manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Valcom
  6. •
  7. Power Supply
  8. •
  9. Valcom VP-4024C User manual

Valcom VP-4024C User manual

24VDC/4 AMP LINEAR POWER SUPPLY
VP-4024C
TECHNICAL
SPECIFICATIONS
5614 Hollins Road Roanoke, Virginia 24019 Phone: 540-563-2000 Fax: 540-362-9800
E-Mail: [email protected] www.valcom.com
SPECIFICATIONS:
FEATURES:
24 VOLT DC "A" BATTERY POWER SUPPLY
REGULATED AND FILTERED
FLOATING OUTPUT
TWO FUSED OUTPUTS, 2 AMPS EACH
INPUT FUSE PROTECTION
OUTPUT OVERVOLTAGE PROTECTION
CURRENT LIMITING
WALL MOUNTING PLATE INCLUDED
PROVIDES 80 VALCOM POWER UNITS
DESCRIPTION:
Wall mountable, linear, 24 Vdc, filtered "A" Talk Battery power supply with two fused 2 Amp
outputs.
INPUT
Voltage/Frequency 105 - 120 Vac, 60 Hz
Power 150 Watts
BTU/Hr 515BTU/Hr
Protection 2A/125 Vac Input Fuse
Connection ACCord
OUTPUT
Voltage 24Vdc Regulated+10%
Filtered,Floating
10 mV Ripple Maximum
Current 4Amp(2Aperoutput)
Protection Over-VoltageProtection
CurrentLimiting
Connections WireCage Connectors
REGULATORY
UL, cUL Listed
ENVIRONMENT
Temperature 32 - 122 °F (0 - 50 °C)
Humidity 10-90% Non-condensing
MOUNTING
WallMounted
MountingPlateHardware Included
DIMENSIONS AND WEIGHT
10.70“ (27.18 cm) H x 6.35“ (16.13 cm) W x
3.75“(9.53 cm) D
Weight:13.00 lbs (5.85kg)
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL VP-4024C
24 VDC/4 AMP LINEAR POWER SUPPLY
The 24 Vdc, 4 Amp Power Supply, Model VP-4024C, shall be wall mount, regulated and filtered, "A" battery type power
supply with two 2 Amp outputs. The unit shall be solid state and provide over voltage protection and LED indication of of
overload. The unit shall provide a three conductor grounded power cord with NEMA 5-15P type plug for AC input connection
and wire cage connectors for all output connections. The input shall be circuit breaker protected. The unit shall be UL and
cUL Listed.
The power supply shall provide a floating 24 Vdc output. The chassis shall be AC grounded and a LOC GND terminal,
connected to AC GND, shall be provided for output reference. Output voltage shall be -24 Vdc +10%. Output current shall
be 4 Amps. Maximum ripple at rated output shall be 10 mV RMS. Output shall be current limiting and provide over-voltage
protection. Input voltage shall be 105 - 120 Vac, 60 Hz, 150 watts maximum. Input fuse shall be rated at 2Amps/125 Vac.
Operatingtemperature shallbe +32to104 °F(0to 40 °C). Operatinghumidity shallbe 0to90% non-condensing.
The housing shall be constructed of gray painted 16 gauge steel. The wall mounting plate and mounting hardware shall be
included.
Maximum dimensions shall be 10.70“ (27.18 cm) H x 6.35“ (16.13 cm) W x 3.75“ (9.53 cm) D. Shipping weight shall be
13.00 lbs (5.85kg).
Limited Warranty
Valcom, Inc. warrants its products to be free from defects in materials and workmanship under conditions of
normal use and service for a period of one year from the date of shipment. The obligation under this warranty shall be limited to
the replacement, repair or refund of any such defective device within the warranty period, provided that:
1. inspection by Valcom, Inc. indicates the validity of the claim,
2. the defect is not the result of damage, misuse, or negligence after the original shipment,
3. the product has not been in any way repaired by others and that factory sealed units are unopened.
(A service charge plus parts and labor will be applied to units defaced or physically damaged).
4. freight charges for the return of products to Valcom, Inc. are prepaid,
5. all units “out of warranty” are subject to a service charge. The service charge will cover minor repairs
(major repairs will be subject to additional charges for parts and labor).
This warranty is in lieu of and excludes all other warranties expressed or implied, and in no event shall
Valcom, Inc. be liable for any anticipated profits, consequential damages, loss of time or other losses incurred by the buyer in
connection with the purchase, operation or use of the product.
This warranty specifically excludes damage incurred in shipment. In the event a product is received in damaged condition,
the carrier should be notified immediately. Claims for such damage should be filed with the carrier involved in accordance with the
F.O.B. point.
5614 Hollins Road Roanoke, Virginia 24019 Phone: 540-563-2000 Fax: 540-362-9800
E-Mail: [email protected] www.valcom.com

Other Valcom Power Supply manuals

Valcom VP-324 User manual

Valcom

Valcom VP-324 User manual

Valcom VP-2124A User manual

Valcom

Valcom VP-2124A User manual

Valcom VP-12124 User manual

Valcom

Valcom VP-12124 User manual

Valcom VP-12124 User manual

Valcom

Valcom VP-12124 User manual

Valcom VP-624D User manual

Valcom

Valcom VP-624D User manual

Valcom VP-412A User manual

Valcom

Valcom VP-412A User manual

Valcom VP-412A User manual

Valcom

Valcom VP-412A User manual

Valcom VP-6124 User manual

Valcom

Valcom VP-6124 User manual

Valcom VP-1124A User manual

Valcom

Valcom VP-1124A User manual

Valcom VIP-814A User manual

Valcom

Valcom VIP-814A User manual

Valcom VP-1124 User manual

Valcom

Valcom VP-1124 User manual

Valcom VP-1124 User manual

Valcom

Valcom VP-1124 User manual

Valcom VP-4124 User manual

Valcom

Valcom VP-4124 User manual

Valcom VP-6124-P User manual

Valcom

Valcom VP-6124-P User manual

Valcom VP-324 User manual

Valcom

Valcom VP-324 User manual

Valcom VP-2024 User manual

Valcom

Valcom VP-2024 User manual

Valcom VP-4024C User manual

Valcom

Valcom VP-4024C User manual

Valcom VP-4124D User manual

Valcom

Valcom VP-4124D User manual

Valcom VP-2048C User manual

Valcom

Valcom VP-2048C User manual

Valcom VP-6124 User manual

Valcom

Valcom VP-6124 User manual

Valcom VP-4124 User manual

Valcom

Valcom VP-4124 User manual

Valcom V-C6124P User manual

Valcom

Valcom V-C6124P User manual

Valcom VP-2124A User manual

Valcom

Valcom VP-2124A User manual

Valcom VP-2048C User manual

Valcom

Valcom VP-2048C User manual

Popular Power Supply manuals by other brands

Enterasys C2RPS-SYS installation guide

Enterasys

Enterasys C2RPS-SYS installation guide

Pulsar PSD480250 manual

Pulsar

Pulsar PSD480250 manual

SilverStone ST55F-G manual

SilverStone

SilverStone ST55F-G manual

Speedotron 1005 instruction manual

Speedotron

Speedotron 1005 instruction manual

Siemens FP120-Z1 Technical manual

Siemens

Siemens FP120-Z1 Technical manual

Phoenix Mecano wiener PL508 Service manual

Phoenix Mecano

Phoenix Mecano wiener PL508 Service manual

Amada DC25 Operation manual

Amada

Amada DC25 Operation manual

Zeliox ECO user manual

Zeliox

Zeliox ECO user manual

Antec NEO ECO 620C user manual

Antec

Antec NEO ECO 620C user manual

Dometic SMP 301-01 Installation and operating manual

Dometic

Dometic SMP 301-01 Installation and operating manual

Matsusada DJOPF Series manual

Matsusada

Matsusada DJOPF Series manual

Elektro-Automatik EA-PS 10000 3U manual

Elektro-Automatik

Elektro-Automatik EA-PS 10000 3U manual

Tunstall 77 3410 00 installation instructions

Tunstall

Tunstall 77 3410 00 installation instructions

Clarion CAA-188-200 installation instructions

Clarion

Clarion CAA-188-200 installation instructions

Tescom NEOLINE PRO RT user manual

Tescom

Tescom NEOLINE PRO RT user manual

Pulsar PSDC08128 manual

Pulsar

Pulsar PSDC08128 manual

Innovative Technology ICT22012-100 instruction manual

Innovative Technology

Innovative Technology ICT22012-100 instruction manual

Novus FTR instruction manual

Novus

Novus FTR instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.