0020135485_02 Operating instructions 7
3.2 Control function
The control controls the Vaillant heating installation and do-
mestic hot water generation of a connected domestic hot wa-
ter cylinder.
If the control is installed in a living room, you can operate the
heating installation and domestic hot water generation from a
living room.
3.2.1 Heating installation
The controller is a room-temperature-controlled controller
and must be installed in the living room. You can use the
controller to set the desired temperature for different times
of the day and for different days of the week. The temperat-
ure sensor measures the room temperature and sends the
values to the controller. At lower room temperatures, the con-
troller switches the heater on. Once the room temperature
reaches the desired set temperature, the controller switches
the heater off. The controller therefore reacts to the fluctu-
ations of the room temperature and constantly controls the
room temperature to the temperature that you have set.
Data exchange and power supply on the controller are via
an eBUS interface. The controller can be equipped with the
Vaillant diagnosis software and the Vaillant Internet commu-
nication system for remote diagnosis and remote settings.
3.2.2 Domestic hot water generation
You can use the control to set the temperature and time for
domestic hot water generation. The heat generator heats the
water in the domestic hot water cylinder until it reaches the
set temperature. You can set a time period during which hot
water should be available in the domestic hot water cylinder.
3.2.3 VR 66 Control Centre
If a VR 66 Control Centre is connected, you can control two
independent heating circuits with just one VRT 350 control-
ler; e.g. one heating circuit is in the single-occupancy house
and the second heating circuit is in a guest apartment in
this building. In this case, one controller is always the main
controller (Zone 1) and the other controller is the auxiliary
controller (Zone 2). For Zone 1, which is controlled via the
main controller, all of the functions are available to you. For
Zone 2, you can use the auxiliary controller to set the desired
temperature for different times of the day and different days
of the week.
3.3 Frost protection function
The frost protection function protects the heating system and
apartment from frost damage.
The frost protection function monitors the room temperature.
If the room temperature
–falls below 5 °C, the controller switches the heater on and
controls the system to a target room temperature of 5 °C.
–exceeds 5 °C, the heater is switched off but the room
temperature monitoring remains active.