Vidos ZS52 User manual

Mode: ZS10 Mode: ZS30 Mode: ZS50
Mode: SZ32 Mode: ZS52 Mode: ZS82
Firma Handlowa Wena
A l. Jerozolimskie 311
05-816 Reguły, Poland
tel. +48 22 8370286; +48 22 8174008
e-mail: biuro@vidos.pl
www.vidos.pl
USER’S MANUAL
W.20190906ENG

Red-power DC input +12V - +24V
Black-power AC input ~ 12V - 24V
Brown-door status detecting
Orange-unlocking button 1
Yellow-unlocking button 2
Green-GND
Blue-NO 2
Purple-COM 2
Gray-NC 2
White-NO 1
Pink-COM 1
Aqua-NC 1
Shielded ground
Pay attention for
right polar connection
Door
bell
Shielded ground
Wiring Diagram
Door lock
DC input +12V - +24V
AC input ~ 12V - 24V
Working conditions:
o o
temperature: -20C ~ +50C
RH: 95%
Current and voltage requirements:
DC input: +12V - +24V
AC input: ~ 12V - 24V
standby current: 80mA
working current: 110mA
Applicable card mode:
EM ID card(Default)
T5557/T5567 card(Setting required)
Effective distance: 5cm
Capacity:
ZONE 1: up to 1000 passwords & card holders
ZONE 2: up to 10 passwords OR card holders
1. With internal EM reader.
2. Frequency: 125KHz.
3. Effective distance: 5cm.
4. ZONE 1: up to 1000 passwords & card holders.
ZONE 2: up to 10 passwords OR card holders.
5. Card access, code access and combined access.
6. Digital keypad operation.
7. Built-in pickproof function.
8. Watchdog timer, powerful reboot and self-recovery watchdog can connect with
the external unlock button.
9. Dual relay outputs.
10. Unlock output delay time: 0~99s.
11. IP rating: 65.
12. Dimension: 120*76*22mm.
13. Dual relay outputs for door opening, door status detecting, open door by button.
The function of door status detecting is for ZONE 1 only.
ZS10
- 1 - - 2 -

1. With internal EM reader.
2. Frequency: 125KHz.
3. Effective distance: 5cm.
4. ZONE 1: up to 1000 passwords & card holders.
ZONE 2: up to 10 passwords OR card holders..
5. Card access, code access and combined access.
6. Digital keypad operation.
7. Built-in pickproof function.
8. Watchdog timer, powerful reboot and self-recovery watchdog can connect with
the external unlock button.
9. Dual relay outputs.
10. Unlock output delay time: 0~99s.
11. IP rating: 65.
12. Dimension: 120*76*28mm.
13. Dual relay outputs for door opening, door status detecting, open door by button.
The function of door status detecting is for ZONE 1 only.
ZS30
Working conditions:
o o
temperature: -20C ~ +50C
RH: 95%
Current and voltage requirements:
DC input: +12V - +24V
AC input: ~ 12V - 24V
standby current: 80mA
working current: 110mA
Applicable card mode:
EM ID card(Default)
T5557/T5567 card(Setting required)
Effective distance: 5cm
Capacity:
ZONE 1: up to 1000 passwords & card holders
ZONE 2: up to 10 passwords OR card holders
1. With internal EM reader.
2. Frequency: 125KHz.
3. Effective distance: 5cm.
4. ZONE 1: up to 1000 passwords & card holders.
ZONE 2: up to 10 passwords OR card holders..
5. Card access, code access and combined access.
6. Digital keypad operation.
7. Built-in pickproof function.
8. Watchdog timer, powerful reboot and self-recovery watchdog can connect with
the external unlock button.
9. Dual relay outputs.
10. Unlock output delay time: 0~99s.
11. IP rating: 65.
12. Dimension: 123*79*21mm.
13. Dual relay outputs for door opening, door status detecting, open door by button.
The function of door status detecting is for ZONE 1 only.
ZS50
Working conditions:
o o
temperature: -20C ~ +50C
RH: 95%
Current and voltage requirements:
DC input: +12V - +24V
AC input: ~ 12V - 24V
standby current: 80mA
working current: 110mA
Applicable card mode:
EM ID card(Default)
T5557/T5567 card(Setting required)
Effective distance: 5cm
Capacity:
ZONE 1: up to 1000 passwords & card holders
ZONE 2: up to 10 passwords OR card holders
Matrix keypads
- 3 - - 4 -

1. With internal EM reader.
2. Frequency: 125KHz.
3. Effective distance: 5cm.
4. ZONE 1: up to 1000 passwords & card holders.
ZONE 2: up to 10 passwords OR card holders..
5. Card access, code access and combined access.
6. Digital keypad operation.
7. Built-in pickproof function.
8. Watchdog timer, powerful reboot and self-recovery watchdog can connect with
the external unlock button.
9. Dual relay outputs.
10. Unlock output delay time: 0~99s.
11. IP rating: 65.
12. Dimension: 152*45*25mm.
13. Dual relay outputs for door opening, door status detecting, open door by button.
The function of door status detecting is for ZONE 1 only.
ZS-52
Working conditions:
o o
temperature: -20C ~ +50C
RH: 95%
Current and voltage requirements:
DC input: +12V - +24V
AC input: ~ 12V - 24V
standby current: 80mA
working current: 110mA
Applicable card mode:
EM ID card(Default)
T5557/T5567 card(Setting required)
Effective distance: 5cm
Capacity:
ZONE 1: up to 1000 passwords & card holders
ZONE 2: up to 10 passwords OR card holders
1. With internal EM reader.
2. Frequency: 125KHz.
3. Effective distance: 5cm.
4. ZONE 1: up to 1000 passwords & card holders.
ZONE 2: up to 10 passwords OR card holders..
5. Card access, code access and combined access.
6. Digital keypad operation.
7. Built-in pickproof function.
8. Watchdog timer, powerful reboot and self-recovery watchdog can connect with
the external unlock button.
9. Dual relay outputs.
10. Unlock output delay time: 0~99s.
11. IP rating: 65.
12. Dimension: 155*44*10mm.
13. Dual relay outputs for door opening, door status detecting, open door by button.
The function of door status detecting is for ZONE 1 only.
ZS32
Working conditions:
o o
temperature: -20C ~ +50C
RH: 95%
Current and voltage requirements:
DC input: +12V - +24V
AC input: ~ 12V - 24V
standby current: 80mA
working current: 110mA
Applicable card mode:
EM ID card(Default)
T5557/T5567 card(Setting required)
Effective distance: 5cm
Capacity:
ZONE 1: up to 1000 passwords & card holders
ZONE 2: up to 10 passwords OR card holders
Mode indicator
Case screw
Antenna
Touch keypads
- 5 - - 6 -

1. With internal EM reader.
2. Frequency: 125KHz.
3. Effective distance: 5cm.
4. ZONE 1: up to 1000 passwords & card holders.
ZONE 2: up to 10 passwords OR card holders..
5. Card access, code access and combined access.
6. Digital keypad operation.
7. Built-in pickproof function.
8. Watchdog timer, powerful reboot and self-recovery watchdog can connect with
the external unlock button.
Working conditions:
o o
temperature: -20C ~ +50C
RH: 95%
Current and voltage requirements:
DC input: +12V - +24V
AC input: ~ 12V - 24V
standby current: 80mA
working current: 110mA
Applicable card mode:
EM ID card(Default)
T5557/T5567 card(Setting required)
Effective distance: 5cm
Capacity:
ZONE 1: up to 1000 passwords & card holders
ZONE 2: up to 10 passwords OR card holders
9. Dual relay outputs.
10. Unlock output delay time: 0~99s.
11. IP rating: 65.
12. Dimension: 165*45*23.5mm.
13. Dual relay outputs for door opening, door status detecting, open door by button.
The function of door status detecting is for ZONE 1 only.
o
NOTICE
Attention items of disassembly
(ZS10/ZS30)
Shift the
front cover up
1. Please remove the cover carefully following the manual. Not
permitted to remove with sudden force.
2. Before remove the cover, push up the front cover a few
millimeters, then follow Picture 3, lift the lower cover for less
0
than 20and remove the front cover gently.
20
Picture 1 Picture 2 Picture 3
ZS-82
- 7 - - 8 -

Before installation, position the location where the controller unit is
mounted. Please operate it according to the following steps:
1. Open the controller by loosening and removing the back case
screw at the bottom with the spline tool.
2. Use the provided drilling template to accurately locate and drill
the required holes. The four drilling holes are marked "B".
3. Use the screws provided to mount the back case on the wall. Be
sure to draw the wiring through the large centre hole in back
case, and keep level.
4. Connected accurately the system wiring following the label
enclosed on the rear.
5. Put the unit back and screw it on by using the spline tool.
Applicable mode: ZS10//30/50/ Applicable mode: ZS32
Find a suitable location to mount the keypad. Then please operate
it according to the following steps.
1. Use the provided drilling template to accurately locate and drill
the needed holes.
2. According to the wiring diagram to install.
3. Fix the unit with screws.
- 9 - - 10 -

In the setting mode:
Press the button and , the mode indicator will flash yellow, follow
the button twice, the mode indicator will turn yellow, a long beep will
be heard. It indicates that only the card access is available.
Press the button and , the mode indicator will flash yellow, follow
the button and , the mode indicator will turn yellow, a long beep will
be heard, it indicates that both the card and code access are available.
Press the button and , the mode indicator will flash yellow,
follow the button and , the mode indicator will turn yellow and a long
beep will be heard, it indicates that card and code access combined is
available.
Press the button to quit the setting mode.
1. ZONE 1 and 2 relays can be programmed for opening the lock, up to
1000 user cards and correlative codes can be stored into ZONE 1, 10
user cards or codes can be stored into ZONE 2 . In addition, ZONE 1
can be programmed for 3 modes to open the lock: card access(use card
only), card and code access(use either card or code), and combined
access(use card and code together). ZONE 2 could be programmed for
door bell.
2. Default code is 1234.
3. Input the admin default code twice (1234+1234). But
a. If the admin default code you set is two digits, please input 12 12
b. If the admin default code you set is three digits, please input 123 123
c. If the admin default code you set is five digits, please input 1 2345
1 2345
The rest may be deduced by analogy...... The admin codes is max 6 digits.
After you enter in the setting mode, the yellow LED will be on.
.
Access mode setting
NOTICE
In mode:ZS32
the button replaces .
Before installation, position the location where the controller unit is
mounted. Please operate it according to the following steps:
1. Open the controller by loosening and removing the back case
screw at the bottom with the spline tool.
2. Use the provided drilling template to accurately locate and drill
the required holes. The four drilling holes are marked "B".
3. Use the screws provided to mount the back case on the wall. Be
sure to draw the wiring through the large centre hole in back
case, and keep level.
4. Connected accurately the system wiring following the label
enclosed on the rear.
5. Put the unit back and screw it on by using the spline tool.
Applicable mode: ZS52/82
- 11 - - 12 -

In the setting mode:
Enter one set number(3 digits) from 000 to 999 data storage units,
yellow LED indicator will be flashing:
1. If red LED indicator is on, means there is data stored in this set of unit,
press the button twice to clean up;
2. If green LED indicator is on, means this number data storage unit can
be added card and passwords in.
Add card and passwords steps:
1. Enter in setting mode, and the yellow LED indicator will be flashing.
2. Input three-figure from 000 to 999 data storage units, and the green
LED indicator lighting.
3. Swipe card, and a sound "BI" means added in. Then input the correlative
passwords(correlative for the card just added in this data storage unit).
The length of passwords should be the same as admin code. For
example, the admin code is 12 (two is the length), herein should
setting two digits passwords, you can set 00-99 as your passwords.
If the admin code is 123 (three is the l ength), h erein s hould s etting
t h reed igitsp asswords, you cans et0 00-999a sy ourp asswords.T he
rest may be deduced by analogy After the sound "BI", means
card added in and passwords setting successfully.
Press the button to quit setting mode.
Add the user card and code(ZONE 1)
Set the length of passwords
In the setting mode:
Press the button and yellow LED indicator will be flashing, then
press the button and a sound "BI" as reminder, then input X(X=2,3,4,
5,6):
2--Stands for the password/code digit length is 2(00-99)
3--Stands for the password/code digit length is 3(000-999)
The rest may be deduced by analogy, and the maximum is 6.
A sound "BI" as reminder, means digit length settings uccessfully. If the
sound is "BI BI BI", means digit length is as same as the existence, and new
setting is not permitted.
Press the button to quit setting mode.
4
NOTICE Once the digit length changed, all added
cards and passwords will be cleared.
In the setting mode:
Press the button and , the yellow LED indicator will be flashing,
input two-figure from 00 to 09 data storage units, yellow LED indicator will
be flashing;
there is data stored in
this set of unit.
it means this number data storage
unit can be added card or password in.
Press the button to quit the setting mode.
1. But if red LED indicator light is on, it means
storage unit existed data, press the button twice to clean up;
2. If green LED indicator light is on,
Add card or passwords steps:
Swipe card, and a sound "BI" means added in; O R in putt hec orrelative
passwords (correlative for the card just added in this data storage unit)
the length of passwords should be as same as admin code. For
example, the admin code is 12 ( two is the length ), herein should
setting two digits passwords, you can set 00-99 as your password.
The admin code is 123(three is the length), herein should setting three
digits passwords, you can set 000-999 as your passwords. The rest
may be deduced by analogy...... After the sound "BI", means card
added in or passwords setting successfully.
Add the user card or code(ZONE 2)
In the setting mode:
Enter one set number(3 digits) from 000 to 999 data storage units,
if red LED indicator is on, means there is data stored in this set of unit, press
the button twice to delete the card and code.
Delete the user card and code(ZONE 1)
Delete the user card or code(ZONE 2)
In the setting mode:
Press the button and , the yellow LED indicator will be flashing,
input two-figure from 00 to 09 data storage units, i
there is data stored in this set of unit,
f red LED indicator light
is on, it means press the button
twice to delete the card or code.
- 13 - - 14 -

If setting lock-time as 00 means: swipe card or input password once to
open the door, swipe card or input password again to close the door.
Press the button to quit the setting mode.
In the setting mode:
Press the button and (mode indicator will flash yellow), follow
the button twice, (a continuous beep will be heard and mode indicator
will turn yellow), it indicates all user cards and codes have been cleaned
out successfully.
Press the button and (mode indicator will flash yellow), follow
the button twice, (a continuous beep will be heard and mode indicator
will turn yellow), it indicates it restores to factory defaults.
Press the button to quit the setting mode and standby.
If enter wrong information, it will imply as BI.BI. sounds. The device would
turn back without actions in 30 seconds automatically accompany with BI.
BI. sounds. If it is not in the setting mode and press incomplete numbers,
and if unlock door by card and password (combined) but only one action
is done, then it will turn back in 5s automatically accompany with BI.BI.
sounds.
Clean all user cards and codes, restores to factory defaults
In the setting mode:
Press the button and , the mode indicator will flash yellow,
enter the number from 00 to 99, the mode indicator will turn yellow in
the mean time a long beep will be heard, it indicates a success of
delay time setting. 00-99 means the delay time, eg. 05 means the
unlocking time is 5s delayed. If setting lock-time as 00 means: swipe
card or input password once to open the door, swipe card or input
password again to close the door.
Press the button to quit the setting mode.
Set the unlocking time for ZONE 1
In the setting mode:
Press the button and , the mode indicator will flash yellow, enter
the number from 00 to 99, the mode indicator will turn yellow in the mean
time a long beep will be heard, it indicates a success of delay time setting.
00-99 means the delay time, eg. 05 means the unlocking time is 5s delayed.
Set the unlocking time for ZONE 2
In the setting mode:
Press the button and , the yellow LED indicator will be flashing,
then input a new administrator code twice(The length of the new admin
code must as same as the old one) and a
Press the button to quit the setting mode.
sounds "BI" means modify
successfully.
Modify administrator code
In the setting mode:
Press the button and (mode indicator will flash yellow), follow
with the and , a long beep will be heard whilst the mode indicator
will turn yellow, pickproof alarm is turned off.
Press the button and (mode indicator will flash yellow), follow
with the and , a long beep will be heard whilst the mode indicator
will turn yellow, pickproof alarm is turned on.
Press the button to quit the setting mode.
Turn on/off the pickproof alarm
In case forget thea dminc ode,p resst heb utton a ndh oldo n,t hen
power on(Notice: DH16A-20DT/DTQ DH16A-32DT/DTQ, power on first,
then press the button in 3s). A sound "BI" as reminder, means admin
code default setting successfully.
Digit length is 2--default admin code is 12,
Digit length is 3--default admin code is 123,
Digit length is 4-default admin code is 1234,
Digit length is 5--default admin code is 12345,
Digit length is 6--default admin code is 123456(Maxmium is 6).
A. When ZONE 1 relay actived, door indicator will turn green.
B. When ZONE 2 relay actived, door indicator will turn red.
The built-in buzzer will send a continuous beeping if the photoresistor
sensor is directly exposed into the light. The buzzer will be off
automatically in 60 seconds when the light is no longer detected, or by
entering the admin code.
The pickproof alarm
- 15 - - 16 -

In the setting mode:
Press the button and , the mode indicator will flash green, it
indicates there is no master card stored, if the indicator turns red, it
indicates there is already data existed, press the button twice to clean
up the data, and then indicator will flash green, swipe the master card,
a long beep will be heard, it indicates that adding successfully.
Press the button to quit the setting mode.
Add the master card(only for ZONE 1)
Swipe the master card, the indicator will flash yellow whilst a long
"BI" will be heard, enter the setting mode. Swipe the master card again,
the indicator will turn green whilst three times rapid beep sound will be
heard-exit the setting mode.
The access control will be locked for 60s if the mistaken code
continuously input or swipe the invalid card for 5 times( both the keypad
operating and the card swiping is not available during the 60 seconds).
Detect the door status: when someone opens the door and comes in,
the door is closed, the system will automatically detect the door status
and lock the door even though it is still in delay period(For ZONE 1o nly).
.
The user code must be different from the administration code.
The code of ZONE 1 must be different from that of ZONE 2.
Using the master card enter the setting mode
NOTICE
In the setting mode:
Press the button and (mode indicator will flash yellow), follow
with the and , a long beep will be heard whilst the mode indicator
will turn yellow, the function of door bell is turned off.
Press the button and (mode indicator will flash yellow), follow
with the and , a long beep will be heard whilst the mode indicator
will turn yellow, the function of door bell is turned on.
Press the button to quit the setting mode.
NOTICE: The relay in ZONE 2 for door bell is available if the function of
door bell is turned on but the function or door lock is inactive. Press the
button in standby mode, the relay contacts one time, the door bell
ringing is triggered.
Turn on/off the door bell
After adding cards, a sound "BI" as reminder. Swipe the first added
card or input the first added card serial number(8 digits), a sound "BI"
as reminder, means added in successfully.
Press the button to quit setting mode.
Modify the user code of ZONE 1
In the setting mode:
Press the button and , the yellow LED indicator will be flashing,
then press the button and , a sound "BI" as reminder. Then input
three-figure 000 to 999 data storage units and input correlative passwords
(The length of relative passwords should as same as admin code).
Press the button to quit setting mode.
Setting access control ID(for networked modes only)
In the setting mode:
Press the button and , the yellow LED indicator will be flashing,
then press the button and , a sound "BI" as reminder. Then input
6 digits ID number, and a sound "BI" as reminder, means ID setting
successfully.
Press the button to quit setting mode.
Group cards added in ZONE 1
In the setting mode:
Press the button and , the yellow LED indicator will be flashing,
then press the button and , a sound "BI" as reminder. Then input
three-figure 000 to 999 data storage units as start added unit, and input
3 digits number indicates the cards quantity you want to add in. For
example:
1. Input 005 060--means the cards added in storage units starting
from 005, and the quantity of the whole cards added in are 60.
2. Input 060 150--means the cards added in storage units starting
from 060, and the quantity of the whole cards added in are 150.
- 17 - - 18 -

WARRANTY CARD
Seller’s seal and signature
Product name:
Model:____________________________________
..........................................................................
Date of sale
1. Wena Company shall grant a warranty for the purchase of your product for a period of 24 months
from the date of its purchase as shown on the present Warranty Card and the purchase document.
2. Product defects found during the warranty period shall be repaired free of charge within 21 working
days from the date of acceptance of your product at the service centre.
3. The user has the right to replace the product with a new one if;
> four major repairs have been conducted during the warranty period and the product is still defective;
> when it is established that an unrecoverable defect has occurred. When replacing the product with
a new one, the equivalent of items (including packaging) which are missing or damaged by the user
as well as the cost of their replacement shall be deducted.
4. The user shall deliver the defective product at its own expense to the service centre.
5. The warranty shall not cover the deterioration of the product quality caused by standard wear and
tear and in the following cases:
> the product has been used improperly or inconsistently with the product operating instructions;
> the product has been used or left in improper conditions (excessive humidity, too high or low
temperature, sunlight, etc.), maintenance and operational condition which are different from the
ones specified in the product operating instructions;
> mechanical, chemical and thermal damage;
> damage caused by external forces, e.g. overvoltage in the electrical network, atmospheric
discharges, flood, fire;
> damage resulting from improper installation, improper storage of the device or repairs conducted by
any unauthorised persons;
> damage due to incorrect voltage connection.
6. The guarantee shall cease to be valid as a result:
> breakage or damage of warranty seals;
> connection of additional equipment, other equipment than the one recommended by the product
manufacturer;
> modifications and structural changes to the product and repairs conducted beyond the Wena
service centre;
> the Guarantee Card or serial number have been changed, blurred or obliterated.
7. The Guarantee Card shall be valid only with the entered date of sale confirmed by the seller's seal
and signature.
8. The condition to perform repair works is to deliver the Product with the Warranty Card and the proof
of purchase.
9. Service Centre:
Firma Handlowa Wena
Al. Jerozolimskie 311 ,
05 - 816 Reguły / near Warsaw
Poland
tel. +48 228 370 286; +48 228 174 003
e-mail: [email protected]
www.vidos.pl
ACCESS CONTROL
- 19 - - 20 -
This manual suits for next models
5
Table of contents