PRODUCT FEATURES DETECTION PATTERNS
INSTALLATION INSTRUCTIONS
BINGO
DIGITAL PIR DETECTOR
With
PET IMMUNITY up to 25 kg
The BINGO Detector uses a special designed optical
Lens with unique Quad (Four element) PIR Sensor and
new ASIC based electronics optimized to eliminate false
alarms, caused by small animals and Pets.
The BINGO provides unprecedented levels of immunity
against visible light.
The Detector offers an exceptional level of detection
capability and stability for every security installation.
The BINGO is supplied with Wide Angle lens with PET
immune function.
•Four Element Imaging Technology “Quad”.
•ASIC based electronics.
•Immunity to animals up to 25kg (55 lbs).
•18m Detection Range with Wide Angle Lens.
•Temperature compensation.
•Compact Design for Residential Installation.
•Variable pulse width adjustment.
•Sensitivity adjustment.
•Environmental immunity.
•Height installation calibration free (1.8~2.4m).
•LED ON/OFF Jumper
•Selectable Pulse Count (1, 2 or 3)
•Selectable PET Size (15Kg or 25 Kg)
•EOL – spare Terminals
•Tamper Switch
•Sensitivity Calibration
Fig. 1 - Wide Angle Lens
Fig 2 - Long Range Curtain Lens – OPTION
SELECT MOUNTING LOCATION PET IMMUNITY MOUNTING THE DETECTOR
Choose a location most likely to intercept an intruder.
See detection pattern Fig. 1 and Fig. 2.
The BINGO performs best when provided with a
constant and stable environment and background.
The quad-element high quality sensor detects motion
crossing the beam; it is slightly less sensitive detecting
motion toward the detector.
Long Range Curtain Lens - OPTION
When pet immunity is required, optional Long Range
Curtain Lens cannot be used. Pet immunity can only be
achieved with Wide Angle Lens.
AVOID THE FOLLOWING LOCATIONS:
Facing direct sunlight.
Facing areas that may change temperature
rapidly.
Areas where there are air ducts or substantial
airflows.
Avoid screen, curtain that may block detection
area.
Do not install outdoors.
Pet immunity is most effective on the following sized
animals:
Rodents = 5 to 12cm high
Cats = 5 to 35 cm high at normal room temperature.
Small to medium sized dogs = 10 to 45cm high at
normal room temperature.
When a dog jumps up on desks, the BINGO may detect
it. Adjust detection area to avoid such places.
Mount between 2.1 and 2.4m. (For better immunity,
especially for medium sized dogs, mount as close to
2.4m, as possible).
Do not angle detector towards the ground or use the
angle bracket.
Mount flat on the wall or in the corner.
For best pet immunity, limit the detectors field of view to
10~12m maximum in any direction.
Pulse Count 2 or 3 is not required for Pet Immunity
applications.
Use 2 or 3 pulse only in harsh environment.
For rodents.
If any shelves within 4.5m of the detector have a height
that comes within 0.5~1m below the mounting height of
the detector and rodents can access these areas, pet
immunity will be reduced. Please select mounting
location of detectors carefully to avoid this situation.
For cats.
If there are cats, any shelves in the detection area will
reduce pet immunity.
The detector can either be wall or corner mounted.
If ceiling or special wall mounting is required, use the
optional bracket base. Refer to bracket description.
(See fig. 8)
1.Unscrew the holding screw and gently raise the front
cover (Fig. 3).
2.Carefully unscrew the PCB holding screw located on
the PC board (Fig. 7).
3. Break out the desired knockout holes for proper
installation (Fig. 4).
4.The circular and rectangular indentations at the bottom
base are the knockout holes for wire entry. You may
also use mounting holes that are not in use for running
the wiring into the detector (Fig. 4).
5.For bracket mounting option - lead wire through the
bracket.
6.Mount the detector base to the wall, corner or ceiling.
(For option with bracket see Fig. 8).
7.Reinstall the PC board by fully tightening the holding
screw. Connect wire to terminal block.
8.Replace the cover by inserting it back in the
appropriate closing pins and screw in the holding
screw.
OPENING THE DETECTOR MOUNTING DESCRIPTION TERMINAL BLOCK CONNECTIONS
Holding
Screw
Cover
Base
Corner mount
knockout x4 Mounting
knockout x4
Wiring
knockout Bracket
Screw
knockout
Holding
Screw
LED
Indicator
Lens
Cover
Terminal 1 - Marked - (GND)
Connect to ground of the control panel.
Terminal 2 - Marked + ( +12V )
Connect to the positive Voltage output of 8.2 ~ 16Vdc
source (usually from the alarm control unit).
Terminals 3&6 - Marked EOL
End of line options.
Terminals 4 & 5 - Marked TAMPER
Connect these terminals to a 24hour normally closed
protective zone in the control unit.
Once the front cover of the detector is opened, an
immediate alarm signal will be sent to the control unit.
Terminals 7 & 8 - Marked RELAY
These are the output relay contacts of the detector.
Connect to the control at zone input.
Fig. 6
Fig. 4
Fig. 5Fig. 3
SETTING UP THE DETECTOR SENSITIVITY ADJUSTMENT TESTING THE DETECTOR
PET IMMUNITYJUMPER
PULSE COUNT JUMPER
Note: For Long Range Lens set pulse count to 2.
LED ENABLE / DISABLE JUMPER
The sensitivity potentiometer should be adjusted
according to the security risk level at the installation site.
For high-risk environment adjust sensitivity close to MIN
(15%). In low risk situations, adjust sensitivitycloser to
MAX (100%), factory set to 57%.
TEST PROCEDURES
Apply 12 Vdc power to the detector, wait 2 minutes to
finish the detector warm up time. Conduct testing with
the protected area cleared of all people.
Walk test
1. Remove front cover.
2. Make sure that PULSE jumper is in position 1.
3. Make sure that LED jumper is ON.
4. Replace the front cover.
5. Start walking slowlyacross the detection zone.
6. Observe that the detector’s LED lights whenever
motion is detected.
7. Allow 5 sec. between each test.
8. After the walk test is completed, the LED and
PULSE jumpers may be changed.
NOTE: Walk tests should be conducted, at least once a
year, to confirm proper operation and coverage of the
detector.
WIRE SIZE REQUIREMENTS
Use #22 AWG (0.5mm) or wires with a larger diameter.
Use the following table to determine required wire gauge
(diameter) and length of wire between the detector and
the control panel.
Wire Length m 200 300 400 800
Wire Diameter mm .5 .75 1.0 1.5
Wire Length ft 800 1200 2000 3400
Wire Gauge # 22 20 18 16
BRACKET INSTALLATION OPTION LONG RANGE CURTAIN OPTION VISIBLE LIGHT FILTER OPTION
Bracket base
(2)
Insert the
NUT into the
bracket base
Bracket holding
screw
(4)
Lead the
wires inside
the bracket
(6)
Tighten the bracket
holding screw after
facing the detector
against the protected
area.
(5)
Attach bracket
assembly to the
detector base
(1)
Select
WALL
or
CEILING
bracket adapter
(3)
Insert the suitable Adapter into Bracket Base
(1)
To remove lens, press both
lens hooks to outside and push
the lens to the front.
(4)
To fit lens press it into
the cover from the front
until "CLICK" is heard
(2)
To fit L/R mask remove
the lens, place the mask in
the center of lens housing
(3)
Press the mask into
the cover from the front
until "CLICK" is heard
(1)
Remove lens, by pressing
both lens hooks to outside and
pushing the lens to the front.
(4)
To fit lens press it into
the cover from the front
until "CLICK" is heard
(2)
Bend the FILTER
and place in the center
of lens housing
(3)
Insert the FILTER into
the two slots at lens
housing corners
TECHNICAL SPECIFICATIONS WARRANTY CONTACT US:
Detection Method Quad (Four element) PIR
Power Input
8.2 - 16 Vdc
Current Consumption
Standby: 8mA (±5%)
Active with LED:10mA (±5%)
Active w/o LED: 6mA (±5%)
Detection Range
18m, Adjustable
Mounting
Ceiling or Wall
Pulse Width Adjustable
Alarm Period 2 sec.
Alarm Output Relay
N.C 28Vdc 0.1A with
10 Ohm in line resistor
Tamper Switch
N.C 28Vdc 0.1A with
10 Ohm in line resistor
Warm Up Period 60sec (± 5sec)
Operating Temperature -20
°
C to 50
°
C
Operating Humidity 95% max relative humidity
Range non condensing
Storage Temperature -30
°
C to 70
°
C
RFI Protection 30V/m 10 -1000MHz
EMI Protection 50,000V electrical
Interference from lightning
Dimensions
90.5mm x 61mm x 37.5mm
VIDICON reserves the rights to change specifications
without prior notice
VIDICON - WARRANTY POLICY CERTIFICATE
This Warranty Certificate is given in favor of the purchaser (hereunder the "Purchaser") purchasing the
products directly from Vidicon or from its authorized distributor.
Sub ect to the provisions of this Warranty Certificate, during the Warranty Period, Vidicon undertakes, at its
sole discretion and sub ect to Vidicon's procedures, as such procedures are form time to time, to repair or
replace, free of charge for materials and/or labor, products proved to be defective in materials or
workmanship under normal use and service. Repaired products shall be warranted for the remainder of the
original Warranty Period.
All transportation costs and in-transit risk of loss or damage related, directly or indirectly, to products
returned to Vidicon for repair or replacement shall be borne solely by the Purchaser.
Vidicon's warranty under this Warranty Certificate does not cover products that is defective (or shall become
defective) due to: (a) alteration of the products (or any part thereof) by anyone other than Vidicon; (b)
accident, abuse, negligence, or improper maintenance; (c) failure caused by a product which Vidicon did not
provide; (d) failure caused by software or hardware which Vidicon did not provide; (e) use or storage other
than in accordance with Vidicon’s specified operating and storage instructions.
There are no warranties, expressed or implied, of merchantability or fitness of the products for a particular
purpose or otherwise, which extend beyond the description on the face hereof.
This limited Warranty Certificate is the Purchaser's sole and exclusive remedy against Vidicon and Vidicon's
sole and exclusive liability toward the Purchaser in connection with the products, including without limitation
- for defects or malfunctions of the products. This Warranty Certificate replaces all other warranties and
liabilities, whether oral, written, (non-mandatory) statutory, contractual, in tort or otherwise.
In no case shall Vidicon be liable to anyone for any consequential or incidental damages (inclusive of loss of
profit, and whether occasioned by negligence of the Vidicon or any third party on its behalf) for breach of this
or any other warranty, expressed or implied, or upon any other basis of liability whatsoever. Vidicon does
not represent that these products can not be compromised or circumvented; that these products will prevent
any person in ury or property loss or damage by burglary, robbery, fire or otherwise; or that these products
will in all cases provide adequate warning or protection.
Purchaser understands that a properly installed and maintained product may in some cases reduce the risk
of burglary, fire, robbery or other events occurring without providing an alarm, but it is not insurance or a
guarantee that such will not occur or that there will be no personal in ury or property loss or damage as a
result.
Consequently, Vidicon shall have no liability for any personal in ury; property damage or any other loss
based on claim that these products failed to give any warning.
If Vidicon is held liable, whether directly or indirectly, for any loss or damage with regards to these products,
regardless of cause or origin, Vidicon’s maximum liability shall not in any case exceed the purchase price of
these products, which shall be the complete and exclusive remedy against Vidicon.
VIDICON LTD.
Israel: 14 Shenkar St
Hertzelya Pituah 46733
PO BOX 12575 Israel
Tel: +972 9 9511211
Fax: +972 9 9511222
E-mail: vidic[email protected]et.il
Poland: 15 Powazkowska St
01-797 Warsaw Poland
Tel: +48 22 562 3000
Fax: +48 22 562 3030
E-mail: vidic[email protected]l
P/N 7101527_REV_B
Immunity to an animal
up to 15 kg
Immunity to an animal
up to 25 kg
Installation for normal Stable
environment with wide-angle
lens
–
set to
1 PULSE
When operating in harsh
environment use 2 or 3 pulse
count selection.
Set jumper to ON position to
enable LED.
Set jumper to OFF position to
disable LED.
Fig. 7
Fig. 8 Note
– When using the Long Range detection
option – Set the PULSE count jumper to 2.
Fig. 9

Other VIDICON Security Sensor manuals

VIDICON PIR CRT User manual

VIDICON

VIDICON PIR CRT User manual

VIDICON IX User manual

VIDICON

VIDICON IX User manual

VIDICON STAR User manual

VIDICON

VIDICON STAR User manual

VIDICON FLASH PLUS User manual

VIDICON

VIDICON FLASH PLUS User manual

Popular Security Sensor manuals by other brands

LLOYTRON MIP SYSTEM 3 B7835 operating instructions

LLOYTRON

LLOYTRON MIP SYSTEM 3 B7835 operating instructions

Potter IDC-6 installation manual

Potter

Potter IDC-6 installation manual

DoorKing 9411 Single Channel with Aux Relay Information manual

DoorKing

DoorKing 9411 Single Channel with Aux Relay Information manual

Heath Zenith 8434 instructions

Heath Zenith

Heath Zenith 8434 instructions

Renke RS-MG41-1 user manual

Renke

Renke RS-MG41-1 user manual

SpiderAlert SPD-1000 installation instructions

SpiderAlert

SpiderAlert SPD-1000 installation instructions

THORLABS PDA015AM user guide

THORLABS

THORLABS PDA015AM user guide

Danatronics ECHO FD quick start guide

Danatronics

Danatronics ECHO FD quick start guide

Resolution Products RE210P quick start guide

Resolution Products

Resolution Products RE210P quick start guide

DITECH LS quick start guide

DITECH

DITECH LS quick start guide

Hi-Link HLK-LD2410C user manual

Hi-Link

Hi-Link HLK-LD2410C user manual

HESA HE400 quick start guide

HESA

HESA HE400 quick start guide

GE TX-5011-03-1 installation instructions

GE

GE TX-5011-03-1 installation instructions

Knauer BlueShadow 50D user manual

Knauer

Knauer BlueShadow 50D user manual

Elkron IRA14 manual

Elkron

Elkron IRA14 manual

sewerin FerroTec FT 10 operating instructions

sewerin

sewerin FerroTec FT 10 operating instructions

BST Flamonitec IFC Series operating manual

BST

BST Flamonitec IFC Series operating manual

AJAX LeaksProtect quick start guide

AJAX

AJAX LeaksProtect quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.