URC Total Control MRX-12 User manual

MRX-12
Owner’s Manual
Total Control MRX-12
Owner’s Manual

Total Control MRX-12
Owner’s Manual
Rev 1.1
Technical Suppor t
Toll Free: 800-904-0800
Main: 914-835-4484
techsupport@urc-automation.com
H o u r s : 9 : 0 0 a m - 5 : 0 0 p m E S T M - F
Table of Contents
Introduction ........................................................................................................................................................................................................................................................................1
Front Panel Descriptions .................................................................................................................................................................................................................................................2
Rear Panel Description ....................................................................................................................................................................................................................................................3
Installing the MRX 12 .......................................................................................................................................................................................................................................................4
Network Installation..................................................................................................................................................................................................................................................4
Connecting IR Emitters..............................................................................................................................................................................................................................................5
Connecting RS 232 (serial): ......................................................................................................................................................................................................................................6
Specifications ....................................................................................................................................................................................................................................................................7
Limited Warranty Statement............................................................................................................................................................................................................................................7

1
Total Control MRX-12
Owner’s Manual
Introduction
The MRX-12 Advanced Network System Controller controls is designed to meet the
needs of large residential or small commercial environments.
nly Total Control software, products, and user interfaces are supported by this
powerful device.
This device is not compatible with Total Control 1.0 legacy products.
Features and Benefits
• Stores and issues commands for all IP, IR, RS-232, Relays, Sensors, and 12V
Triggers controlled devices.
• Provides two way communication with Total Control user interfaces.
(remotes and keypads).
• Easy rack-mounting via the included rack mounting ears.
Parts List
The MRX-12 Advanced Network Controller includes:
• 1x MRX-12 Advanced Network
System Controller
• 1x AC Power Adapter
• 1x Power Cord
• 1x Adjustment Tool
• 6x IR Emitters 3.5mm (Standard)
• 2x Rack Ears

2
Total Control MRX-12
Owner’s Manual
Front Panel Descriptions
The front panel consist of two (2) indicator lights that illuminate during usage:
1. Power: Indicates that the MRX-12 is powered when illuminated.
2. Ethernet: When the device has a valid Ethernet connection the indicator
light remains a solid blue.

3
Total Control MRX-12
Owner’s Manual
Rear Panel Description
Below are the rear panel ports:
1. Power: Attach the included power supply here.
2. USB: For future expansion.
3. LAN: RJ45 10/100/1000 Ethernet port.
4. IR Outputs: Six (6) standard 3.5mm IR emitter ports with two output
level adjustment screws for outputs ve (5) and six (6).
5. Relay: Single programmable relay at N , NC, or C M.
6. 12V Out: Single programmable output. May be programmed to turn on,
off, or momentarily toggle.
7. Sensors: Two (2) sensor ports that allow the programming of state
dependent and triggered macros. Compatible with all URC sensors.
8. RS232: Two (2) RS-232 ports. Supports TX, RX, and GND connections for
wired two-way communication.
USB
Power LAN Relay Sensors
RS 232
12V/0.2A Out
IR Outputs

4
Total Control MRX-12
Owner’s Manual
Installing the MRX 12
The MRX-12 Advanced Network System Controller can be installed almost anywhere in
the home.
nce physically installed, it requires programming by a certified URC integrator in
order to operate local equipment using IP (network), RS-232 (serial), IR (infrared), or
relays. All cables must be connected to their respective ports at the rear of the device.
Network Installation
1. Connect an Ethernet cable (RJ45) to the rear of the MRX-12 and the onto
an available LAN port of the network’s local router (Luxul preferred).
2. A certied URC integrator is required for this step, congure the MRX-12
to a DHCP/MAC reservation within the local router.
1
2

5
Total Control MRX-12
Owner’s Manual
Connecting IR Emitters
IR emitters are used to communicate to AV devices such as cable boxes, televisions,
blu-ray players and more.
1. Plug IR Emitters (six (6) supplied in the box)into any of the six (6) IR outputs
available on the rear of the MRX-12.
IR utput 5and 6include an adjustable sensitivity dial. Turn this dial to the
right to increase the gain and to the left to decrease it.
2. Remove the adhesive covering from the emitter and place it over the IR
receiver of the 3rd party device (cable box, television, etc.).
1
2

6
Total Control MRX-12
Owner’s Manual
Connecting RS 232 (serial):
The MRX-12 can operate equipment via RS-232 communication. The allows discrete
serial commands to be triggered from the Total Control system.
Connect RS-232 device using URC’s proprietary RS-232 cables. These use either
male or female DB-9 connections with standard pin-outs.
1. Connect the 3.5mm into the RS 232 Output available on the MRX-12.
2. Connect the Serial connection onto the available port on the 3rd party
device, such as AVRs, Televisions, Matrix Switchers, and other devices.
1
2

7
Total Control MRX-12
Owner’s Manual
Specifications
Microprocessor: ARM Cortex-A5 Processor 536MHz
Memory: eMMC 4GB
RAM: SDRAM 1GB x2
Network: RJ45 10/100/1000 (Shielded LAN cable is recommended.)
USB: USB 2.0 A Type Plug
IR Outputs: Six (6) standard 3.5mm IR emitter ports
Relay: 3-pin Terminal
DC Out: 12V/0.2A 2-pin Terminal
Sensor: Two (2) programmable sensor ports
RS 232: Two (2) programmable sensor ports
Power: 12.0V 3.3A
Operating Temp: 0-40 ℃
Size: 140 x 433 x 42.6 (mm)
Weight: 1370g
Limited Warranty Statement
1. Limited Warranty and Disclaimers
Universal Remote Control, Inc. (“URC”) warrants that the URC equipment shall be
free from defects in material and workmanship under normal usage for one (1)
year from purchase when such is purchased from URC. This limited warranty is
valid only in the United States of America. URC warrants that the software
will substantially conform in any material respect to its functional specifications at
the time of delivery. URC SHALL N T BE LIABLE F R PERATI NAL, TECHNICAL
R EDIT RIAL ERR RS AND/ R MISSI NS MADE IN THE URC
D CUMENTATI N. URC D ES N T WARRANT THAT THE URC S FTWARE IS
BUG-FREE R ERR R FREE R THAT THERE ARE N ERR RS/BUGS IN THE URC
S FTWARE.
URC warrants that at the time of purchase the URC equipment and the URC
software complied with all applicable regulations and policies of the Federal
Communications Commissions (“FCC”) regarding electromagnetic interference
caused by electronic/computing devices and to the extent that the URC equipment
and/or the URC software fails to so comply, URC shall, at its own expense, take all
reasonable measures to promptly cause such to comply.
URC equipment purchases from other than an authorized URC dealer or
distributor are without warranty.
THIS LIMITED WARRANTY D ES N T C VER TECHNICAL ASSISTANCE F R
HARDWARE R S FTWARE USAGE EXCEPT AS EXPRESSLY PR VIDED F R
HEREIN, THE EQUIPMENT, S FTWARE AND D CUMENTATI N F URC ARE
SUPPLIED “AS IS” WITH UT ANY WARRANTY, EXPRESS, STATUT RY R
IMPLIED, F ANY KIND. T THE MAXIMUM EXTENT PERMITTED BY APPLICABLE
LAW, URC EXPRESSLY DISCLAIMS ALL WARRANTIES, EXPRESS, STATUT RY R

8
Total Control MRX-12
Owner’s Manual
IMPLIED, INCLUDING BUT N T LIMITED T THE WARRANTIES F
MERCHANTABILITY AND FITNESS F R A PARTICULAR PURP SE. URC D ES N T
WARRANT, GUARANTEE, R MAKE ANY REPRESENTATI NS REGARDING THE
USE F, R THE RESULTS F THE USE F, THE EQUIPMENT, S FTWARE R
D CUMENTATI N IN TERMS F C RRECTNESS, ACCURACY, RELIABILITY R
THERWISE. EXCEPT AS EXPRESSLY PR VIDED F R HEREIN, TECHNICAL
SERVICES ARE SUPPLIED “AS IS”, WITH UT ANY WARRANTY, EXPRESS,
STATUT RY R IMPLIED, F ANY KIND. T THE MAXIMUM EXTENT PERMITTED
BY APPLICABLE LAW, URC EXPRESSLY DISCLAIMS ALL WARRANTIES, EXPRESS,
STATUT RY R IMPLIED, INCLUDING BUT N T LIMITED T THE WARRANTIES
F QUALITY R REAS NABLE SKILL AND CARE, R UTC ME R RESULTS.
WITH UT IN ANY WAY LIMITING THE GENERALITY F THE THER PR VISI NS
HEREIN, WARRANTY D ES N T C VER: (I) DAMAGE FR M MISUSE, NEGLECT
R ACTS R NATURE, (II) M DIFICATI NS, (III) INTEGRATI N WITH THIRD PARTY
C NTENT (IV) BEY ND THE WARRANTY PERI D AND/ R FAILURE T F LL W
URC WARRANTY CLAIM PR CEDURE.
The warranty limitations and warranty disclaimers may not apply to end user in
whole or in part, where such are restricted or excluded by applicable law and such
shall apply to the maximum extent permitted by applicable law.
In the event of any warranty claim, URC will, at its sole option, repair the URC
equipment using new or comparable rebuilt parts, or exchange the URC equipment
for new or rebuilt equipment. In the event of a defect, these are the end user’s
exclusive remedies.
All the URC equipment returned for service, exchange or repair require an RGA
number. To obtain an RGA number, you must complete a Return Request Form
which you may obtain by calling (914) 835-4484 or contacting URC at
deliver the URC equipment, freight prepaid, in its original packaging or packaging
affording adequate protection to URC at 420 Columbus Avenue, Valhalla, NY 10595.
It is end user’s responsibility to backup any macro programming, artwork,
software or other materials that may have been programmed into the unit. It is
likely that such data, software, or other materials will be lost during service and
URC will not be responsible for any such damage or loss. A dated purchase
receipt, bill of sale, installation contract or other verifiable proof of purchase is
required. For the URC equipment support and other important information, please
visit URC's website available at www.universalremote.com or call the Customer
Service Center at (914) 835-4484.
This limited warranty only covers the URC equipment issues caused by defects in
material or workmanship during ordinary consumer use. It does not cover product
issues caused by any other reason, including but not limited to product issues due
to commercial use, acts of God, third-party installation, misuse, limitations of
technology, or modification of or to any part of the URC equipment. This limited
warranty does not cover the URC equipment sold as used, as is, refurbished, so
called "B stock" or consumables (such as batteries). This limited warranty is invalid
if the factory applied serial number has been altered or removed from the URC
equipment. This limited warranty specifically excludes the URC equipment sold by
unauthorized resellers.
With the exception of URC’s IR-only, broad-based consumer remotes, none of Page
36 URC’s PC programmable remotes or any of our Total Control® whole-house
equipment are authorized for online internet sales. Buying URC’s PC programmable
remotes or any of our Total Control® whole-house equipment online means
buying equipment that does not have a URC’s limited warranty. Such equipment is
not eligible for URC tech support or software support, either.

9
Total Control MRX-12
Owner’s Manual
2. URC’s Limitations of Liability
IN N EVENT SHALL URC BE LIABLE F R INDIRECT, SPECIAL, INCIDENTAL,
EXEMPLARY, PUNITIVE R C NSEQUENTIAL DAMAGES F ANY KIND R L SS
F PR FITS R BUSINESS PP RTUNITY, EVEN IF URC IS ADVISED F THE
P SSIBILITY F SUCH DAMAGES.
IN N EVENT SHALL URC BE LIABLE F R L SS F R DAMAGE T DATA,
C MPUTER SYSTEMS R C MPUTER PR GRAMS. URC’S LIABILITY, IF ANY, F R
DIRECT DAMAGES F ANY F RM SHALL BE LIMITED T ACTUAL DAMAGES,
N T IN EXCESS F AM UNTS PAID BY END USER F R THE URC EQUIPMENT.
IN N EVENT SHALL URC BE LIABLE F R ANY EVENTS BEY ND ITS C NTR L,
INCLUDING ANY INSTANCE F F RCE MAJEURE. IN N EVENT SHALL URC BE
LIABLE F R THE ACTS R MISSI NS F END USER R ANY THIRD PARTY.
THE LIMITATI NS F LIABILITY MAY N T APPLY T END USER IN WH LE R IN
PART, WHERE SUCH ARE RESTRICTED LIMITED R EXCLUDED BY APPLICABLE
LAW AND SUCH SHALL APPLY T THE MAXIMUM EXTENT PERMITTED BY
APPLICABLE LAW.
URC SHALL N T BE HELD RESP NSIBLE F R THE STATEMENTS MADE BY
THERS.
S ME STATES R JURISDICTI NS D N T ALL W THE EXCLUSI N R
LIMITATI N F INCIDENTAL R C NSEQUENTIAL DAMAGES, R ALL W
LIMITATI NS N H W L NG AN IMPLIED WARRANTY LASTS, S THE AB VE
LIMITATI NS R EXCLUSI NS MAY N T APPLY T END USER. THIS LIMITED
WARRANTY GIVES END USER SPECIFIC LEGAL RIGHTS AND END USER MAY
HAVE THER RIGHTS WHICH VARY FR M STATE T STATE R JURISDICTI N T
JURISDICTI N.
End User Agreement
The terms and conditions of the End User Agreement available at
www.universalremote.com/eua.php shall apply.
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one more of the
following measures:
●Reorient or relocate the receiving antenna.
●Increase the separation between the equipment and receiver.
●Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
●Consult the dealer or an experienced radio/TV technician for help.

10
Total Control MRX-12
Owner’s Manual
Warning!
Changes or modifications not expressly approved by the manufacturer could void the
user's authority to operate the equipment.
Note : The manufacturer is not responsible for any Radio or TV interference caused by
unauthorized modifications to this equipment. Such modifications could void the user's
authority to operate the equipment.
FCC Caution
This device complies with Part 15 of the FCC Rules. peration is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for
compliance could void the authority to operate equipment.
Regulatory Information to the User
●CE conformity Notice
Products with “CE” marking comply EMC Directive 2014/30/EU issued by the
commission of the European Community.
1. EMC Directive
●Emission
●Immunity
●Power
●Declaration of Conformity
“Hereby, Universal Remote Control Inc. declares that this MRX-12 is in compliance
with the Essential requirements”
Table of contents
Other URC Controllers manuals
Popular Controllers manuals by other brands

Kirby Morgan
Kirby Morgan SuperFlow 350 Regulator manual

Ridder
Ridder HortiMaX-Go user manual

Agilent Technologies
Agilent Technologies Turbo-V 81-AG user manual

vanEE
vanEE DEHUMIDISTAT CONTROL 41302 Installation and user guide

industrie technik
industrie technik SE25M24 instructions

Vega
Vega VEGATOR 132 operating instructions