SDC E4KP ENTRYCHECK User manual

Security Door Controls
801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 • Fax: (805) 494-8861
www.sdcsecurity.com • E-mail: service@sdcsecurity.com
The E4KP EntryCheck™ is a fully self-contained proximity access control reader. It is keypad programmable and
does not require software or a PC connection.
INSTALLATION/PROGRAMMING INSTRUCTIONS
E4KP ENTRYCHECK
™
P:\INSTALLATION INST\Access Controls\INST-E4KP\INST-E4KP.vsd Rev C 10-09 Page 1
Features
HID compatible Proximity Reader
Up to 3" read range with ProxCard II
Weather resistant reader enclosure
Memory capacity stores up to 650 user cards
Cost-effective solution for access control and
personnel management
Access mode selectable
1. Proximity card only
2. Proximity card + PIN
Master code for programming functions
Main password function
Security password function
Forced entry alarm
Door prop alarm
Duress output
User card can be registered/deleted in single
or batch mode (with consecutive numbers)
Reader Lockout activated when the wrong card is
presented more than five times
Lock and alarm output relays programmable
1-99 seconds or on-off latching
Separate remotely located relay module for
for higher security
Optional Cards & Key Fobs
Part# HID1326-10 –(10) Prox Cards, HID ProxCard II
Part# HID1346-10 –(10) Prox Key Fobs, HID ProxKey II
HID ProxCard® II & ProxKey® II are registered trademarks of HID Corporation

P:\INSTALLATION INST\Access Controls\INST-E4KP\INST-E4KP.vsd Rev C 10-09 Page 2
FACTORY DEFAULTS
System Setup Password…………………………………………………………………...…………………111111 (6 digits)
Door Open Password...…………………………………………………………………………...……………1234 (4 digits)
Door Open Mode……………………………………………………………………………………………………....Read card
Reading Card Data Format…………………………………………………………………………………..Low weight 24Bits
Patrol Password………………………………………………………………………………...…………….1234567 (7 digits)
Duress Password………………………………………………………………..…Door open password or PIN + 9 (5 digits)
Shunt Function………………………………………………………………………………..………………….……….Disabled
Anti-Duress Function………………………………………………………………………………………..…………...Disabled
Patrol function…………………………………………………………………………………………………………….Disabled
Force Entry Alarm…...…………………………………………………………………………………………...………Disabled
Door Prop Alarm Detection Time..……………………………………………..……………………....0 SEC (00 = Disabled)
Door Prop Alarm………………………...………………………………………………………………………….…….Disabled
Password Error over 5 times (keypad lockout for 1 min) OR
PIN Error over 5 times (deletes the cardholder)…………………..…………………………………………....Disabled
Patrol Relay Active Time…………………………………………..………………………………………….……1 SEC (fixed)
Strike Relay Active Time….………………………………………………………….……………5 SEC (00 = LATCH mode)
Alarm Relay Active Time………………………………………….……………………….…...10 SEC (00 = non-stop alarm)
Anti-Duress/Shunt Active Time…………………………….……………………………………………………………...1 SEC
Door Sensor Configuration Detection…………………..…………………………………..………………….Normally Open
BASIC OPERATION
The E4KP has two programmable entry modes:
Mode 1 (Default) – Card Only
Mode 2 – Card (or Enter Card Number) & PIN
In Normal Standby Mode, the LED on the E4KP will be Solid Red.
When the Strike Relay is active, the LED will be Solid Green.
To Open the Door using an HID card or fob (in Mode 1),
Present a valid card or fob within a couple of inches of the reader {Solid Green LED}
To Open the Door using an HID card or fob (in Mode 2),
Present a valid card or fob within a couple of inches of the reader {Slow Flashing Red LED}
Enter the 4-digit PIN + # {Solid Green LED}
QUICKSTART PROGRAMMING INSTRUCTIONS
Before enrolling any cards, the default Door Open Password (1234 + #) may be used to activate the Strike Relay.
Once a card is enrolled, the Door Open Password will no longer function.
The following commands will program a specified number of sequential HID cards, and will set the strike relay time to
5 seconds. You will need the first card in the sequence. This is the card with the lowest card number (see below)
Command LED Indicator
Press 111111 + # {Alternating Red & Green LED}
Press 5 + # {Fast alternating Red & Green LED}
Present the first card in the sequence {Flashing Red}
Enter the total number of cards + # {Fast alternating Red & Green LED}
Press # twice. {Solid Red LED – Normal Standby Mode}
Present any of the cards to the reader. {Solid Green LED – Strike Relay Active}
HID
PROXIMITY
XXXXX XXXXXXXX-1
5-DIGIT
CARD NUMBER

BASIC PROGRAMMING
Entering Programming Mode
Before ANY cards have been enrolled,
Enter the System Setup Password + # {Alternating Red & Green LED}
NOTE: Default System Setup Password is 111111
After a card or card number has been enrolled, (First card programmed is your programming card)
Enter the System Setup Password + # {Fast flashing Red}
Present first card programmed (programming card OR (Enter programming card number + #) {Alternating Red & Green
LED}
Exiting Programming Mode
Press # until the E4KP displays a steady Red LED. (Normal Standby Mode)
NOTE: The E4KP will automatically exit Programming Mode after 10 Seconds of inactivity
Set Strike (Main) Relay Time (Default = 5 Sec)
Enter Programming Mode {Alternating Red & Green LED}
Press 1 + [00-99 seconds] + # {Alternating Red & Green LED}
NOTE: 00 = Latching Mode
Press # to exit programming. {Solid Red LED}
Set Entry Mode (Default is Card OR Card Number)
Enter Programming Mode {Alternating Red & Green LED}
Choose the mode of entry you require & enter the adjacent command: {Alternating Red & Green LED}
Mode 1 – Card Only, Press + 1 + #
Mode 2 – Card (or Enter Card Number) & PIN, Press + 2 + #
Press # to exit Programming {Solid Red LED}
CARD OR KEY FOB ENROLLMENT
IMPORTANT: It is highly recommended that an administrator keep a log of the Card/Key Fob numbers, and who they are
assigned to. The 5-digit card/fob number can typically be found on one side of the HID Card or Fob (See Pg. 2). If a card
ever needs to be deleted, you will need the card or the card number.
Adding a Single Card OR Card Number
Enter Programming Mode {Alternating Red & Green LED}
Press 4 + # {Fast, alternating Red & Green LED}
Present Card OR Enter the Card Number (0 – 65535) + # {Flashing Red LED}
Key in a 4-digit PIN + # (If you do not want to enter a PIN, just Press #) {Fast alternating Red & Green LED}
NOTE: If you choose not to enter a PIN number, the PIN will be set to ‘0000’.
Present the next card to be entered or Press # to exit card enrollment {Alternating Red & Green LED}
Press # again to exit Programming {Solid Red LED}
Adding a Batch of Sequential Cards
Enter Programming Mode {Alternating Red & Green LED}
Press 5 + # {Fast, alternating Red & Green LED}
Present the first sequential card {Flashing Red LED}
Enter the total number of cards + # {Fast, alternating Red & Green LED}
Present the first card of another sequence or Press # to exit card enrollment {Alternating Red & Green LED}
NOTE: The PIN number for all cards enrolled in batch mode is ‘0000’.
Press # again to exit Programming {Solid Red LED}
Deleting a Single Card OR Card Number
Enter Programming Mode {Alternating Red & Green LED}
Press 6 + # {Fast, alternating Red & Green LED}
Present Card OR (Enter the Card Number + #) {Fast, alternating Red & Green LED}
Present/Enter another Card to delete or Press # to exit card deletion {Alternating Red & Green LED}
Press # again to exit Programming {Solid Red LED}
**
P:\INSTALLATION INST\Access Controls\INST-E4KP\INST-E4KP.vsd Rev C 10-09 Page 3

PROGRAMMING OPTIONS
Set Alarm Relay Time (Default = 5 sec)
Enter Programming Mode {Alternating Red & Green LED}
Press 2 + [00-99 seconds] + # {Alternating Red & Green LED}
Press # to exit Programming {Solid Red LED}
NOTE: The Alarm Relay is used for Forced Door & Door Prop alarms. 00 = Non-stop alarm – Reset by using a valid card.
Enable Forced Door Alarm Relay (Default = Force Door Disabled)
Enter Programming Mode {Alternating Red & Green LED}
To enable, Press 841 + # {Alternating Red & Green LED}
To disable, Press 840 + # {Alternating Red & Green LED}
Press # to exit Programming {Solid Red LED}
NOTE: A Door Position Sensor must be installed.
Enable & Set Door Prop Time (Default = Door Prop Disabled)
Enter Programming Mode {Alternating Red & Green LED}
To enable, Press 881 + # {Alternating Red & Green LED}
Press 3 + [01-99 seconds] + # (sets Door Prop Time; Default = 00) {Alternating Red & Green LED}
To disable, Press 880 + # {Alternating Red & Green LED}
Press 300 + # {Alternating Red & Green LED}
Press # to exit Programming {Solid Red LED}
NOTE: A Door Position Sensor must be installed. Relay will remain activated until the door closes OR the Alarm Relay
time expires, whichever occurs first.
Set Shunt Relay Time (Default = Shunt Disabled)
With the Shunt Relay Enabled, the Auxiliary (K3) Relay will activate simultaneously with the Strike Relay:
Enter Programming Mode {Alternating Red & Green LED}
To enable, Press 812 + # {Alternating Red & Green LED}
Press 0 + [01-99 seconds] + # (sets Shunt Relay Time; Default = 01) {Alternating Red & Green LED}
To disable, Press 810 + # {Alternating Red & Green LED}
Press # to exit Programming {Solid Red LED}
NOTE: DIP SWITCH 1 on the E5RM control module, must be ON. Shunt cannot be used if Anti-Duress is enabled.
Set Anti-Duress Relay Time (Default = Anti-Duress Disabled)
With the Anti-Duress Relay Enabled, the Auxiliary (K3) Relay will activate when the Door Open Password (See Factory
Defaults) OR a User’s PIN (Entry Mode 2 ONLY), is entered, followed by a ‘9’:
Enter Programming Mode {Alternating Red & Green LED}
To enable, Press 811 + # {Alternating Red & Green LED}
Press 0 + [01-99 seconds] + # (sets Duress Relay Time; Default = 01) {Alternating Red & Green LED}
To disable, Press 810 + # {Alternating Red & Green LED}
Press # to exit Programming {Solid Red LED}
NOTE: DIP SWITCH 1 on the E5RM control module, must be ON. Anti-Duress cannot be used if Shunt is enabled.
Enable Reader Lockout (Default = Disabled)
Enabling this function will do the following:
1. If an invalid card or card number is used (5) times in a row, this option will “Lockout” the keypad for approx. 1 minute.
2. In Entry Mode 2, if an invalid PIN number is entered over (5) times, the card will automatically be deleted.
Enter Programming Mode {Alternating Red & Green LED}
To enable, Press 851 + # {Alternating Red & Green LED}
To disable, Press 850 + # {Alternating Red & Green LED}
Press # to exit Programming {Solid Red LED}
Set Door Status Sensor Configuration (Default = Normally Open)
Enter Programming Mode {Alternating Red & Green LED}
For Normally Closed, Press 861 + # {Alternating Red & Green LED}
For Normally Open, Press 860 + # {Alternating Red & Green LED}
Press # to exit Programming {Solid Red LED}
P:\INSTALLATION INST\Access Controls\INST-E4KP\INST-E4KP.vsd Rev C 10-09 Page 4

KEYPAD –
MODEL E4KP
CONTROLLER RELAY MODULE –
MODEL E5RM
+12V
GND
CLOCK
DATA
+
-
ACCESS
CONTROLLER
K3 FUNCTION SETTING
FUNCTION
DURESS/SHUNT
GUARD
PATROL
12 3
ON OFF OFF
ON
ON
OFFOFF
OFF OFF
MODEL : E5RM
S/N : 12345678
K3
ALARM
STRIKE
DOOR SENSOR
EXIT BUTTON
INPUT DC12V
ON
123
PROGRAMMING OPTIONS (CONTINUED)
SPECIFICATIONS
Keypad – Model E4KP
Operating Voltage: 10V – 15V DC
Power Consumption: 120mA Max @ 12VDC
Frequency:125KHz
Read Range:Up to 3" (Card, In noise-free environment)
Keyboard:12 Keys (0~9, , #), Membrane Keys
Indicator:Dual Color LED (Green/Red)
Memory (User) Capacity:670 Cardholders
Card Format:HID Compatible 125KHz
Cable Length:1 Ft.
Dimensions:3" W x 4-3/8" H x 0.9" D (75 x 112 x 23 mm)
Weight:8.5 ounces
Operating Temperature:32
o
F – 122
o
F (0
o
C – 50
o
C)
Humidity:30% ~ 95% (Non-condensing)
Controller Relay Module – Model E5RM
Operating Voltage: 10V – 15V DC
Power Consumption: 300mA Max @ 12VDC (with E4KP)
Relay:Strike: 5A N.O. / 3A N.C. @ 30VDC
Alarm/Aux.: 1A @ 30VDC
Inputs:Exit Button (N.O.)
Door Status Sensor (N.O. or N.C)
Dimensions:1-3/4" W x 2-5/8" L x 0.9" D (46 x 66 x 21 mm)
Weight:2.5 ounces
Operating Temperature:32
o
F – 122
o
F (0
o
C – 50
o
C)
Humidity:30% ~ 95% (Non-condensing)
*
Change Default Passwords
Enter Programming Mode {Alternating Red & Green LED}
To change System Setup Password (Default = 111111),
Press + New 6-digit Password + # {Alternating Red & Green LED}
To change Door Open Password (Default = 1234),
Press + New 4-digit Password + # {Alternating Red & Green LED}
To change Patrol Password (Default = 1234567)
Press + New 7-digit Password + # {Alternating Red & Green LED}
Press # to exit Programming {Solid Red LED}
Enable Patrol Function (Default = Patrol Function Disabled)
With this feature enabled, entering the Patrol Password will send a 1 second pulse on the Auxiliary (K3) Relay:
Enter Programming Mode {Alternating Red & Green LED}
Press 831 + # (enables Patrol Function, use 830 + #) {Alternating Red & Green LED}
Press # to exit Programming {Solid Red LED}
NOTE: DIP SWITCH 3 on the E5RM control module, must be ON.
*
*
*
P:\INSTALLATION INST\Access Controls\INST-E4KP\INST-E4KP.vsd Rev C 10-09 Page 5
Change a User’s PIN (Entry Mode 2 Only)
Press + 2 + # + Present Card OR (Enter Card Number + #) {Flashing Red LED}
Enter old 4-digit PIN + # {Flashing Red LED}
Enter new 4-digit PIN + # {Solid Red LED}
NOTE: It is NOT required to enter Programming Mode to change a PIN.
Clear Memory / Reset to Default Settings
Enter Programming Mode {Alternating Red & Green LED}
Press 99999999 + # {Green LED will flash rapidly, then Alternating Red & Green LED}
Press # to exit Programming {Solid Red LED}
*

(+) (-)
12VR
MODULE
POWER
SUPPLY
24VDC
(+) (-)
12V 24V
600 SERIES
POWER SUPPLY
WITH
12VR MODULE
(+)
+12V
GND
CLOCK
DATA
RED
BLK
BRN
ORG
RED
BLK
BRN
ORG
J3
RED
BLK
BRN
ORG
E4KP
KEYPAD
YEL
E5RM
CONTROLLER RELAY MODULE
NOT
USED
RED
BLK
BRN
ORG
YEL
GRN
BLU
YEL
GRN
BLU
YEL
GRN
BLU
+
-
12 VDC
LOCK
OUTPUT
ALARM
OUTPUT
AUX. OUTPUT
(DIP SW SELECTABLE)
C
NC
NO
C
NC
NO
C
NC
NO
Request -to-Exit
Door Status
J2
J1
RED
BLK
BRN
ORG
YEL
GRN
BLU
YEL
GRN
BLU
YEL
GRN
BLU
(+)
REX BUTTON
N.O. DRY CONTACT
(OPTIONAL)
DOOR STATUS
SWITCH
N.O. OR N.C.
(OPTIONAL)
TYPICAL WIRING DIAGRAM
Installation Notes:
1. Max distance between the E4KP Keypad & E5RM is 300ft.
2. Alarm Output Relay will be used for Door Prop or Forced Door Alarm.
3. Auxiliary Output Relay will be used for Shunt/Anti-Duress feature and/or Patrol Function.
4. J1, J2, & J3 Connectors are included with the E5RM. Power Supply, Exit Button, & Door Switch are sold separately.
P:\INSTALLATION INST\Access Controls\INST-E4KP\INST-E4KP.vsd Rev C 10-09 Page 6
5. For DC voltage electric strikes and electric bolt locks, install a Metal Oxide Varistor (MOV) as close to the coil as possible to
prevent kickback voltage from damaging the relay module. Consult with the Lock Manufacturer to see if a voltage suppression
device is necessary.
300 ft MAX
FAIL
SECURE
LOCK
+
-
MOV
FAIL
SAFE
LOCK
+
-
MOV
Keypad
Power
12VDC ONLY
12V or 24VDC
(-)
Lock
Power
(-)
Keypad
Power
Lock
Power
(+)
OR
USE WITH
24vdc LOCKS
*
KEYPAD POWER IS 12V DC ONLY.
CONNECTING A HIGHER VOLTAGE OR AC
WILL DAMAGE THE UNIT AND VOID THE
WARRANTY
*
(+)
(-)
(-)
POWER
SUPPLY
12VDC
(+) (-)
12V
Keypad
Power
Lock
Power
600 SERIES
POWER SUPPLY
USE WITH
12vdc LOCKS
NOTE:
Dual voltage power supplies should be
switched to 12VDC prior to hook-up
Table of contents
Other SDC IP Access Controllers manuals

SDC
SDC EntryCheck 920 User manual

SDC
SDC EntryCheck 936 User manual

SDC
SDC 923PW EntryCheck User manual

SDC
SDC 950 ENTRYCHECK Installation manual

SDC
SDC 920P EntryCheck User manual

SDC
SDC IP100SGK-EM User manual

SDC
SDC EntryCheck 920PW User manual

SDC
SDC EntryCheck 931-KP-4U User manual

SDC
SDC IP100HK User manual

SDC
SDC 950 ENTRYCHECK Installation manual