V-TEK DT607C-S1 User manual

USER MANUAL
DT607C-V1 / 201608
• Please read this manual carefully to ensure safe and correct operation
• Keep this manual for future reference
DT607C-S1 DT607C-S2
DT607C-S3 DT607C-S4
MODEL DT607C
2-WIRE SERIES


CONTENTS
PARTS AND FUNCTIONS
PartsNames 1
Mounting 1
External Motion Detection 2
SETUP INSTRUCTIONS 3
Functions Setting Up 3
Setting Door Station Address 4
Setting Door Station Calling Mode 4
Setting Unlock Mode 6
Setting Unlock Time 6
Setting Nameplate Illumination Mode 7
Setting Night View LED Illumination Mode 7
Setting Ring Tone 8
WIRING 9
Connecting Electric Lock 9
Connecting 1-Monitor Kit 10
Connecting Multiple Door Stations 10
Connecting Multiple Monitors 11
APPENDIX 13
Precautions 13
Specications13
Cable Requirments 14

-1-
Parts Names
PARTS AND FUNCTIONS
[11] [10]
[9]
[1]
[3]
[4]
[8]
[7]
[6]
[5]
[12]
[13]
[2]
[1] Microphone
[2] UNLOCK indicator
[3] CALL indicator
[4] Call button
[5] Nameplate
[6] Front panel
[7] Speaker
[8] Night view LED
[9] Camera lens
[10] Rain cover
[11] Mounting hook
[12] Connection port
[13] Screw hole
Mounting
1 2 3 4 5
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
Rain cover
Rainy cover
The distance between
the top of main unit
and rain cover should
be not less than 3mm.
Main unit
Main unit
≥3mm
1. Connect the cable
2. Drill holes in the wall to match the size of screw stoppers,then attach the rain cover and
main unit to the wall.Distance between the top of main unit and rain cover should be not less
than 3mm
3. Install the name plate
4. Attach the front cover to the main unit
5. Use supplied allen key and the screws to x the cover
The installation height is suggested to 145~160cm

-2-
PARTS AND FUNCTIONS
Terminals description
Lock Control Jumper: To set lock type
Motion Detector Connection Port: To connect external PIR motion
detector
Main Connection Port: To connect the bus line and the electric lock
• L1,L2: Connect bus line, no-polarity
• PL: External lock power input, connect to the power positive (power +).
• S+: Lock power(+) output
• S-: Lock power(-) output, connect to the power(-) input of lock(only when lock is powered
from the Door Station)
1 2 3
Lock Control Jumper
PIR Motion Detector
Connection Port
+12V
GND
PIR
L1 L2
PL
S+ S-
Main Connection Port
External Motion Detection
The door station is equipped with a terminal to
connect external motion detector sensor
If the external motion detector is connected to
the system and it detect someone passing by, it
will turn on security light. Additional DT-RLC is
required
12V
Motion
detector
GND
PIR

-3-
SETUP INSTRUCTIONS
Functions Setting Up
KEY_1
KEY_2
KEY_3
KEY_4
KEY_SET
LED_UNLOCK
LED_TALK
LED_NAME
This section explains the settings of each
function. Please refer to the following table.
To perform the settings for the function
you want, you should remove door station
cover plate
Each operation is indicated by the lighting
up of the LED indicator on the unit and by
the sounding of the buzzer.
Order Setting items Setting range Default value
1 Setting door station address 0~3 0
2Setting door station
calling mode Standard/Group calling mode Standard calling mode
3 Setting the unlock mode 0:opened/1:closed 0:opened
4 Setting the unlock time 01 to 99 seconds 1 seconds
5Setting the nameplate
illumination mode On/Off/Auto On
6Setting night view LED
illumination mode On/Off/Auto Auto
7 Setting ring-back tone
Ringing ones
Ring continuously
No ring-back tone
Ringing ones

-4-
Setting Door Station Address
Setting Door Station Calling Mode
Total 4 addresses can be congured. It can be modied either before or after installation.
0 is default, to change the setting, please follow the steps:
UNLOCK Indicator:OFF
TALK Indicator:OFF Buzzer Beep+, Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer
Beep+
In standby mode, press
KEY_SET button once
Press KEY_1 button to set
as first door station
Press KEY_2 button to set
as second door station
Press KEY_3 button to set
as third door station
Press KEY_4 button to set
as fourth door station
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer
Beep,Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer
Beep,Beep,Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer
Beep,Beep,Beep,Beep
ID=0,1st door station ID=1,2nd door station ID=2,3rd door station ID=3,4th door station
SETUP INSTRUCTIONS
• If setting mode has not been exited, you can change the address of door station by pressing KEY1~4
• The LED_NAME indicator will blink until the setting mode is exited
• No operation for 10 seconds will exit the setting mode automatically
• Press KEY_SET button four times to exit the setting mode manually
There are two calling modes for door station: Standard calling mode and Group calling mode
Standard Calling Mode is default

-5-
• If setting mode has not been exited, you can change the calling mode by pressing KEY1 circularly
• The LED_NAME indicator will blink until the setting mode is exited
• No operation for10 seconds will exit the setting mode automatically
• Press KEY_SET button three times to exit the setting mode manually
SETUP INSTRUCTIONS
Refer to the manual for Video Monitor for more info about monitor address setting
Each call button will respond different addresses when set in different calling modes
Refer to the following for more information
Call buttonA: call the monitor with address 01 by default
Call buttonB: call the monitor with address 02 by default
Call buttonC: call the monitor with address 03 by default
Call buttonD: call the monitor with address 04 by default
Call buttonA: Call all monitors in group address from
00~15 (one of the monitor should be set to 00)
Call button B,C,D: Call all monitors in group address
from 16~31 (one of the monitor should be set to 16)
UNLOCK Indicator:OFF
TALK Indicator:ON
Buzzer
Beep+, Beep
In standby mode, press
KEY_SET button twice
UNLOCK Indicator:OFF
TALK Indicator:ON
Buzzer
Beep+
Press KEY_1 button to
activate Standard calling
mode for door station
UNLOCK Indicator:OFF
TALK Indicator:ON
Buzzer
Beep, Beep
Press KEY_1 button again
to activate Group calling
mode for door station
Press KEY_1
A
B
C
A
B
C
D
A A
B
1.Standard Calling Mode
(Address range 01-04 default)
2.Group Calling Mode
To change this setting, please follow the steps:

-6-
SETUP INSTRUCTIONS
Setting Unlock Mode
There are 2 unlock modes, Normally opened and Normally closed
Normally opened is default.To change
it,
please follow the steps:
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button three
times
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+
Press KEY_1 button to set
the unlock mode to
Normally opened
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep, Beep
Press KEY_1 button again
to set the unlock mode to
Normally closed
Press KEY_1
• If setting mode has not been exited, you can change the unlock mode by pressing KEY1 circularly
• The LED_NAME indicator will blink until the setting mode is exited
• No operation for 10 seconds will exit the setting mode automatically
• Press KEY_SET button twice to exit the setting mode manually
Setting Unlock Time
Default unlocking time is 1s.Can be changed to anything from range 1s~99s
Follow the steps:
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button three
times
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer
Beep,Beep......
Press and hold on KEY_2
button. The time you holding
on is the new unlock time
• When entering time delayed setting, the buzzer soundsonesper second
• The LED_NAME indicator will blink until the setting mode is exited
• No operation for 10 seconds will exit the setting mode automatically
• Press KEY_SET button twice to exit the setting mode manually

-7-
SETUP INSTRUCTIONS
Setting Nameplate Illumination Mode
There are 3 illumination modes for nameplate:Normally On,Normally Off and Auto
Normally On is default.To change the setting, please follow the steps:
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer
Beep+, Beep
In standby mode, press
KEY_SET button three
times
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer
Beep+
Press KEY_3 button to set
the nameplate illumination
mode to Normally On
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer
Beep, Beep
Press KEY_3 button again
to set the nameplate illumina-
tion mode to Normally off.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer
Beep, Beep,Beep
Press KEY_3 button again and
again to set the nameplate
illumination mode to Auto
Press KEY_3
• If setting mode has not been exited, you can change the nameplate illumination mode by pressing KEY3
circularly
• The LED_NAME indicator will blink until the setting mode is exited
• No operation for 10 seconds will exit the setting mode automatically
• Press KEY_SET button twice to exit the setting mode manually
Setting Night View LED Illumination Mode
There are 3 working modes for night view LED indicator:Normally On,Normally Off,Auto
Auto is default.To change the setting, please follow the steps:
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer
Beep+, Beep
In standby mode, press
KEY_SET button three
times
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer
Beep+
Press KEY_4 button to set
the night view LED mode
to Normally On
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer
Beep, Beep
Press KEY_4 button again
to set the night view LED
mode to Normally Off
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer
Beep, Beep,Beep
Press KEY_4 button again
and again to set the night
view LED mode to Auto
Press KEY_4
• If setting mode has not been exited, you can change the night view LED illumination mode by pressing
KEY4 circularly
• The LED_NAME indicator will blink until the setting mode is exited
• No operation for 10 seconds will exit the setting mode automatically
• Press KEY_SET button twice to exit the setting mode manually

-8-
SETUP INSTRUCTIONS
Setting Door Station Ringtone
There are 3 ringtone options available to choose from: Ringing ones,Ringing continuously
and No ringtone
Ringing onesis default. To change the setting, please follow the steps:
UNLOCK Indicator:ON
TALK Indicator:ON
Buzzer
Beep+, Beep
In standby mode, press
KEY_SET button four
times
UNLOCK Indicator:ON
TALK Indicator:ON
Buzzer
Beep+
Press KEY_1 button to set
the ringtone sounding ones
UNLOCK Indicator:ON
TALK Indicator:ON
Buzzer
Beep, Beep
Press KEY_1 button again
to set the ringtone sounding
continuously
UNLOCK Indicator:ON
TALK Indicator:ON
Buzzer
Beep, Beep,Beep
Press KEY_1 button again
and again to choose silent
Press KEY_1
• If setting mode has not been exited, you can change the ringtone by pressing KEY1 circularly
• The LED_NAME indicator will blink until the setting mode is exited
• No operation for 10 seconds will exit the setting mode automatically
• Press KEY_SET button once to exit the setting mode manually

-9-
Connecting Electric Lock
Door Lock Controlled with Internal Power
Door Lock Controlled with Dry Contact
1.Electronic lock of Power-on-to-unlock
type should be used
2.The door lock is limited to 12V, and
holdingcurrent must beless than
250mA
3.The jumper should be placed on position
2 and 3 before connecting the lock
4.The door lock control is not timed from
Exit Button(EB). Can be timed with
additional RLC Lock Control Interface
5.The Unlock Mode must be set to 0
(default)
1.The external power supply must be used
according to the lock specs
2.The inside relay contact is restricted to
230Vac 1A or 24Vdc 1A
3.The jumper must betaken off
before connectingthe lock
4.Set the Unlock Mode according to
different lock types:
• Power-on-to-unlock type:Unlock
Mode=0 (default)
• Power-off-to-unlock type:Unlock
Mode=1
EB
*
LOCK
Jumper position on 2&3
1 2 3
L1 L2 PL S+ S-
Take off the jumper
1 2 3
L1 L2 PL S+ S-
LOCK
POWER
SUPPLY
WIRING
* DT-RLC Lock Control Interface is needed to connect second lock or to make EB timed

-10-
WIRING
• Max.4 door stations can be connected to the system
• Ensure to set the correct address for each door station, Refer to Page 7 for more details
about the door stations address settings
Connecting 1- Monitor and 1-Door Station System
Connecting Multiple Door Stations
BUS(IM) BUS(DS)
-
+
L1 L2 PL S+ S-
ID=0
Code=1, DIP6=on
1 2 3 4 5 6
ON DIP
L2
L1
DIP Switches
PC6A
AC~
100~240VAC
100~240VAC
DBC4A1
A B C D
OFF
ON
Impedance
switch
BUS(IM) BUS(DS)
PC6A
AC~
ID=0
1st door station
ID=1
2nd door station
ID=2
3rd door station
ID=3
4th door station
L1 L2 PL S+ S- L1 L2 PL S+ S- L1 L2 PL S+ S- L1 L2 PL S+ S-
To monitors
• The door station work in Standard mode in this situation. Refer to Page 8 for details

-11-
Daisy Chain In-Out Wiring Door Station in Standard Mode
Connecting Multiple Monitors
WIRING
• Recommended for up to 4-Monitors system
• All monitors in the system should have
same User code 1
• Program first monitor as ‘Master’ and
others as ‘Slave’ 1, 2 and 3
• Flip DIP-6 on the last monitor to On
(end of line)
ID=0
Code=1, DIP6=off
Optional functional module
SCU
CCTV Interface
GSM
Interface
TPS
Telephone Interface
QSW
Quad CCTV Interface
(Master)
Code=1, DIP6=off
(Slave 2)
Code=1, DIP6=on
(Slave 3)
BUS(IM) BUS(DS)
PC6A
AC~
100~240VAC
Code=1, DIP6=off
(Slave 1)
SCU GSM TPS QSW

-12-
• Recommended for systems with up to 15 video monitors
• All video monitors must have a unique User Code starting with Code 0-15
WIRING
DBC4A1
A B C D
RLC DBC4A1
OFF ON
Impedance
switch
BUS(IM) BUS(DS)
Code=
0
,DIP6=on Code=
1
,DIP6=on
Code=
2
,DIP6=on Code=
3
,DIP6=on
ID=0
PC6A
AC~
100~240VAC
Optional
Interfaces
BDU
BDU
signal
amplifier module
RLC staircase light controller module
DBC4A1 2/4 inputs branch distributor
Star Wiring Door Station in Group Calling Mode
DBC4A1
A B C D

-13-
Precautions
Specification
• Please clean the unit with soft cotton cloth, don't use the organic impregnant or chemical
clean agent. If necessary, please use a little pure water or dilute soap water to clean the dust
• The unit is weather resistant. However do not spray high pressure water onto door station
directly. Excessive moisture may cause problems
• You must use only original Intelligent Power supply which is supplied or approved by the
manufacturer
• Pay attention to the high voltage inside the products, please refer service only to a trained
and qualied professional
APPENDIX
Power supply: DC 24V
Power consumption: Standby 0.8W; Working 3W
Camera lens: Color CMOS, 520TVL
1/4’’ camera,1050angle of view
Lock Power supply: 12Vdc, 280mA(Internal Power);
Number of relay circuits: 2(second lock need external power supply)
Mounting: Surface mount
Working temperature: -20ºC ~ +55ºC
Protection: IP54
Material: Zinc alloy
Wiring: 2 wires, no-polarity
Dimension: H176×W90×D24mm

-14-
APPENDIX
Cables and Requirments
The maximum distance of the wiring is limited in the DT system. Using different cables may also
affect the maximum distance which the system can reach
Cable and distance(unit:m)
Cable Usage A B
≤2 IM
B
≤16 IM
Twisted cable 2x0.75mm260 100 40
Twisted cable 2x1mm280 120 60
A
B
PC6A
Basic IN-OUT Wiring Mode

-15-
B
A
C
2
2
DBC4A1
PC6A
Cable and distance(unit:m)
Cable Usage A B C
Twisted cable 2x0.75mm260 60 30
Twisted cable 2x1mm280 80 40
APPENDIX
Star Topology Wiring Mode With DBC4A1

-16-
Note

The design and specifications can be changed without notice to the user. Right to interpret and copyright of this
manual are preserved.
DT-ENG-DT607C-V1
This manual suits for next models
3
Table of contents