General notes and limitations
The 1133/15 Universal handset will replace 5or 2 wire handsets. It will not replace 3, 4, 6 etc wire
handsets.
The call volume adjustment does not work in the AC buzzer call configuration.
In electronic call configuration the handset will not ring if it is off the hook.
Important –Please read
The 1133/15 Universal handset is designed to replace only the handsets in the
tables on Pages 2and 3.
This manual contains all of the available information to enable the Universal
handset to replace handsets in these tables.
Technical support for this product is available by e-mail only.
E-mail details of the fault and details of the handset being replaced, including clear
pictures of the handset terminal markings to [email protected]
Ensure that you have read this manual before contacting Urmet Technical Support
Note that Urmet Technical Support are only able to offer advice regarding the
1133/15 Universal handset and not third party equipment.
1

Urmet
1133/15 9 2 6 1 CA (E) CA (R)
Manufacturer Lock
release
Speech
(handset to
entry
panel)
Ground
Speech
(entry
panel to
handset)
Call
(Electronic
tone)
Call
(12V AC
Buzzer)
ACET
5
10
2
7
9
ACET
-
ANTENOPHONE901
5
10
2
7
9
ACET
-
ANTENOPHONE701
7
3
6
4
5
AIPHONE (poste
CVK)
4
1
3
2
B
AMPER
D
A
C
B
E
AMPLIVOX
Z
T
0
R
1
AMPLIVOX
Z
8
0
T
1
AMPLIVOX
2
T
0
R
1
ATEA
2
4
3
1
5
AUTA TF92
10
3
4
7
12
AUTELCO
P5
a
1
b
2
BELL SYSTEMS
Z
R
0
T
I
BITRON
AN0002
9
2
6
1
C7
11
BOGEN
T
1
3
2
6
BPT
2
1
4
5
3
CENTRAMATIC
4
2
1
3
5
CEVAM
870
2
6
9
4
R
CITESA
1
4
C
3
B
CITOFONIX
3
1
2
4
5
CITOVOX
5
10
9
7
T
COFREL TERANEO
LT
T
2
3
1
6
COMELIT
2100
P1
3
4
2
1
COMELIT 2300
P1
3
4
2
5
ELBEX
MIC
LOW
SPEC
+
ELBOX
2
6
9
4
+
ELBOX
7
2
3/4/5
1
6
FARFISA
5
1
3
2
6
FERMAX
1
2
3
6
4
FERMAX 2044,
20440, 21100
1
2
3
6
4
FERMAX GONDOLA
4
1
3
2
V/5
FERMAX REKTO TF
-
4
P
A
C
B
E
FRINGE
2
3
1
6
4
GAME
P
2
3
1
Z
GIRO
2
3
1
6
4
GOLMAR
X
M
A
S
N
GOLMAR
C2
5
3
10
7
GOLMAR
11
5
3
4
12
GOLMAR T
-
2800
4
5
3
10
7
GOLMAR T
-
600
T
1
3
2
6
LT TERRANEO
COFREL
T1
1
3
2
6
OSTELVI
9
2
6
1
7
PORMAT
4
3
2/5
1
V
2

RIPO
LLES
3
1
8
2
4
RITTO ELEGANT
40518
11
12
13
15
14
SAFNAT
4
1
2
3
V
SELTI
5
1
3
2
6
SIEDLE HTA 711
-
01
I
12
9/C
11
7
SPRINT
/
1
3
2
6
STR NH200
1
M
0
T
S
STR NH205
1
M
0
T
S
TAGRA
8
2
6
1
4
TEGUI GL
3
4
2
5
1
TEGUI HORIZON
(elec.)
3
4
2
5
1
TEGUI HORIZON
(Zum.)
3
4
2
5
1
TELEVES
4
2
3
1
T
TESLA DDZ 85
1
2
3
6
4
TESLA DDZ93
Z
2
3
6
4
TUNE
8
2
6
1
4
URMET
8/9
2
11
1
7
URMET
1130
9
2
6
1
7
URMET
1131, 1132, 1133
9
2
6
1
CA
VIDEX
5
1
7
2
6
YUS PHONE
E/L
T
-
R
B/PT
TRANSIF
ON
1
5
6
7
4
VEMEL
5
2
3
4
1
VIDEX
5
1
7/3
2
4
6
VISIDIS (OKAY)
5
2
4
3/6
1
2-Wire handsets
Urmet
1133/15 1 2 (E) (R)
Manufacturer
Ground
Speech/call
Electronic call
tone
Call by buzzer
ACET 702
5
6
*
LT TERRANEO
603
4
1
*
SELTI/VIDEX 52
5
3
1
*
TONNA/VIDEX
5
6
*
URMET 1130/50/2F
1
2
*
3

How to use the above tables.
Using the Videx handset as an example –
Videx Urmet 1133/15
5 9
1 2
7 6
2 1
6CA (JPA jumper in the Rposition)
5-Wire terminal functions
2-Wire terminal functions
2
6
10
9
CA
1
G/T
T1
Spare button. Normally open volt free contact
Ground (0V)
Speech, call and lock release
6
1
7
2
5
2
6
10
9
CA
1
G/T
T1
Videx
1133/5
113
3
/15
1133/15
4
Lock release
Ground (0V)
Speech from handset to entry panel
Speech from entry panel to handset
Call
Spare button. Normally open volt free contact
2
6
10
9
CA
1
G/T
T1
You must make this link
You must
make this link
You must make
these links

Jumpers and settings
Note –The 1133/15 Handset default settings are for 5-wire AC buzzer type handsets
Replacing 5-Wire handsets
Jumpers JP1 to JP5 must all be as shown (position 5) –
Note
–
The JPC jumper must
always be in the + position
If you are using the 1133/15 to replace a 5-wire buzzer type
handset you do not need to move any jumpers
5

6
Electronic call (through the handset speaker)
If the handset you are replacing does not have a buzzer i.e. it calls through the handset speaker, then the
JPA jumpermust be in position E
AC Buzzer call
If the handset you are replacing
h
as an
AC
then the
JPA
jumper
must be
in position
R
AC Buzzer call Electronic call (through the handset speaker)
JPA jumper in
the Rposition
JPA jumper in
the Eposition

Replacing 1 + n (2-wire) handsets
Jumpers JP1 to JP5 must all be as shown (position 2) –
If the 2-wire handset you are replacing has AC buzzer call then the JPA jumper must be in the Rposition.
If the handset has electronic call the JPA jumper must be in the Eposition.
See Page 6 for details
Volume controls for 2-wire handsets –
Turn the SPK control fully clockwise
Turn the MIC control to approximately half way
Note
–
The JPC jumper must
always be in the + position
7

Volume controls –All handsets
Use the SPK (handset speaker) and MIK (handset microphone)to make the required volume
adjustments.
Turn clockwise to increase the volume and anti-clockwise to reduce the volume.
Any problems with feedback (high pitch whistling) must be corrected using these controls.
Fault finding
No call Change the JPA jumper position
High pitch whistling (feedback) Adjust the handset MIC and SPK controls
No lock release Check the jumper between terminals 6 and 10 is in place
If the original fault was no lock release for example, and after the 1133/15 Universal handset is fitted
you have the same problem, then the fault lies elsewhere in the system.
In this case do not contact Urmet Technical Support.
URMET COMMUNICATION
AND SECURITY UK LTD
Urban Hive, Skyline 120,
Avenue West, Great Notley,
Essex. CM77 7AA
www.urmet.co.uk
technical
@urmet.co.uk
8
Table of contents
Other urmet domus Handset manuals