Vigitron Vi5001 User manual

Vi5001 PoE Media Converter Installation Manual
Application Drawing
Media Converter
Important Safety Warning
WARNING! - To reduce the risk of fire or electric shock, do not expose
this apparatus to rain or moisture. This apparatus shall not be exposed to
dripping or splashing and no objects filled with liquids, such as vases shall
be placed on the apparatus.
WARNING! - This apparatus is a Class I product. This product must
be connected to a mains socket outlet thru an AC to DC Power supply.
WARNING! - The mains plug is used as the disconnect device and
shall remain readily operable.
Vi0017
PoE Camera
Vi3026/Vi3326
Vi5001
SFP
SFP ++
Fiber Data & PoE
Vi0017
PoE Camera
Vi3026/Vi3326
Vi5001
SFP +
Fiber Data & PoE
Vi0012
Vi5001
+
The Vi5001 connects to the optical port of Network Switch
The Vi5001 connects to another Vi5001
DO NOT OPEN
RISK OF ELECTRIC SHOCK
CAUTION
CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK,
DO NOT REMOVE COVER. NO USER SERVICEABLE
PARTS INSIDE. REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
IP Camera-end Installation
The Smart Choice for Transmission Solutions www.vigitron.com
Ethernet Switch/NVR-end Installation
- Connect an approved 12VDC power supply to the power connector of
Vi5001. A power adapter connector is provided to simplify connection.
- Connect the RJ45 connector of the Ethernet switch to the 10/100BaseT
Ethernet port of Vi5001 using a standard Cat5/6 cable of maximum
328 feet (100 m) in length.
- Connect one end of the long fiber optic cable to a SFP module, then
connect the SFP module to the SFP socket of Vi5001.
The Ethernet link, Fiber link, activity LEDs should be "ON" and "Blink" to
indicate the status of each port.
- Read these instructions.
- Keep these instructions.
- Heed all warnings.
- Follow all instructions.
- Do not use this apparatus near water.
- Clean only with a dry cloth.
- Install in accordance with the manufacturer’s instructions.
- This installation should be made by a qualified service person and should
conform to all local codes.
- DO NOT bundle UTP or Coax signals in the same conduit as high-voltage
wiring.
- To reduce the risk of fire or electrical shock, do not expose these products
to rain, moisture, dripping or splashing.
- No objects filled with liquids, such as vases, shall be placed on Vigitron
equipment.
- DO NOT install the unit in a place where the operating ambient tempera
ture exceeds 75° C.
- Make sure that the external power supply output voltage is in the recom
mended range.
- Do not install near any heat sources such as radiators, heat registers,
stoves or other apparatus (including DVRs) that produce heat.
- Protect the power cord from being walked on or pinched particularly at
plugs, convenience receptacles, and the point where they exit from the
apparatus.
- Only use attachments/accessories specified by the manufacturer.
- Unplug this apparatus during lightning storms or when unused for long
periods of time.
- Refer all servicing to qualified service personnel. Servicing is required
when the apparatus has been damaged in any way, such as a power
supply cord or plug is damaged, liquid has been spilled, or objects have
fallen into the apparatus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.
- The powe plug is used as the disconnect device and shall remain readily
operable.
Vigitron’s Vi5001 is a media converter that enables Ethernet signals to be
transmitted over fiber optic cables to meet long distance transmission
applications or reusing existing analog fiber connections for IP applica-
tions. The use of SFP fiber modules resulting in compatibility with all
major single-mode and multi-mode fiber optics cables to achieve
transmission distances depending on the cable and SFP. The Vi5001 also
provides IEEE 802.3af/at PoE up to 30W to the connected IP device such
as IP camera swhen used with appropriate power supplies.
The Vi5001 is an ideal solution for converting existing analog fiber
infrastructures to IP systems. It provides a unique, reliable, and cost
effective solution to combine a variety of transmission methods to meet
any application requirement.
- Insert a suitable 100MBps SFP into the SFP socket of the Vi5001. The
SFP needs to match the specification of the fiber optics cable.
- Connect the fiber connector of the optical wire to the SFP.
- If the IP Camera is non-PoE use an approved 12VDC or 48VDC power
adapter to power the Vi5001.
- If the IP Camera is a PoE enabled use the Vi0017 or another approved
48VDC power adapter to power the Vi5001.
- Connect the IP camera RJ45 connector to the “10/100BaseT Ethernet” port
of Vi5001 using a standard Cat5/6 cable of maximum 100m in length.

Limited Lifetime Warranty
Vigitron, Inc. warrants that all Vigitron products (“Product”), if used in accordance
with these instructions, will be free of defects in material and workmanship for
lifetime defined as the duration period of time until product end of life is announce-
ment. After which Vigitron will continue to provide warranty services for a period of 3
years. Period covering valid warranty will be determined by proof of purchase in the
form of an invoice from an authorized Vigitron dealer.
Warranty will only be provided for as long as the original end user purchaser owns
the product. Warranty is not transferrable. At Vigitron's option, defective product will
be repaired, replaced or substituted with a product of equal value. This warranty
does not apply if, in the judgment of Vigitron, Inc., the Product fails due to damage
from shipment, handling, storage, accident, abuse or misuse, or if it has been used
or maintained not conforming to Product manual instructions, has been modified, or
serial number removed or defaced. Repair by anyone other than Vigitron, Inc. or an
approved agent will void this warranty. Vigitron, Inc. shall not under any circum-
stances be liable to any person for any incidental, indirect or consequential
damages, including damages resulting from use or malfunction of the product, loss
of profits or revenues or costs of replacement goods. The maximum liability of
Vigitron, Inc. under this warranty is limited to the original purchase price of the
Product only.
Technical Specifications*
RoHS
Drawings
Electrical
Ethernet Interface Standard 10/100BaseT
Ethernet Rate Auto Negotioates 10/100 Mb/s
Fiber Optics SFP socket
Input Power 12VDC / 48VDC (when provides PoE)
PoE 802.3af/at up to 30W
Consumption 2W maximum
Connectors SFP Interface: SFP Socket
Ethernet Interface: RJ-45 Connector
Power: Pluggable Terminal Block
Environmental
Humidity 0 to 95%, non-condensing
Temperature Operating: 0°C to +70°C
Storage: -40°C to +80°C
Mechanical
Dimensions 0.97 x 1.75 x 2.7 in., 2.46 x 4.45 x 6.86 cm (HxWxL)
Weight 0.170 lb, 77 g
Material Extruded Aluminum
Accessories
12 VDC wall-mount power supply (optional)
48 VDC wall-mount power supply (optional)
*Specifications subject to change without notice.
Ordering Information
Part No. Description
Vi5001 PoE Media converter
Vi0012 12VDC @ 12W Power Supply
Status LEDs
© Copyright 2015 Vigitron, Inc.
TEL (+1) 858 - 484 - 5209 • FAX (+1) 858 - 484 - 1205
7810 Trade Street, Suite 100, San Diego, CA 92121, USA • [email protected] • www.vigitron.com
Manual_Vi5001
Top View
Left View Right View
2.7"
1.75”
0.97"
Traffic Link
3.56"
0.9”
Mounting Pattern
SFP 10/100BaseT
PoE Media Converter
Vi5001
Power
PoE
Link/Activity
www.vigitron.com
Power
12VDC/48VDC
LED Name Color Status Function
OFF Power is OFF
ON Power is ON
OFF No PoE
ON PoE
OFF Fiber Link is OFF
YELLOW ON /
FLASHING Fiber Activity
OFF No connection
FLASHING Connection is OK with Traffic
OFF No connection
ON Connection is OK
Link
(Standard Side)
Power GREEN
PoE
Fiber Port
Traffic
(Standard Side) GREEN
YELLOW
GREEN
Vi01310MM 1310nm MM SFP (multi-mode)
Vi00850MM 850nm MM SFP (multi-mode)
Vi01310SM 1310SM SFP (single-mode)
Vi0017 48VDC @ 40W PoE Power Supply
Other Vigitron Media Converter manuals

Vigitron
Vigitron Vi50000A User manual

Vigitron
Vigitron MaxiiFiber Vi5001 User manual

Vigitron
Vigitron MaxiiFiber Vi50000U User manual

Vigitron
Vigitron MaxiiPower Vi22301 User manual

Vigitron
Vigitron MaxiiFiber Vi50004 User manual

Vigitron
Vigitron Vi5004 User manual

Vigitron
Vigitron Vi50000 User manual

Vigitron
Vigitron Maxiifiber Vi50000A User manual

Vigitron
Vigitron MaxiiFiber Vi5004 User manual