PROGRAMMING OPTIONS
Set Alarm Relay Time (Default = 5 sec)
Enter Programming Mode {Alternating Red & Green LED}
Press 2 + [00-99 seconds] + # {Alternating Red & Green LED}
Press # to exit Programming {Solid Red LED}
NOTE: The Alarm Relay is used for Forced Door & Door Prop alarms. 00 = Non-stop alarm – Reset by using a valid card.
Enable Forced Door Alarm Relay (Default = Force Door Disabled)
Enter Programming Mode {Alternating Red & Green LED}
To enable, Press 841 + # {Alternating Red & Green LED}
To disable, Press 840 + # {Alternating Red & Green LED}
Press # to exit Programming {Solid Red LED}
NOTE: A Door Position Sensor must be installed.
Enable & Set Door Prop Time (Default = Door Prop Disabled)
Enter Programming Mode {Alternating Red & Green LED}
To enable, Press 881 + # {Alternating Red & Green LED}
Press 3 + [01-99 seconds] + # (sets Door Prop Time; Default = 00) {Alternating Red & Green LED}
To disable, Press 880 + # {Alternating Red & Green LED}
Press 300 + # {Alternating Red & Green LED}
Press # to exit Programming {Solid Red LED}
NOTE: A Door Position Sensor must be installed. Relay will remain activated until the door closes OR the Alarm Relay
time expires, whichever occurs first.
Set Shunt Relay Time (Default = Shunt Disabled)
With the Shunt Relay Enabled, the Auxiliary (K3) Relay will activate simultaneously with the Strike Relay:
Enter Programming Mode {Alternating Red & Green LED}
To enable, Press 812 + # {Alternating Red & Green LED}
Press 0 + [01-99 seconds] + # (sets Shunt Relay Time; Default = 01) {Alternating Red & Green LED}
To disable, Press 810 + # {Alternating Red & Green LED}
Press # to exit Programming {Solid Red LED}
NOTE: DIP SWITCH 1 on the E5RM control module, must be ON. Shunt cannot be used if Anti-Duress is enabled.
Set Anti-Duress Relay Time (Default = Anti-Duress Disabled)
With the Anti-Duress Relay Enabled, the Auxiliary (K3) Relay will activate when the Door Open Password (See Factory
Defaults) OR a User’s PIN (Entry Mode 2 ONLY), is entered, followed by a ‘9’:
Enter Programming Mode {Alternating Red & Green LED}
To enable, Press 811 + # {Alternating Red & Green LED}
Press 0 + [01-99 seconds] + # (sets Duress Relay Time; Default = 01) {Alternating Red & Green LED}
To disable, Press 810 + # {Alternating Red & Green LED}
Press # to exit Programming {Solid Red LED}
NOTE: DIP SWITCH 1 on the E5RM control module, must be ON. Anti-Duress cannot be used if Shunt is enabled.
Enable Reader Lockout (Default = Disabled)
Enabling this function will do the following:
1. If an invalid card or card number is used (5) times in a row, this option will “Lockout” the keypad for approx. 1 minute.
2. In Entry Mode 2, if an invalid PIN number is entered over (5) times, the card will automatically be deleted.
Enter Programming Mode {Alternating Red & Green LED}
To enable, Press 851 + # {Alternating Red & Green LED}
To disable, Press 850 + # {Alternating Red & Green LED}
Press # to exit Programming {Solid Red LED}
Set Door Status Sensor Configuration (Default = Normally Open)
Enter Programming Mode {Alternating Red & Green LED}
For Normally Closed, Press 861 + # {Alternating Red & Green LED}
For Normally Open, Press 860 + # {Alternating Red & Green LED}
Press # to exit Programming {Solid Red LED}
P:\INSTALLATION INST\Access Controls\INST-E4KP\INST-E4KP.vsd Rev C 10-09 Page 4