Parts List
Assembly Instructions
1. Table Top (Small); 2. Table Top (Big)
3. Release Handle; 4. 1/4 -20 Bolt &Nut!1 each"
5. Top Bracket Tube I 7. Top Bracket Tube II
8. Bracket Connecting piece; 9. Fixed Knob
10. Bolt Sleeve; 11. Bolt Plate; 12. 3/8 -18UNF Bolt;
13. 1/4 -20 Bolt!black"; 14. 1/4 -10 Bolt!white";
15. Drawn Pipe ;16. Spacer; 17. Column Assembly;
18. Washer; 19. Triangle Knob;
20. Stand Pipe Stopper.; 21. Stand pipe. 22. Base
23. Caster with Lock!2 each";
24. Caster without Lock!2 each"
1. Table Top (Small)
2. Table Top (Large)
3. Release Handle
4. 1/4" #20 Bolt & Nut (1 Each)
5. Top Bracket Tube 1
6. Top Bracket Tube II
7. Bracket Connecting Piece
8. Fixed Knob
9. Draw Pipe
10. Bolt Sleeve
11. Bolt Plate
12. 3/8" #18 UNF Bolt
13. 1/4" #20 Bolt (Black)
14. 1/4" #10 Bolt (Chrome)
15. Spacer
16. Column Assembly
17. Spacer
18. Triangle Knob
19. Stand Pipe Stopper
20. Stand Pipe
21. Base
22. Caster With Lock (2)
23. Caster Without Lock (2)
24 Outer Tube
2. Place Trip Lever (3) with its curved side facing upwards on
Column Assembly (16). Ensure the Trip Lever sits on top of the
Trip Rod that is within the column. Secure with Bolt and Nut (4)
See Fig. 2.
1.Remove contents from packaging. Lay Top Boards (1 & 2)
upside down on flat surface with Mounting Tubes (5 & 6) facing
upward. See Fig. 1. Set aside for use at Step 3.
3.Remove Triangle Knob (18), Spacer (17) and the Inner Tube (9)
from the Outer tube (24). See Fig. 3.
4. Insert Outer Tube (24) ofthe Column Assembly through
Mounting Tube (5) of the Short Top Board from Step 1.Then
insert Outer Tube through the Mounting Tube (6) on the
Large Table Top (2). Insert Inner Tube (9) through Mounting
Tube (6). Tighten Fixed Knob (18) and Spacer (17) into the
“Hole” on Outer Tube (24). See Fig. 4.
FIG. 1
1
2
56
FIG. 3
16
17
18
Indent 24
Page 1
Item #: M881N-STCR-YYVM
Important Warnings
Please follow all instructions and warnings to avoid hazardous
situations that can result in property damage and/or patient/
resident/staff/caregiver injury and/or death.
Inspect the product for damage and loose hardware before each
use. DO NOT use the product if it appears to be damaged or
unstable and DO NOT modify the product in any way.
Assembly Precautions
This Overbed Table utilizes a high-tension spring loaded
mechanism to raise the table. DO NOT remove #13 Black
Screw and replace with the #14 Chrome Screw until table is
fully assembled. The table top will raise suddenly and cause
serious personal injury. DO NOT over tighten bolts, screws or
use power tools when assembling this product.
Deluxe Tilt-Top Overbed Table
FIG. 4
9
IMPORTANT NOTE!!!
It is normal to hear clanking
sounds when shaking or moving
the Column Assembly (16). This is
due to the movement of the trip
rod within the column. During
transport, sometimes the trip rod
may fall out of the column
assembly. Simply re-insert the trip
rod back into the column before
proceeding to the next step.
(Reminder: DO NOT remove #13
Black Screw from the column)
Ref no: M881N-STCR-YYVM Manual V3031518
6. Install two Bolt Sleeves (10) into the upside down Base (21)
and then position the two Bolts (12) through the Bolt Plate
(11) and into the Bolt Sleeves (10). Position the Base (21)
over the Column Assembly (16) and thread bolts into bottom
of Column Assembly (16) and tighten using 16mm wrench.
See Fig. 6.
7. Turn the table upright and stand on Casters.
8. CAUTION:
This step must be completed last to prevent damage to the
spring loaded mechanism. With one hand pressing down on the
table top to prevent table top from springing upwards, gently
remove Black Screw (13) in the Column Assembly labeled
“Remove After Assembly.” and replace it with Chrome
Screw (14) provided in the hardware package. (Note: Table top
must be pressed down the entire time until chrome screw is
tighten securely.) The bottom chrome screw with the "Do Not
Remove" label should never be removed as it will damage the unit
and void your warranty. See Fig.7 and Fig 8.
1. This is a one-touch height adjustment table. For the
convenience of our user, this table has been specially
designed to allow user to raise the table top to desired
height by simply applying light pressure upwards at any point
under the table. The user will not be required to turn any
knob to adjust the table upwards.
2. To lower the table, squeeze Trip Lever (3) up towards top
and push down at column to desired height. Do not put
pressure on Tabletop end that is opposite the column.
Column Assembly will lock upon release of Trip Lever.
3. To tilt, turn Triangle Knob (18) counter-clockwise to loosen.
Set to desired angle and then turn knob (18) clockwise to
tighten.Short Table (1) top does not tilt.
FIG. 7
Remove 13
Insert 14
FIG. 8
mbly Precaut
Intended Use
This product is designed for use as a movable patient/resident
table top surface for reading, eating, or keeping small personal
items such as glasses, telephone or books, within easy reach. This
product is designed for indoor use ONLY and within close
proximity of skilled caregivers. It is not designed to hold
electrical items (such as televisions, computer monitors, coffee
pots, etc.) and should not be used near open flames and
excessive heat.
Maximum weight limitation for this product is 50 lbs. (22 kg.);
weight should be evenly distributed over the table top surface
while at the lowest usable height to help maintain a stable
condition.
DO NOT overload this product, as that could result in
breakage, as well as damage to property and/or serious injury.
Use ONLY as directed for its intended use.This product
SHOULD NOT be used as a sleep surface, walker, mobility aid;
or to assist a person in walking, sitting down, standing up; or to
prevent or brace a person’s fall; or to help transport persons or
items.
Operating Instructions
10101 Stafford Centre Drive Suite B
Stafford Texas 77479
Tel: 832-939-8290
www.vaunn.com
Made in China
One Year Warranty
This warranty is solely for the benefit of the original consumer
purchaser.
This device was built to exacting standards and carefully
inspected prior to shipment.Your Vaunn® Medical product is
warranted to be free of defects in materials and workmanship
for a period of one year. If within such warranty period, the
product proves defective, the product will be repaired or
replaced, at the option of Vaunn® Medical.This warranty does
not cover device failure due to owner misuse or negligence,
or normal wear and tear. If you have a question about your
Vaunn® Medical product or this warranty, please contact us.
5.
5.Install the two Casters With Lock (22) into the side of the
Base (21) which connects to Column Assembly (16). Install
two Non-Locking Casters (23) into the opposite side of the
Base (21). See Fig. 5.
22
LOCK (22)
23
FIG. 5
Column end of base
with 2 holes 21
12
11 10
Ref no: M881N-STCR-YYVM Manual V3031518

Other manuals for M881N-STCR-YYVM

1

Other Vaunn Medical Medical Equipment manuals

Vaunn Medical M880N-IVGY-YYVM User manual

Vaunn Medical

Vaunn Medical M880N-IVGY-YYVM User manual

Vaunn Medical M881N-SICR-YYVM User manual

Vaunn Medical

Vaunn Medical M881N-SICR-YYVM User manual

Vaunn Medical M725N-DLWH-CHVM User manual

Vaunn Medical

Vaunn Medical M725N-DLWH-CHVM User manual

Vaunn Medical M881N-STCR-YYVM User manual

Vaunn Medical

Vaunn Medical M881N-STCR-YYVM User manual

Popular Medical Equipment manuals by other brands

aidapt Quiet Knight Mattress Stopper Fixing and maintenance instructions

aidapt

aidapt Quiet Knight Mattress Stopper Fixing and maintenance instructions

Bauerfeind ValguLoc user manual

Bauerfeind

Bauerfeind ValguLoc user manual

NSK Primado2 Operation manual

NSK

NSK Primado2 Operation manual

OmniPod 5 Technical user guide

OmniPod

OmniPod 5 Technical user guide

Konica Minolta REGIUS 190 Service manual

Konica Minolta

Konica Minolta REGIUS 190 Service manual

Atos Provox FreeHands FlexiVoice quick start guide

Atos

Atos Provox FreeHands FlexiVoice quick start guide

BioTel Care BGM user manual

BioTel Care

BioTel Care BGM user manual

Medutek KATASPIR 230/12BR instruction manual

Medutek

Medutek KATASPIR 230/12BR instruction manual

sensiplast 300418 Instructions for use

sensiplast

sensiplast 300418 Instructions for use

Caremax R-C4C instruction manual

Caremax

Caremax R-C4C instruction manual

Nox Medical A1 manual

Nox Medical

Nox Medical A1 manual

Boston Scientific WaveWriter Alpha Series Directions for use

Boston Scientific

Boston Scientific WaveWriter Alpha Series Directions for use

Seca 531 instructions

Seca

Seca 531 instructions

March PX-500 user guide

March

March PX-500 user guide

Ossur i-limb User quick reference guide

Ossur

Ossur i-limb User quick reference guide

CMF OL1000 manual

CMF

CMF OL1000 manual

EDAN INSTRUMENTS SE-2003 Series user manual

EDAN INSTRUMENTS

EDAN INSTRUMENTS SE-2003 Series user manual

Zeiss EXTARO 300 Instructions for use

Zeiss

Zeiss EXTARO 300 Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.