Installation and Wiring Instructions for the Lo-Carbon Silhouette Range of
Extractor Fans.
IMPORTANT:
READ THESE INSTRUCTIONS
BEFORE COMMENCING THE
INSTALLATION
DO NOT install this product in areas where the following may be present or occur:
•Excessive oil or a grease laden atmosphere.
•Corrosive or flammable gases, liquids or vapours.
• Ambient temperatures higher than 40°C or less than –5°C.
• Possible obstructions which would hinder the access or removal of the Fan.
SAFETY AND GUIDANCE NOTES
A. All wiring to be in accordance with the current I.E.E. Regulations, or the appropriate standards of
your country and MUST be installed by a suitably qualified person.
B. The Fan should be provided with a local isolator switch capable of disconnecting all poles, having a
contact separation of at least 3mm.
C. Ensure that the mains supply (Voltage, Frequency, and Phase) complies with the rating label.
D. The Fan should only be used in conjunction with the appropriate Vent-Axia products.
E. The fan should only be used in conjunction with fixed wiring.
F. When the Fan is used to remove air from a room containing a fuel-burning appliance, ensure that
the air replacement is adequate for both the fan and the fuel-burning appliance.
G. The Fan should not be used where it is liable to be subject to direct water spray for prolonged periods
of time.
H. Where ducted Fans are used to handle moisture-laden air, a condensation trap should be fitted.
Horizontal ducts should be arranged to slope slightly downwards away from the Fan.
I. This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person responsible for their safety.
J. Children should be supervised to ensure that they do not play with the appliance.
K. Stationary appliances not fitted with means for disconnection from the supply mains having a
contact separation in all poles that provide full disconnection under over voltage category III, the
instructions state that means for disconnection must be incorporated in the fixed wiring in
accordance with the wiring rules.
L. The exterior grille should be at least 2.3m above the ground to prevent people from being able to
access moving parts. If the external grille is positioned between 0-2.3m from the ground, Please
use the Vent-Axia wall kit as detailed below to ensure people cannot access the fans impeller from
the outside.
DESCRIPTION
The Lo-Carbon Silhouette 100mm fan is an axial extraction fan suitable for domestic
bathrooms and W.C’s. The Lo-Carbon Silhouette 150mm fan is an axial extraction fan
suitable for domestic kitchens and utility rooms. They are available as wall or panel
mounted models with shutter timer and humidity combinations.
Long life ball bearing DC motor with anti-vibration mounts provides low noise
transmission into plasterboard/panels for silent operation.
The fan can be wall or panel/ceiling mounted.
ACCESSORIES (not supplied)
WALL FITTING KIT
A range of 100mm and 150mm wall kits are
available for installing into most walls using
telescopic liners supplied.
White Brown
100 254102 254100
150 140902
140903
Stock Reference