Venmar DECO-TOUCH WALL CONTROL Instruction Manual

DECO-TOUCH WALL CONTROL INSTALLATION AND OWNER GUIDE
THIS WALL CONTROL MAY BE USED WITH THE FOLLOWING VENTILATION UNITS:
VENMAR UNITS VÄNEE UNITS
• AVS SOLO • AVS KUBIX HRV PLUS AND ERV • GOLD SERIES • HE*
• AVS DUO • HE • VIGÖR HRV PLUS • NOVO+
• COMPACT • NOVOFIT • VIGÖR ERV • 60H*
• HRV AND ERV EKO 1.5 • HRV CONSTRUCTO 1.5V*, 1.5ES AND 2.0ES • HRV AND ERV 90H-V ECM • 100H
• ERV CONSTRUCTO 2.0ES • CONSTRUCTO 1.0* • 90H-V* • 200H
ITIS RECOMMENDED TO WEAR SAFETY GLASSES AND GLOVES WHILE PERFORMING THESE INSTRUCTIONS.ALWAYS DISCONNECT THE UNIT BEFORE MAKING ANY CONNECTIONS.
FAILURE TO DISCONNECT POWER COULD RESULT IN ELECTRIC SHOCK OR DAMAGE TO THE WALL CONTROL OR ELECTRONIC MODULE INSIDE THE UNIT.
WARNING
!
FAILURE TO COMPLY WITH THE FOLLOWING CAN CAUSE ERRATIC OPERATION OF THE UNIT AND/OR THE WALL CONTROL:
• NEVER INSTALL MORE THAN ONE MAIN WALL CONTROL PER VENTILATION UNIT;
• KEEP CONTROL LOW VOLTAGE WIRING AT LEAST 1 FOOT (305 MM) AWAY FROM MOTORS, LIGHTING BALLAST, LIGHT DIMMING CIRCUIT AND POWER DISTRIBUTION
PANEL. DONOT ROUTE CONTROL WIRING ALONGSIDE HOUSE POWER WIRING;
• ENSURE THE WIRES ARE SECURELY CONNECTED.
CAUTION
UNPLUG THE VENTILATION UNIT FROM POWER SOURCE.
CUT A2 7/8” X1 3/8” HOLE IN AWALL, AT A
CONVENIENT LOCATION FOR THE WALL CONTROL.
ROUTE THE CABLE FROM THE UNIT TO THIS
HOLE.
NOTE: DIMENSIONS SHOWN ARE FOR AN INSTALLATION
WITHOUT WALL BOX.
TEMPORARILY PLACE THE SWITCH OVER THE HOLE
AND MARK BOTH MOUNTING SCREW HOLE POSITIONS.
REMOVE THE SWITCH, DRILL BOTH SCREW HOLES
(3/16” Ø) IN WALL AND INSERT WALL ANCHORS
(INCLUDED).
VC0116A
Ø 3/16”, typ.
STRIP THE END OF THE CABLE TO ACCESS
THE 4 WIRES. STRIP THE END OF EACH WIRE.
USING ASMALL BLADE SCREWDRIVER, CONNECT
EACH WIRE TO ITS CORRESPONDING TERMINAL, ON
THE BACK OF THE WALL CONTROL: YELLOW WIRE
TO “Y”, RED WIRE TO “R”, GREEN WIRE TO “G” AND
BLACK WIRE TO “B”.
MOUNT THE WALL CONTROL TO THE WALL. PLUG THE
VENTILATION UNIT AND TEST THE WALL CONTROL
OPERATION.
Y
B
G
R
VE0243
VC0115
*CONSTRUCTO 1.0 AND VÄNEE 60H BUILT IN AUGUST 2008 AND LATER, VÄNEE HE BUILT IN JULY 2006 AND LATER AND CONSTRUCTO 1.5V AND VÄNEE 90H-V BUILT IN NOVEMBER
2012 AND LATER. THE DATE CODE ON THE UNIT IS PA RT OF ITS 13-DIGIT SERIAL NUMBER. FOR EXAMPLE, THE SERIAL NUMBER XXXX0708XXXXX, WHERE 07 IS THE YEAR AND 08 THE
MONTH (AUGUST), THE DATE CODE IS ALWAYS THE FIFTH, SIXTH, SEVENTH AND EIGHTH DIGITS.
WALL CONTROL INSTALLATION
WALL CONTROL USE
BACKLIGHT
IFTHE BACKLIGHT IS NOT ILLUMINATED, THE FIRST BUTTON PRESSED (NO MATTER WHICH
BUTTON) SHALL TURN ON THE BACKLIGHT. THE BACKLIGHT REMAINS ILLUMINATED FOR
10 SECONDS AFTER THE LAST BUTTON PRESSED.
OPERATING MODES


OR
TOCHANGE THE OPERATION MODES OF THE VENTILATION UNIT, PRESS THE
UP OR DOWN ARROW BUTTON. OPERATING MODE LABEL WILL THEN SCROLL
UP OR DOWN ON LCD SCREEN.
OFF
PUT THE UIT ON STAND-BY MODE, SO IT WILL ONLY RESPOND TO OVERRIDE
WALL CONTROLS (IF PRESENT). ONLCD SCREEN, ONLY THE HOUSE IS
VISIBLE SHOWING THE CONTROL IS POWERED ON. THIS IS THE FACTORY
DEFAULT MODE.
RECIRC
AIR IS RECIRCULATED INSIDE THE HOUSE AT HIGH SPEED.
NOTE: THIS MODE IS NOT AVAILABLE WITH THE FOLLOWING UNITS:
HRV CONSTRUCTO 1.5V, 1.5ES, 2.0ES,
ERV CONSTRUCTO 2.0ES AND VÄNEE 100H, 200H, 90H-V.
OPERATING MODES (CONT’D)
20 MIN/H
THE VENTILATION UNIT EXCHANGES AIR INTERMITTENTLY ON AONE
HOUR CYCLE AS FOLLOWS: OFF FOR 40 MIN. (OR RECIRCULATION*
ON HIGH SPEED FOR 40 MIN., SEE NEXT SECTION ON BACK PAGE) AND THEN
EXCHANGE AIR DURING 20 MIN. ON LOW SPEED. REPEAT CYCLE AFTER THE
20 MIN. OF AIR EXCHANGE.
*EXCEPT FOR HRV CONSTRUCTO 1.5V, 1.5ES, 2.0ES,
ERV CONSTRUCTO 2.0ES AND VÄNEE 100H, 200H AND 90H-V UNITS.
MIN
AIR IS EXCHANGED WITH THE OUTSIDE ON LOW SPEED.
MAX
AIR IS EXCHANGED WITH THE OUTSIDE ON HIGH SPEED.
09947 REV. 04
WALL CONTROL USE (CONT’D)
HOW TO SET THE RELATIVE HUMIDITY (RH) LEVEL AND CHOOSE
BETWEEN OFF IN STAND BY OR RECIRCULATION IN STAND BY*
SETTING THE RELATIVE HUMIDITY LEVEL ALLOWS TO SELECT THE MAXIMUM DESIRED INDOOR
HUMIDITY LEVEL (IN PERCENTAGE). THIS VALUE WILL BE USED TO START THE DEHUMIDISTAT
OVERRIDE (AIR EXCHANGE ON HIGH SPEED).
¹OFF IN STANDBY*: ON20 MIN/HMODE, THE VENTILATION UNIT IS OFF DURING 40 MINUTES
AND EXCHANGES AIR WITH THE OUTSIDE ON LOW SPEED DURING THE
REMAINING 20 MINUTES OF THE HOUR; THIS IS THE DEFAULT VALUE.
*OFF IN STANDBY AND RECIRCULATION IN STANDBY ARE NOT AVAILABLE FOR
HRV CONSTRUCTO 1.5V, 1.5ES, 2.0ES, ERV CONSTRUCTO 2.0ES AND VÄNEE 100H,
200H AND 90H-V UNITS.
DEHUMIDISTAT OVERRIDE SELECTION
INTHE OPERATING MODES MIN, MAX, 20 MIN/HAND RECIRC (IF AVAILABLE), THE
USER CAN SELECT ADEHUMIDISTAT OVERRIDE SO THAT IF THE RELATIVE HUMIDITY (RH) IN
THE HOUSE EXCEEDS THE RH SETTING PREVIOUSLY STORED, THE VENTILATION UNIT WILL
EXCHANGE IN HIGH SPEED UNTIL THE TARGET INDOOR RH SETTING IS REACHED.
ANAIR EXCHANGER IS NOT ADEHUMIDIFIER, BUT IT CAN CHANGE THE INDOOR RELATIVE HUMIDITY
BY BRINGING IN DRIER OR MORE HUMID AIR FROM OUTSIDE DURING NON HEATING SEASON. THE
DEHUMIDISTAT OVERRIDE FUNCTION IS USEFUL TO REDUCE INDOOR RH WHEN THE OUTDOOR
AIR IS COOL AND DRY DURING THE HEATING SEASON. SELECT ATARGET RH BETWEEN 30%
AND 55% ACCORDING TO YOUR COMFORT. WHEN OUTDOOR RELATIVE HUMIDITY IS HIGH (E.G.
IN SUMMER), TURN OFF THE OVERRIDE BY PRESSING OK UNTIL THE RH DISPLAY DISAPPEARS.
WHEN THE DEHUMIDISTAT OVERRIDE IS ACTIVATED, THE AUTO INDICATOR
WILL APPEAR ON LCD SCREEN TO SHOW THAT THE ACTUAL MODE IS BEING
OVERRIDDEN. ALSO, THE RELATIVE HUMIDITY APPEARS (IF IT WAS NOT SHOWN,
SEE EXAMPLE BESIDE). ONCE THE TARGET HUMIDITY LEVEL IS REACHED, THE
UNIT GOES BACK INTO ITS ORIGINAL OPEARTING MODE AND AUTO DISAPPEARS
FROM LCD SCREEN.
NOTE: IF THE ACTUAL MODE IS MAX, ONLY THE RELATIVE HUMIDITY LEVEL APPEARS ON
SCREEN, AUTO LABEL WILLL NOT APPEAR.
TOENGAGE THE HUMIDITY OVERRIDE, PRESS OK.THE ACTUAL INDOOR RH AND THE %HUM
LABEL APPEAR ON LCD SCREEN.
NOTE: IFTHE ACTUAL RH IS LESS THAN 20%, THEN THE HUMIDITY INDICATOR WILL
DISPLAY “LO”, AND IF THE ACTUAL RH IS GREATER THAN 80%, THEN THE HUMIDITY
INDICATOR WILL DISPLAY “HI”.
TOTURN OFF THE DEHUMIDISTAT OVERRIDE, PRESS OK AGAIN. THE RH AND %HUM
DISPLAY WILL DISAPPEAR FROM LCD SCREEN.
AFTER APOWER FAILURE, THE WALL CONTROL RETURNS TO ITS ORIGINAL OPERATION MODE.
ALL SETTINGS ARE KEPT IN MEMORY.

3 sec. PRESS AND HOLD OK FOR 3 SEC. TO ACCESS
THE SETTING MENU. THE BACKLIGHT WILL BE
ACTIVATED DURING ALL THE PROCEDURE.
THE RELATIVE HUNMIDITY ARROW AND
VALUE WILL FLASH
(DEFAULT SETTING: 45%).
OR



USE UP OR DOWN ARROW TO
CHANGE THE VALUE. THE VALUE
CHANGES BY 1% INCREMENTS.
LOWER VALUE: 30%. HIGHER
VALUE: 55%.
STILL FLASHING.
PRESS OK BUTTON TO ACCEPT NEW VALUE AND GO TO NEXT
SETTING.
NOTE: FOR HRV CONSTRUCTO 1.5V, 1.5ES, 2.0ES,
ERV CONSTRUCTO 2.0ES AND VÄNEE 100H,
200H AND 90H-V UNITS, PRESS OK BUTTON TO
ACCEPT NEW VALUE AND QUIT SETTING MENU.


OR

OR
USE UP OR DOWN
ARROW TO CHANGE TO
RECIRCULATION IN
STANDBY.
PRESS OK BUTTON TO ACCEPT AND
QUIT SETTING MENU.
RECIRCULATION ARROWS ARE
TURNING AND rE FLASHES TO SHOW
THAT RECIRCULATION² IS IIN
STANDBY.
TWO LINES ARE FLASHING TO SHOW THAT
OFF¹ IS IN STANDBY
(DEFAULT CONFIGURATION SETTING).

PRESS OK BUTTON TO ACCEPT AND
QUIT SETTING MENU.
RECIRCULATION IN STANDBY*: ON20 MIN/HMODE, THE VENTILATION UNIT
RECIRCULATES THE INSIDE AIR FOR 40 MINUTES ON
HIGH SPEED AND EXCHANGES AIR WITH THE OUTSIDE
ON LOW SPEED DURNG THE REMAINING 20 MINUTES
OF THE HOUR.
POWER FAILURE
IFTHERE IS APROBLEM WITH THE WALL CONTROL, AN ERROR CODE WILL APPEAR ON LCD
SCREEN; IT COULD BE E1, E3 OR E7. IFTHIS SITUATION OCCURS, UNPLUG THE VENTILATION
UNIT FOR 20 SECONDS AND THEN REPLUG IT. IFTHE ERROR CODE IS STILL PRESENT, PLEASE
CALL YOUR INSTALLER.
ERROR CODES
THE MAINTENANCE INDICATOR IS REPRESENTED BY AN
M IN AROUNDED TRIANGLE, AT THE TOP OF THE HOUSE
(SEE AT RIGHT).IFTHIS INDICATOR IS FLASHING, PERFORM
THE REGULAR MAINTENANCE, AND IF IT IS NOT FLASHING,
PERFORM THE ANNUAL MAINTENANCE (REFER TO THE
VENTILATION UNIT USER GUIDE).
RESETTING MAINTENANCE INDICATOR: PRESS SIMULTANEOUSLY ON BOTH
ARROW BUTTONS, MAINTENANCE INDICATOR WILL DISAPPEAR FROM LCD
SCREEN.
MAINTENANCE INDICATOR


AND
THE WALL CONTROL MUST BE RESET IF IT WAS PREVIOUSLY CONNECTED TO ANOTHER
VENTILATION UNIT. TOPERFORM THE RESET:
PRESS SIMULTANEOUSLY ON DOWN ARROW AND OK BUTTTONS FOR
8 SECONDS.
UNPLUG THE VENTILATION UNIT FOR 30 SECONDS.
PLUG BACK THE VENTILATION UNIT IN POWER SOURCE.
WALL CONTROL RESET PROCEDURE


0062
8 sec.

Other Venmar Control Unit manuals

Venmar DECO-TOUCH WALL CONTROL Instruction Manual

Venmar

Venmar DECO-TOUCH WALL CONTROL Instruction Manual

Popular Control Unit manuals by other brands

XIA Pixie-16 MZ-TrigIO user manual

XIA

XIA Pixie-16 MZ-TrigIO user manual

Emerson AVENTICS 501 Series Installation and maintenance instructions

Emerson

Emerson AVENTICS 501 Series Installation and maintenance instructions

Viessmann VITOTRONIC 300 Technical data manual

Viessmann

Viessmann VITOTRONIC 300 Technical data manual

Fortec Star COMe-bSC6 manual

Fortec Star

Fortec Star COMe-bSC6 manual

HomeMatic HmIP-PCBS Installation instructions and operating manual

HomeMatic

HomeMatic HmIP-PCBS Installation instructions and operating manual

Bosch rexroth DBD 1X/ E Series operating instructions

Bosch

Bosch rexroth DBD 1X/ E Series operating instructions

Racal Instruments 1260 VXI manual

Racal Instruments

Racal Instruments 1260 VXI manual

Quectel EM160R-GL Hardware design

Quectel

Quectel EM160R-GL Hardware design

Siemens SIRIUS 3RW5 series Equipment manual

Siemens

Siemens SIRIUS 3RW5 series Equipment manual

RIB S1 manual

RIB

RIB S1 manual

Pickering 40-581 user manual

Pickering

Pickering 40-581 user manual

Pentair AURORA CBV-S/A Installation and operation manual

Pentair

Pentair AURORA CBV-S/A Installation and operation manual

Supra Vision PV1100 owner's manual

Supra

Supra Vision PV1100 owner's manual

Viega 9690TW Instructions for use

Viega

Viega 9690TW Instructions for use

TLV JH-B series instruction manual

TLV

TLV JH-B series instruction manual

Omnitron iConverter TM3 quick start guide

Omnitron

Omnitron iConverter TM3 quick start guide

M-system R7M-DC16B instruction manual

M-system

M-system R7M-DC16B instruction manual

Bull 1GB Intel Ethernet Switch Module Installation and user guide

Bull

Bull 1GB Intel Ethernet Switch Module Installation and user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.