MOBILE PROBLAST-I-09/14 Page 1
MOBILE PROBLAST
PACKING LIST
1 - Mobile Problast
1 - Instructions
1 - Additional Quick Disconnect
INSTALLATION & OPERATION
1. Unscrew cap on media storage tank
2. Fill abrasive storage tank to ll line with aluminum oxide micron size specied on tank label. The tank
will hold up to 4 lbs of media. DO NOT OVER FILL as clogging may result.
Part No. Nozzle Size, Inches (mm) Color Recommended Media
Long Lasting Crystal Tips (2 per package)
97902 Medium, .032” (.8mm) Blue 25/50 μm Al2O3
97903 Large, .048” (1.2mm) Black 50/100 μm Al2O3, 50 μm Glass
97904 Extra Large, .065” (1.6mm) Red 100-250 μm Al2O3, 50/100 μm Glass
Precision Tungsten Carbide Tips (1 per package)
97905 Small, .026” (.65mm) Yellow 25 μm Al2O3
97906 Medium, .036”(.91mm) Green 50/100 μm Al2O3, 50 μm Glass
97907 Large, .059” (1.5mm) Violet 100-250 μm Al2O3, 50/100 μm Glass
3. Wipe off excess abrasive and screw cap securely back into place. Do not over-tighten; lid will self
seal when under pressure.
4. Attach your 1/4” ID (inside diameter) hose air supply line to the barbed tting on the back of the unit, on
the right of the small valve. Secure hose with a small screw-type clamp. If necessary remove the tting
and replace with the quick disconnect tting. NEVER depressurize the system by disconnecting the
air supply line while under pressure; abrasive will be forced into the foot valve and regulator, causing
damage. Before disconnecting the air supply line, turn regulator down (counterclockwise) until the
pressure gauge reads zero.
**For more help visit: www.vaniman.com/air-supply-connections-blasters/**
5. Regulate air pressure by turning the air regulator knob. Pull knob up to unlock before turning. Pressure
will indicate pressure reading. DO NOT adjust above 100 psi (7 BARS).
6. Use the foot pedal to start the ow of air and blasting media. Release the foot pedal to stop the ow.