Vicon VAX-PCR-35L User manual

This Quick Start Guide is intended for experienced installing
technicians. It is a basic reference to ensure all connections are
properly made. It is for models VAX-PCR-35L and VAX-PCR-640L.
For additional information please refer to Vicon's website
vicon-security.com.
1.0 Introduction
A key component of a physical security electronic access control
system, a mobile-ready reader combining BLE and proximity
technologies is based on RFID technology. In operation
it is capable of reading data stored on a proximity credential via radio
frequency—or reading data from mobile credential stored in a
smartphone’s wallet app via BLE technology—and without physical
contact, and then passing the data obtained to the physical access
control system. Access control systems typically manage
and record the movement of individuals through a protected area,
such as a locked door.
2.0 Mounting Provisions
Each reader may be installed either indoors or outdoors. Mounting
options shown in the table below. Use supplied #6 mounting screws,
or equivalent security screws, for installation.
Model Mullion Mount Single-Gang Wall Mount*
VAX-PCR-35L • •
VAX-PCR-640L •
*Plastic or metal.
3.0 Reader Wiring
Wiegand Magstripe
Conductor Function Conductor Function
Red DC (8-14 VDC) Red DC (8-14 VDC)
Black Ground Black Ground
Green Data 0 Green Clock
White Data 1 White Data
Brown Red LED a Brown Red LED
Orange Green LED b Orange Green LED
Yellow Not Used Yellow Not Used
Blue Beeper Blue Beeper
Violet Not Used Violet Not Used
Drain Shield Ground Drain Shield Ground
4.0 Cable Requirements
24 AWG minimum, multi-conductor stranded with an overall foil shield,
for example Belden 9535 or similar, supporting the ve conductors
comprising the physical layer of the Wiegand interface (power,
ground, data 0, data 1, and/or beeper and LED). Alternatively, Belden
9539 or similar, for all reader functions. Contact your access control
system manufacturer for their specic requirements. Per the SIA’s
Wiegand specication, maximum cable length is 500 feet (152 m).
5.0 Output Formats
• Wiegand (industry standard 26-bit Wiegand and custom
Wiegand formats)
• Magnetic Stripe (ABA Track II, clock and data, with card present)
6.0 Grounding
Shield (drain) continuity must run from the reader to the access
panel. Shield (drain) and reader ground must be tied together at
the access panel and connect to an earth ground at one point.
7.0 Power
Reader may be powered by the access panel. A linear power
supply is recommended for best operation.
8.0 Voltage and Current
Voltage: 8 to 14 VDC
Current Draw: 60mA typical, 90mA peak
9.0 Connection
Connection must be done in accordance with NFPA 70. Do
not connect to a receptacle controlled by a switch. Connect
to a power limited DC voltage source.
10.0 Troubleshooting
1. When the reader is rst powered on it will beep 4-times,
and the LED will shine red.
2. Presenting a supported access credential will result in the
reader beeping and the LED ashing once.
3. Mobile operation is optimized for smartphones supporting
BLE (Bluetooth LE) version 4.2 or newer. Further, for
the downloading of mobile access credentials, a stable,
high-quality internet connection is recommended.
NOTE: The access panel controls LED functionality, such as
switching the LED to green.
XX274-85
WIRING NOTES:
aSingle Line LED: This is the standard operating mode and does not make
use of the Orange conductor. The LED is Red when the reader is idle and
ashes when a card is presented. The LED turns Green when the Brown
Conductor is pulled low by the access control panel.
bDual Line LED: This mode makes use of both the Brown and Orange
conductors. The Brown conductor controls the Red LED and the Orange
conductor controls the Green LED. LED states are determined by the
access control system option and capability.
Unused conductors should be trimmed, isolated and taped back to prevent
unintended current ows. Apply positive voltage only to the Red DC Conductor.
QUICK INSTALLATION GUIDE
VAX-PCR-35L AND VAX-PCR-640L
MOBILE-READY PROXIMITY READERS

If the reader does not recognize the mobile credential or card or tag
(no beep, no LED ash) or exhibits short read range, please see the
table below for possible causes and solutions.
Possible Cause Corrective Action
Incorrect cabling Verify gauge, connections and
cabling length
Not enough power 12 VDC recommended
Incorrect
credential used
Verify if credential technology
is supported
Reader/access panel
not properly grounded
Earth ground needed—verify shield and
reader ground are tied at access panel
and connect to ground at one point
Supply generating
interference
Linear power supply recommended,
verify switching power supply before use
Should any of the corrective actions mentioned above not improve
performance, disconnect the reader from the access panel and power
it with a separate power supply or 9 VDC baery and re-test card
functionality. By powering the readers separately, most variables
that may lead to reduced performance can be eliminated. Should
the problem persist, please contact Vicon Technical Support.
Operating Temperature: –31° F to +150° F (–35° C to +66° C)
Operating Humidity: 0% to 90% Relative Humidity
IP Rating: IP67-rated for outdoor use
Access Control Performance Levels Conforming to UL STD 294:
Model
Destructive
Aack
Line
Security Endurance
Standby
Power
VAX-PCR-35L Level I Level I Level IV Level I
VAX-PCR-640L Level II Level I Level IV Level I
Grade Classication Certied to CAN/ULC STD 60839-11-1:
Risk Level Application
Skill/
Knowledge
of Aackers
Typical
Examples
Grade 2 Grade 2 Grade 2 Grade 2
Many Vicon Readers carry the following certications:
FCC Compliance Statement: This device complies with part 15 of the FCC
rules. Operation is subject to the following two conditions: (1) this device may
not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Caution: Changes or modications not expressly approved by Vicon Industries
could void the user's authority to operate the equipment.
Product can be used without license conditions or restrictions in all European
Union countries, including Austria, Belgium, Bulgaria, Cyprus, Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, Netherlands, Poland, Portugal, Romania,
Slovakia, Spain, Sweden, United Kingdom, as well as other non-EU countries,
including Iceland, Norway, and Switzerland.
This device contains licence-exempt transmier(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licence-exempt
RSS(s). Operation is subject to the following two conditions: (1) This device
may not cause interference. (2) This device must accept any interference,
including interference that may cause undesired operation of the device.
L’émeeur/récepteur exempt de licence contenu dans le présent appareil
est conforme aux CNR d’Innovation, Sciences et Développement économique
Canada applicables aux appareils radio exempts de licence. L’exploitation est
autorisée aux deux conditions suivantes : (1) L’appareil ne doit pas produire de
brouillage; (2) L’appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d’en compromere le fonctionnement.
Note: This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and,
if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
For proper PIN security with keypad readers, please review
PIN Best Practices Reference Document.
QUICK START GUIDE
VAX-PCR-35L AND VAX-PCR-640L
MOBILE-READY PROXIMITY READERS
Product specications are subject to change without notice. ©2022 Vicon Industries. All rights reserved. Vicon and its logo are registered U.S. trademarks and VAX and its
logo are trademarks of Vicon Industries Inc. All other trademarks are the property of their respective owners.
vicon-security.com
P/N: 8009-8274-85-00 l REV March 2022
Vicon Industries Inc.
Tel: 631-952-2288
Toll Free: 800-645-9116
Fax: 631-951-2288
24-Hour Technical Support:
800-34-VICON (800-348-4266)
UK: 44/(0) 1489-566300
This manual suits for next models
1
Other Vicon IP Access Controllers manuals