Quick User Guide
2
Thank you for choosing iConnect wireless intruder control panel. This quick start guide
describes the main user operating actions of the iConnect. To view the full version of the
Installer manual, please refer our website www.electronics-line.com
Full Arm
Press
If required, enter
your user code
Partial Arm
Press
Perimeter Arm
Press
Disarm Enter your user code In addition,
silences the siren in
alarm event
Partition 1/2 Arm
Press /
Available in a
partitioned system
Partition 1/2 Disarm
Enter your user code > /
Partition 1+2 Disarm
Enter your user code >
Panic alarm Press and hold down +
Fire alarm Press and hold down +
Medical alarm Press and hold down +
Check system troubles Press and scroll the list Additionally,
silences an error
tone
Global Chime Press
Access Menu Mode Press then User Code]
Ser ice Call
Press and hold
Turn On / Off PGM /  30
3
LEDs Indication
LED:
Off: System disarmed
Green : System armed
Flashing red : Alarm
'OK' LED:
Green: Power OK
Yellow: System trouble
Flashing green: Open zone
Flashing yellow: (Slow) Low
battery, (Fast) AC loss
Edit/Delete User Code
. From the main display press .
2. Enter master code (Default code 234)
3. Select [4] User Code and press
4.Select a user and press
5. Select [ ] Edit Code.
6. Edit the user code or enter 0000 to
delete
7. Press
Bypass / Unbypass a zone
. Go to the main display and press .
2. Insert master code (default code ' 234')
3.On the Main menu, press [2 ]
4. Select a zone and press to toggle
5. To save the status, press
SMS Control Commands
Controlling the System through SMS
Command Code Numbers:
120: Disarm
121: Full arm
122: Part arm/Partition arm
200: System arm status
123: Perimeter arm/Partition 2 arm
128: Disarm partition
129: Disarm partition 2
0XX: HA unit XX off
1XX: HA unit XX on
030: PGM off
130: PGM on
SMS Structure: [Free text - Up to 43 characters][#][User Code][Command]
Example: DISARM# 234 20
4
Telephone Control Commands
1.Dial the number of the premises
If your system is connected to a regular phone line. Dial the number of the panel and
wait for three rings then hang up. Wait at least five seconds and dial the number again.
On the second ring the control system answers and sounds two tones.
If your system support cellular communication dial and wait until the system answers
and two tones are heard.
2.Within 15 seconds enter the Telecontrol Code (code 29). After a tone sounds press:
3: Full arm
6: Disarm
7: Extend the call
9: Cancel siren
2: 2 Way Audio
4XX: HA Unit XX On
5XX: HA Unit XX Off
430: PGM on
530: PGM off
*#: Disconnect the line
Partitioned System
31: Full Arm
32: Arm Part. 1
33: Arm Part. 2
61: Full disarm
62: Disarm Partition 1
63: Disarm Partition 2
Keyfob
: Full Arm
: Disarm
: Part Arm HA/PGM
/ : Perimeter Arm HA/PGM
Partitioned System
: Arm P1
: Arm P2
→: Disarm P1
→: Disarm P2:
→: Disarm P1+P2
Connecting to your Web Browser Application
1. Enter the Web page address supplied by your WEB service provider and press Go.
2. Log In page:
a. User name and Password – Enter values supplied by your WEB service provider.
b. Pass ode – Enter your iConnect user code
3. Click the Enter button
Electronics Line 3000 Ltd. 11/2011 5IN1489 B

Other manuals for iconnect

1

Other Upgrading everyday security Control Panel manuals

Upgrading everyday security iconnect 2 Instruction manual

Upgrading everyday security

Upgrading everyday security iconnect 2 Instruction manual

Popular Control Panel manuals by other brands

Bosch B5512 reference guide

Bosch

Bosch B5512 reference guide

Mitsubishi GT2715XTBA installation manual

Mitsubishi

Mitsubishi GT2715XTBA installation manual

resideo PROHP-EU quick guide

resideo

resideo PROHP-EU quick guide

Alarm Lock Eagle 8000 Series operating guide

Alarm Lock

Alarm Lock Eagle 8000 Series operating guide

Prestel MFCP-6 user manual

Prestel

Prestel MFCP-6 user manual

Pepperl+Fuchs VisuNet FLX RM-320P Series manual

Pepperl+Fuchs

Pepperl+Fuchs VisuNet FLX RM-320P Series manual

Cooper Menvier Scantronic 9751 Installation and programming guide

Cooper Menvier

Cooper Menvier Scantronic 9751 Installation and programming guide

Renkforce 1713218 operating instructions

Renkforce

Renkforce 1713218 operating instructions

SJE Rhombus 122 Installation and operation manual

SJE Rhombus

SJE Rhombus 122 Installation and operation manual

Truma CP plus VarioHeat operating instructions

Truma

Truma CP plus VarioHeat operating instructions

Bosch Rexroth IndraControl VDP 08.3 manual

Bosch

Bosch Rexroth IndraControl VDP 08.3 manual

Schaudt LT 100 operating instructions

Schaudt

Schaudt LT 100 operating instructions

Potter PFC-3005T Installation and operation manual

Potter

Potter PFC-3005T Installation and operation manual

eKey home series operating instructions

eKey

eKey home series operating instructions

AERMEC PXL 2 E manual

AERMEC

AERMEC PXL 2 E manual

Honeywell NOTIFIER INSPIRE E10 operating instructions

Honeywell

Honeywell NOTIFIER INSPIRE E10 operating instructions

SJE Rhombus Three Phase Duplex Installation and operation manual

SJE Rhombus

SJE Rhombus Three Phase Duplex Installation and operation manual

ESAB Caddy TA33 instruction manual

ESAB

ESAB Caddy TA33 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.