VRinsight MS Panel user manual

Zeiss SYCOP 3 Quick reference guide

Zeiss

Zeiss SYCOP 3 Quick reference guide

HULTSTEINS ECOFRIDGE DISPLAY user manual

HULTSTEINS

HULTSTEINS ECOFRIDGE DISPLAY user manual

Elkron C420 Programming manual

Elkron

Elkron C420 Programming manual

GST GST200-2 Installation and operation manual

GST

GST GST200-2 Installation and operation manual

Efka Variocontrol V810 instruction manual

Efka

Efka Variocontrol V810 instruction manual

RDZ PC-HRX user manual

RDZ

RDZ PC-HRX user manual

STG-BEIKIRCH MZ3 operation instruction

STG-BEIKIRCH

STG-BEIKIRCH MZ3 operation instruction

AMX AutoPatch CP-15 instruction manual

AMX

AMX AutoPatch CP-15 instruction manual

Cebora 208-10 instruction manual

Cebora

Cebora 208-10 instruction manual

Satel CA-6 KLED-S user manual

Satel

Satel CA-6 KLED-S user manual

Evolution IQ plus 800 installation manual

Evolution

Evolution IQ plus 800 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Quick User Guide
2
Thank you for choosing iConnect wireless intruder control panel. This quick start guide
describes the main user operating actions of the iConnect. To view the full version of the
Installer manual, please refer our website www.electronics-line.com
Full Arm
Press
If required, enter
your user code
Partial Arm
Press
Perimeter Arm
Press
Disarm Enter your user code In addition,
silences the siren in
alarm event
Partition 1/2 Arm
Press /
Available in a
partitioned system
Partition 1/2 Disarm
Enter your user code > /
Partition 1+2 Disarm
Enter your user code >
Panic alarm Press and hold down +
Fire alarm Press and hold down +
Medical alarm Press and hold down +
Check system troubles Press and scroll the list Additionally,
silences an error
tone
Global Chime Press
Access Menu Mode Press then User Code]
Ser ice Call
Press and hold
Turn On / Off PGM /  30
3
LEDs Indication
LED:
Off: System disarmed
Green : System armed
Flashing red : Alarm
'OK' LED:
Green: Power OK
Yellow: System trouble
Flashing green: Open zone
Flashing yellow: (Slow) Low
battery, (Fast) AC loss
Edit/Delete User Code
. From the main display press .
2. Enter master code (Default code 234)
3. Select [4] User Code and press
4.Select a user and press
5. Select [ ] Edit Code.
6. Edit the user code or enter 0000 to
delete
7. Press
Bypass / Unbypass a zone
. Go to the main display and press .
2. Insert master code (default code ' 234')
3.On the Main menu, press [2 ]
4. Select a zone and press to toggle
5. To save the status, press
SMS Control Commands
Controlling the System through SMS
Command Code Numbers:
120: Disarm
121: Full arm
122: Part arm/Partition arm
200: System arm status
123: Perimeter arm/Partition 2 arm
128: Disarm partition
129: Disarm partition 2
0XX: HA unit XX off
1XX: HA unit XX on
030: PGM off
130: PGM on
SMS Structure: [Free text - Up to 43 characters][#][User Code][Command]
Example: DISARM# 234 20
4
Telephone Control Commands
1.Dial the number of the premises
If your system is connected to a regular phone line. Dial the number of the panel and
wait for three rings then hang up. Wait at least five seconds and dial the number again.
On the second ring the control system answers and sounds two tones.
If your system support cellular communication dial and wait until the system answers
and two tones are heard.
2.Within 15 seconds enter the Telecontrol Code (code 29). After a tone sounds press:
3: Full arm
6: Disarm
7: Extend the call
9: Cancel siren
2: 2 Way Audio
4XX: HA Unit XX On
5XX: HA Unit XX Off
430: PGM on
530: PGM off
*#: Disconnect the line
Partitioned System
31: Full Arm
32: Arm Part. 1
33: Arm Part. 2
61: Full disarm
62: Disarm Partition 1
63: Disarm Partition 2
Keyfob
: Full Arm
: Disarm
: Part Arm HA/PGM
/ : Perimeter Arm HA/PGM
Partitioned System
: Arm P1
: Arm P2
→: Disarm P1
→: Disarm P2:
→: Disarm P1+P2
Connecting to your Web Browser Application
1. Enter the Web page address supplied by your WEB service provider and press Go.
2. Log In page:
a. User name and Password – Enter values supplied by your WEB service provider.
b. Pass ode – Enter your iConnect user code
3. Click the Enter button
Electronics Line 3000 Ltd. 11/2011 5IN1489 B