VIDICON IX User manual

PRODUCT FEATURES DETECTION PATTERNS
INSTALLATION INSTRUCTIONS
IX
DIGITAL PIR & MICROWAVE
DETECTOR With
PET IMMUNITY up to 25 kg
The IX is a combination of PIR & MW detectors, providing
protection from intruders by PYRO sensor element and
MW (based on Doppler concept).
Using micro controller for PIR & MW signal analyzing,
with special ASIC technology for PIR pulse processing,
IX eliminates false alarms, caused by small animals and
Pets.
•Four Element Imaging Technology “Quad”.
•Microwave detection based on Doppler concept.
•Unique Microwave Motion Sensor Module with
microstrip patch antenna.
•VLSI based electronics with movement speed
spectrum analysis.
•Height installation calibrations free.
•User-friendly installation with or w/o swivel bracket.
•2-way Microwave sensitivity adjustment.
•2-way PIR sensitivity adjustment.
•Bi directional temperature compensation.
•Environmental immunity.
•Pet immunity up to 25Kg (Selectable: 15Kg or 25Kg).
Pet active bellow 1m.
•LED ON/OFF Jumper
•EOL –spare Terminal
•Tamper Switch
OPTIONS•Long Range Curtain Lens
•Wall & Ceiling Mount Bracket
Fig. 1 - Wide Angle Lens
Fig 2 - Long Range Curtain Lens – OPTION
SELECT MOUNTING LOCATION PET IMMUNITY MOUNTING THE DETECTOR
Choose a location most likely to intercept an intruder.
See detection pattern fig. 1 and fig.2.
The IX performs best when provided with a constant and
stable environment and background.
The quad-element high quality sensor detects motion
crossing the beam; it is slightly less sensitive detecting
motion toward the detector.
Long Range Curtain Lens - OPTION
When pet immunity is required, optional Long Range
Curtain Lens cannot be used. Pet immunity can only be
achieved with Wide Angle Lens.
AVOID THE FOLLOWING LOCATIONS:
Facing direct sunlight.
Facing areas that may change temperature
rapidly.
Areas where there are air ducts or substantial
airflows.
Avoid screen, curtain that may block detection
area.
Do not install outdoors.
Pet immunity is most effective on the following sized
animals:
Rodents = 5 to 12cm high
Cats = 5 to 35 cm high at normal room temperature.
Small to medium sized dogs = 10 to 45cm high at
normal room temperature.
When a dog jumps up on desks, the IX may detect it.
Adjust detection area to avoid such places.
Mount between 2.1 and 2.4m. (For better immunity,
especially for medium sized dogs, mount as close to
2.4m, as possible).
Do not angle detector towards the ground or use the
angle bracket.
Mount flat on the wall or in the corner.
For best pet immunity, limit the detectors field of view to
10~12m maximum in any direction.
Pulse Count Low is not required for Pet Immunity
applications.
Use Low pulse only in harsh environment.
For rodents.
If any shelves within 4.5m of the detector have a height
that comes within 0.5~1m below the mounting height of
the detector and rodents can access these areas, pet
immunity will be reduced. Please select mounting
location of detectors carefully to avoid this situation.
For cats.
If there are cats, any shelves in the detection area will
reduce pet immunity.
The detector can either be wall or corner mounted.
If ceiling or special wall mounting is required, use the
optional bracket base. Refer to bracket description.
(See fig. 7)
1.Unscrew the holding screw and gently raise the front
cover (Fig. 4).
2.Carefully unscrew the PCB holding screw located on
the PC board (Fig. 6).
3. Break out the desired knockout holes for proper
installation (Fig. 3).
4.The circular and rectangular indentations at the bottom
base are the knockout holes for wire entry. You may
also use mounting holes that are not in use for running
the wiring into the detector (Fig. 3).
5.For bracket mounting option - lead wire through the
bracket.
6.Mount the detector base to the wall, corner or ceiling.
(For option with bracket see Fig. 7).
7.Reinstall the PC board by fully tightening the holding
screw. Connect wire to terminal block.
8.Replace the cover by inserting it back in the
appropriate closing pins and screw in the holding
screw.
MOUNTING DESCRIPTION TERMINAL BLOCK CONNECTIONS TESTING THE DETECTOR
Terminal 1 - Marked - (GND)
Connect to ground of the control panel.
Terminal 2 - Marked + (+12V )
Connect to the positive Voltage output of 8.2 ~ 16Vdc
source (usually from the alarm control unit).
Terminals 3 & 4 - Marked TAMPER
Connect these terminals to a 24hour normally closed
protective zone in the control unit.
Once the front cover of the detector is opened, an
immediate alarm signal will be sent to the control unit.
Terminal 5 - Marked EOL
End of line option.
Terminals 6 & 7 - Marked RELAY
These are the output relay contacts of the detector.
Connect to the control at zone input.
Apply 12 Vdc power to the detector, wait 2 minutes to
finish the detector warm up time. Conduct testing with
the protected area cleared of all people.
Walk test
1. Remove front cover.
2. Make sure that PIR and MW switches are in
positions high sensitivity.
3. Make sure that LED switch is ON.
4. Replace the front cover.
5. Start walking slowly across the detection zone.
6. Observe that the detector’s LED lights whenever
motion is detected.
7. Allow 5 sec. between each test.
8. After the walk test is completed, the LED, PIR and
MW switches may be changed.
NOTE: Walk tests should be conducted, at least once a
year, to confirm proper operation and coverage of the
detector.
WIRE SIZE REQUIREMENTS
Use #22 AWG (0.5mm) or wires with a larger diameter.
Use the following table to determine required wire gauge
(diameter) and length of wire between the detector and
the control panel.
Wire Length m 200 300 400 800
Wire Diameter mm .5 .75 1.0 1.5
Wire Length ft 800 1200 2000 3400
Wire Gauge # 22 20 18 16
Fig. 3
Fig. 4
Fig. 5

SETTING UP THE DETECTOR
LED INDICATION OF ALARM SIGNAL
Switch 1 of dipswitch DIP4 use for setting - LED
Enable / Disable
Position Right – ON - LEDs ENABLE
The RED LED will activate when the detector
is in alarm condition.
Position Left – OFF - LEDs DISABLE
Note: the state of the switch “LED” does not affect the
operation of the relay.
When an intrusion is detected, the LED will activate and
the alarm relay will switch into alarm condition for 2 sec.
PIR ADJUSTMENT
PULSE COUNT CONTROL
Switch 2 of dipswitch DIP4 use for setting the PULSE
count function in order to provide PIR sensitivity control
according to the environment.
Position Left – OFF. High sensitivity - 2 PULSES - for
normal stable environment with wide angle lens.
Position Right – ON. Low sensitivity – 3 PULSES -
for harsh environments.
Note:For Long Range Lens set Switch 2 to OFF.
RANGE CONTROL
Use the Potentiometer marked “PIR” to adjust the
detection sensitivity between 15% and 100%, according
to walk test in the protected area.
(Factory setting is 57%)
Rotate the potentiometer clockwise to increase range,
counter-clockwise to decrease range.
MW ADJUSTMENT
RANGE CONTROL
Switch 3 of dipswitch DIP4 use for setting the MW
function in order to provide MW range control according
to the room size.
Position Left – OFF – Long
For room size 10m – 18m.
Position Right – ON – Short
For room size 5m – 9m.
SENSITIVITY CONTROL
Position the potentiometer “MW” at min-scale firstly,
then, along with walk testing, turn to mid-scale or max-
scale gradually until you get detection at the longest
distance for the required detection range.
Rotate the potentiometer clockwise to increase range,
counter-clockwise to decrease range.
PET IMMUNITY SETTING
Switch 4 of dipswitch DIP4 use for setting the PET
Immune function - Up to 15Kg or 25Kg, depending on
the pet weight.
Position Right - ON
Immunity to an animal up to 15 kg
Position Left - OFF
Immunity to an animal up to 25 kg
YOU MUST RESET THE DETECTOR BY DISCONNECT
POWER SUPPLY AND RECONNECT IT AFTER FEW
SECONDS.
BRACKET INSTALLATION OPTION LONG RANGE CURTAIN OPTION VISIBLE LIGHT FILTER OPTION
(1)
To remove lens, press both
lens hooks to outside and push
the lens to the front.
(4)
To fit lens press it into
the cover from the front
until "CLICK" is heard
(2)
To fit L/R mask remove
the lens, place the mask in
the center of lens housing
(3)
Press the mask into
the cover from the front
until "CLICK" is heard
(1)
Remove lens, by pressing
both lens hooks to outside and
pushing the lens to the front.
(4)
To fit lens press it into
the cover from the front
until "CLICK" is heard
(2)
Bend the FILTER
and place in the center
of lens housing
(3)
Insert the FILTER into
the two slots at lens
housing corners
TECHNICAL SPECIFICATIONS WARRANTY CONTACT US:
Detection Method Quad element PIR &
microwave pulse Doppler
Power Input 8.2 to 16 Vdc
Current Draw Active : 25.5 mA
Standby: 16.5 mA
Temperature
Compensation YES
Alarm Period 2 +/- 1 sec
Alarm Output N.C 28Vdc 0.1 A with
10 Ohm series protection
resistors
Tamper Switch N.C 28Vdc 0.1A with10 Ohm
series protection resistor - open
when cover is removed
Warm Up Period 1 min
LED Indicator Yellow LED is blinking during
warm up period and self testing
Red LED: ON during alarm
Green LED: PIR CHANNEL
Yellow LED: MW CHANNEL
Dimensions 115mm x 61mm x 37.5mm
Weight 120g
VIDICON reserves the rights to change specifications
without prior notice
VIDICON LIMITED WARRANTY
VIDICON warrants this product to be free from defects in materials and
workmanship under normal use and service for a warranty period.
VIDICON’s obligation is limited to repairing or replacing this product at its option
free of charge for materials or labor if it is proved to be defective in materials or
workmanship under normal use and service. VIDICON shall have no obligation
under this Limited Warranty or otherwise if the product is altered or improperly
repaired or serviced by anyone other then VIDICON.
There are no warranties expressed or implied of merchantability or fitness for a
particular purpose or otherwise which extend beyond the description on the face
hereof. In no case shall VIDICON be liable to anyone for any consequential or
incidental damages for breach of this or any other warranty expressed or
implied or upon any other basis of liability whatsoever even if the loss or
damage is caused by VIDICON’s own negligence or fault.
VIDICON does not represent that this product can not be compromised or
circumvented; that this product will prevent any person injury or property loss or
damage by burglary robbery fire or otherwise; or that this product will in all
cases provide adequate warning or protection. Purchaser understands that a
properly installed and maintained product can only reduce the risk of burglary
robbery or other events occurring without providing an alarm but it is not
insurance or a guarantee that such will not occur or that there will be no personal
injury or property loss or damage as a result. Consequently VIDICON shall have
no liability for any personal injury; property damage or any other loss based on
claim that this product failed to give any warning. However if VIDICON is held
liable whether directly or indirectly for any loss or damage arising under this
limited warranty or otherwise regardless of cause or origin VIDICON’s
maximum liability shall not in any case exceed the purchase price of this product
which shall be the complete and exclusive remedy against VIDICON.
VIDICON LTD.
Israel: 14 Shenkar St
Hertzelya Pituah 46733
PO BOX 12575 Israel
Tel: +972 9 9511211
Fax: +972 9 9511222
Poland: 15 Powazkowska St
01-797 Warsaw Poland
Tel: +48 22 562 3000
Fax: +48 22 562 3030
E-mail: vidicon@vidicon.pl
P/N 7101576 REV. C
Fig. 6
Fig. 7 Note:
When using the Long Range detection
option – Set Switch 2 to OFF.
Fig. 8
Other VIDICON Security Sensor manuals