INSULATION TESTER INSTUCTION MANUAL
1. Introduction
The digital megohmmeter uses the DC-excited transducer to convert DC 12V to DC high voltage 1000V/2500V. The main
amplifier tests the insulation voltage y the current ratio measurement of traditional megger. The input terminal uses micro-
current to test anti-interference circuit and the output terminal adopts the division function of dou le integrating digital
voltmeter to process the data conversion. It is characteristic of strong loading capacity, high anti-interference of electric field,
porta le operation, wide range, acklight display and so on. It could also e used to test commercial electric power. With its
sta le performance and high grade appearance, it is widely used to test the insulated voltage resistance for electrical equipment,
instrumentation, ca les and so on.
2. Appearance Description
1.2.3.4. Voltage Selection Switch (It includes AC750V/200M/ 2GΩ/20GΩ)
5. Voltage Selection Switch (1000V/2500V) (except AC750V)
6. Power Switch: Self-locking power switch (POWER).
7. High voltage indication: LED display.
8. Test Switch
9. LCD display: display the measuring value and unit sym ol.
10. Instrument mode
11. L: jack for circuit under test.
12. G: Protection jack. When the o ject under test is requested to add
the protection ring to eliminate leakage effects, the electrode wire
of protection ring should e connected to "G" jack.
13. ACV: Input end for AC voltage measurement.
14. E: Jack for o ject under test.
15. Power adapter jack ( ).
3. Technica Features
3.1. General Features
(1) Display: 84.8×59.8mm LCD display. The max display “1999”.
(2) Over range indication: the MSD shows "1" when it is over ranged.
(3) Alarm function: the meter will alarm automatically when the tested resistance is elow the lower range and the reading is
invalid.
(4) Power supply: #5 atteries LR6 (1.5) ×8.
(5) Low attery indication: “ ”displays
(6) Operation environment: temperature 0~40℃
,30% R.H- 85% R.H
(7) Weight: Approx. 630g (including atteries)
3.2 Technical index
Basic function Range Basic accuracy
Output Voltage 1000V/2500V ±10%
Short-circuit current <4mA √
Insulated Resistance 1000V 200MΩ:6.0-199.9MΩ ±(5%±5 digit)
2GΩ:0.06-1.999GΩ ±(5%±5 digit)
20GΩ:0.6-19.99GΩ ±(5%±5 digit)
Insulated Resistance 2500V 200MΩ:5-199.9MΩ ±(5%±5 digit)
2GΩ:0.05-1.999GΩ ±(5%±5 digit)
20GΩ:0.5-19.99GΩ ±(5%±5 digit)
200GΩ:5.0-199.9GΩ ±(5%±5 digit)
Voltage Measurement AC750V ±(1% +6 digit)
Jack Position Insulated Resistance: L、E AC750V: ACV G
ACV750V input impedance: 1MΩ.