Venmar DECO-TOUCH WALL CONTROL Instruction Manual

6. MOUNT THE WALL CONTROL TO THE WALL.
PLUG THE VENTILATION UNIT AND TEST THE
WALL CONTROL OPERATION.
DECO-TOUCH WALL CONTROL INSTALLATION AND OWNER GUIDE
THIS WALL CONTROL CAN BE USED WITH THE FOLLOWING VENTILATION UNITS:
VENMAR AVS SOLO, DUO, HE, COMPACT, CONSTRUCTO 1.0*, HRV AND ERV EKO 1.5, NOVOFIT, KUBIX HRV PLUS AND KUBIX ERV
VÄNEE GOLD SERIES, HE*, 60H*, HRV AND ERV 90H-V ECM, NOVO+, VIGÖR HRV PLUS AND VIGÖR ERV
IT IS NOT COMPATIBLE WITH OTHER VENTILATION UNITS.
*CONSTRUCTO 1.0 AND VÄNEE 60H BUILT IN AUGUST 2008 AND LATER, AND VÄNEE HE BUILT IN JULY 2006 OR LATER. THE DATE CODE ON
THE UNIT IS PART OF ITS 13-DIGIT SERIAL NUMBER. FOR EXAMPLE, THE SERIAL NUMBER XXXX0708XXXXX, WHERE 07 IS THE YEAR AND
08 THE MONTH (AUGUST); THE DATE CODE IS ALWAYS THE FIFTH, SIXTH, SEVENTH AND EIGHTH DIGITS.
ALWAYS DISCONNECT THE UNIT BEFORE MAKING ANY CONNECTIONS. FAILURE TO DISCONNECT POWER COULD RESULT IN ELECTRIC SHOCK OR DAMAGE
TO THE WALL CONTROL OR ELECTRONIC MODULE INSIDE THE UNIT.
WARNING
!
FAILURE TO COMPLY WITH THE FOLLOWING CAN CAUSE ERRATIC OPERATION OF THE UNIT:
•NEVER INSTALL MORE THAN ONE MAIN WALL CONTROL PER VENTILATION UNIT.
•KEEP CONTROL LOW VOLTAGE WIRING AT LEAST 1 FOOT (305 MM) AWAYFROMMOTORS, LIGHTING BALLAST, LIGHT DIMMING CIRCUIT AND POWER
DISTRIBUTION PANEL. DO NOT ROUTE CONTROL WIRING ALONGSIDE HOUSE POWER WIRING.
•E
NSURE THE WIRES ARE SECURELY CONNECTED.
CAUTION
WALL CONTROL INSTALLATION
5. STRIP THE END OF THE CABLE TO ACCESS THE
4 WIRES. STRIP THE END OF EACH WIRE.
USING A SMALL FLAT BLADE SCREWDRIVER,
CONNECT EACH WIRE TO ITS CORRESPONDING
TERMINAL ON THE BACK OF THE WALL
CONTROL: YELLOW WIRE TO “Y”, RED WIRE
TO “R”, GREEN WIRE TO “G” AND BLACK
WIRE TO “B”.
Y
B
G
R
VE0243
2. CUT A 2 7/8” X1 ³/8” HOLE IN WALL AT A
CONVENIENT LOCATION FOR THE WALL CONTROL.
ROUTE THE CABLE FROM THE UNIT TO THIS
HOLE.
NOTE:DIMENSIONS SHOWN ARE FOR AN
INSTALLATION WITHOUT WALL BOX.
1. UNPLUG THE VENTILATION UNIT FROM POWER SOURCE.
VC0115
3. TEMPORARILY PLACE THE SWITCH OVER THE
HOLE AND MARK BOTH MOUNTING SCREW
HOLE POSITIONS.
4. REMOVE THE SWITCH, DRILL BOTH SCREW
HOLES (Ø 3/16”) IN WALL AND INSERT WALL
ANCHORS (INCLUDED).
VC0116A
Ø 3/16”, typ.
OR
WALL CONTROL USE
BACKLIGHT
IF THE BACKLIGHT IS NOT ILLUMINATED, THE FIRST BUTTON PRESSED (NO MATTER
WHICH BUTTON) SHALL TURN ON THE BACKLIGHT. THE BACKLIGHT REMAINS ILLUMINATED
FOR 10 SECONDS AFTER THE LAST BUTTON PRESSED.
OPERATING MODES
OFF
PUT THE UNIT ON STAND-BY MODE, SO IT WILL ONLY RESPOND TO
OVERRIDE WALL CONTROLS (IF PRESENT). ONLCD SCREEN, ONLY THE
HOUSE IS VISIBLE SHOWING THE CONTROL IS POWERED ON.
THIS IS THE FACTORY DEFAULT MODE.
RECIRC
AIR IS RECIRCULATED INSIDE THE HOUSE AT HIGH SPEED.
20 MIN/H
THE VENTILATION UNIT EXCHANGES AIR INTERMITTENTLY ON A ONE HOUR
CYCLE AS FOLLOWS: OFF FOR 40 MIN. (OR RECIRCULATION ON
HIGH SPEED FOR 40 MIN., SEE NEXT SECTION ON BACK PAGE) AND
THEN EXCHANGE AIR DURING 20 MIN. ON LOW SPEED. REPEAT CYCLE
AFTER THE 20 MIN. OF AIR EXCHANGE.
MIN
AIR IS EXCHANGED WITH THE OUTSIDE ON LOW SPEED.
MAX
AIR IS EXCHANGED WITH THE OUTSIDE ON HIGH SPEED.
OPERATING MODES (CONT’D)
TO CHANGE THE OPERATION MODE OF THE VENTILATION UNIT, PRESS
THE UP OR DOWN ARROW BUTTON. OPERATING MODE LABEL WILL
THEN SCROLL UP OR DOWN ON LCD SCREEN.
09947 REV. B

WALL CONTROL USE (CONT’D)
HOW TO SET THE RELATIVE HUMIDITY (RH) LEVEL AND CHOOSE BETWEEN
OFF IN STANDBY OR RECIRCULATION IN STAND-BY
SETTING THE RELATIVE HUMIDITY LEVEL ALLOWS TO SELECT THE MAXIMUM DESIRED
INDOOR HUMIDITY LEVEL (IN PERCENTAGE). THIS VALUE WILL BE USED TO START THE
DEHUMIDISTAT OVERRIDE (AIR EXCHANGE IN HIGH SPEED).
PRESS AND HOLD OK FOR 3 SEC. TO
ACCESS THE SETTINGS MENU. THE
BACKLIGHT WILL BE ACTIVATED DURING
ALL THE PROCEDURE.
THE RELATIVE HUMIDITY ARROW AND
VALUE WILL FLASH (DEFAULT SETTING:
45%).
USE UP OR DOWN ARROW
TO CHANGE THE VALUE. THE
VALUE CHANGES BY 1%
INCREMENTS. LOWER VALUE:
30%. UPPER VALUE: 55%.
STILL FLASHING.
PRESS OK BUTTON TO ACCEPT THE
NEW VALUE AND GO TO NEXT SETTTING.
RECIRCULATION ARROWS ARE TURNING
AND rE FLASHES TO SHOW THAT
RECIRCULATION² IS IN STANDBY.
PRESS OK BUTTON
TO ACCEPT AND QUIT
SETTING MENU.
OR
USE UP OR DOWN
ARROW TO CHANGE TO
RECIRCULATION IN
STANDBY.
TWO LINES ARE FLASHING TO SHOW
THAT OFF¹ IS IN STAND BY (DEFAULT
CONFIGURATION SETTING).
OR
OR
RESETTING MAINTENANCE INDICATOR: PRESS SIMULTANEOUSLY ON
BOTH ARROW BUTTONS, MAINTENANCE INDICATOR WILL DISAPPEAR
FROM LCD SCREEN.
AND
MAINTENANCE INDICATOR
THE MAINTENANCE INDICATOR IS REPRESENTED
BY AN M IN A ROUNDED TRIANGLE, AT THE TOP
OF THE HOUSE (SEE BESIDE). IF THIS INDICATOR
IS FLASHING, PERFORM THE SEMI-ANNUAL
MAINTENANCE, AND IF IT IS NOT FLASHING, PERFORM
THE ANNUAL MAINTENANCE (REFER TO THE
VENTILATION UNIT USER GUIDE).
DEHUMIDISTAT OVERRIDE SELECTION
IN THE OPERATING MODES MIN, MAX, 20 MIN/H AND RECIRC, THE USER CAN
SELECT A DEHUMIDISTAT OVERRIDE SO THAT IF THE RELATIVE HUMIDITY (RH) IN THE
HOUSE EXCEEDS THE RH SETTING PREVIOUSLY STORED, THE VENTILATION UNIT WILL
EXCHANGE IN HIGH SPEED UNTIL THE TARGET INDOOR RH SETTING IS REACHED.
AN AIR EXCHANGER IS NOT A DEHUMIDIFIER, BUT IT CAN CHANGE THE INDOOR RELATIVE
HUMIDITY BY BRINGING IN DRIER OR MORE HUMID AIR FROM OUTSIDE DURING NON
HEATING SEASON. THE DEHUMIDISTAT OVERRIDE FUNCTION IS USEFUL TO REDUCE
INDOOR RH WHEN THE OUTDOOR AIR IS COOL AND DRY DURING THE HEATING SEASON.
SELECT A TARGET RH BETWEEN 30% AND 55% ACCORDING TO YOUR COMFORT.
WHEN OUTDOOR RELATIVE HUMIDITY IS HIGH (E.G. IN SUMMER), TURN OFF THE OVERRIDE
BY PRESSING OK UNTIL THE RH DISPLAY DISAPPEARS.
WHEN THE DEHUMIDISTAT OVERRIDE IS ACTIVATED, THE AUTO INDICATOR
WILL APPEAR ON LCD SCREEN TO SHOW THAT THE ACTUAL MODE IS
BEING OVERRIDDEN. ALSO, THE RELATIVE HUMIDITY APPEARS (IF IT WAS
NOT SHOWN, SEE EXAMPLE BESIDE). ONCE THE TARGET HUMIDITY
LEVEL IS REACHED, THE UNIT GOES BACK INTO ITS ORIGINAL OPERATING
MODE AND AUTO DISAPPEARS FROM LCD SCREEN.
NOTE: IF THE ACTUAL MODE IS MAX, ONLY THE RELATIVE HUMIDITY LEVEL
APPEARS ON SCREEN; AUTO LABEL WILL NOT APPEAR.
TO ENGAGE THE DEHUMIDISTAT OVERRIDE, PRESS OK. THE ACTUAL INDOOR RH AND
THE %HUM LABEL APPEAR ON LCD SCREEN.
NOTE: IF THE ACTUAL RH IS LESS THAN 20%, THEN THE HUMIDITY INDICATOR
WILL DISPLAY “LO”, AND IF THE ACTUAL RH IS GREATER THAN 80%, THEN
THE HUMIDITY NDICATOR WILL DISPLAY “HI”.
TO TURN OFF THE DEHUMIDISTAT OVERRIDE, PRESS OK AGAIN. THE RH AND %HUM
DISPLAY WILL DISAPPEAR FROM LCD SCREEN.
POWER FAILURE
AFTER A POWER FAILURE, THE WALL CONTROL RETURNS TO ITS ORIGINAL OPERATION
MODE. ALL SETTINGS ARE KEPT IN MEMORY.
ERROR CODES
IF THERE IS A PROBLEM WITH THE WALL CONTROL, AN ERROR CODE WILL APPEAR ON
THE SCREEN; IT COULD BE E1, E3 OR E7. IS THIS SITUATION OCCURS, UNPLUG THE
VENTILATION UNIT FOR 20 SECONDS AND THEN REPLUG IT. IF THE ERROR CODE IS STILL
PRESENT, PLEASE CALL YOUR INSTALLER.
PRESS OK BUTTON TO ACCEPT AND
QUIT SETTING MENU.
OFF IN STAND BY:ON20 MIN/H MODE, THE VENTILATION UNIT IS OFF DURING
40 MINUTES AND EXCHANGE AIR WITH THE OUTSIDE ON LOW SPEED
DURING THE REMAINING 20 MINUTES OF THE HOUR. THIS IS THE
DEFAULT VALUE.
RECIRCULATION IN STAND BY:ON20 MIN/H MODE, THE VENTILATION UNIT
RECIRCULATES THE INSIDE AIR FOR 40 MINUTES
ON HIGH SPEED AND EXCHANGE AIR WITH THE
OUTSIDE ON LOW SPEED DURING THE REMAINING
20 MINUTES OF THE HOUR.
Other Venmar Control Unit manuals
Popular Control Unit manuals by other brands

jablotron
jablotron JA-120N quick start guide

Metal Work
Metal Work EB 80 user manual

Pfeiffer Vacuum
Pfeiffer Vacuum EVB 160 PA operating instructions

Grundfos
Grundfos CIM 500 Installation and operating instructions

TP-Link
TP-Link kasa smart KE100 V1.20 quick start guide

Chore-Time
Chore-Time PDS Control 4 Installation and operator's manual