Vigitron Vi5004 User manual

Vi5004 PoE Media Converter Installation Manual
Application Drawing
Media Converter
Important Safety Warning
WARNING! - To reduce the risk of fire or electric shock, do not expose
this apparatus to rain or moisture. This apparatus shall not be exposed to
dripping or splashing and no objects filled with liquids, such as vases shall
be placed on the apparatus.
WARNING! - This apparatus is a Class I product. This product must
be connected to a mains socket outlet thru an AC to DC Power supply.
WARNING! - The mains plug is used as the disconnect device and
shall remain readily operable.
DO NOT OPEN
RISK OF ELECTRIC SHOCK
CAUTION
CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK,
DO NOT REMOVE COVER. NO USER SERVICEABLE
PARTS INSIDE. REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
IP Camera-end Installation
The Smart Choice for Transmission Solutions www.vigitron.com
Ethernet Switch/NVR-end Installation
- Connect an approved 12VDC power supply to the power connector of
Vi5004. A power adapter connector is provided to simplify connection.
- Connect the RJ45 connector of the Ethernet switch to the 10/100BaseT
Ethernet port of Vi5004 using a standard Cat5/6 cable of maximum
328 feet (100 m) in length.
- Connect one end of the long fiber optic cable to a SFP module, then
connect the SFP module to the SFP socket of Vi5001.
The Ethernet link, Fiber link, activity LEDs should be "ON" and "Blink" to
indicate the status of each port.
- Read these instructions.
- Keep these instructions.
- Heed all warnings.
- Follow all instructions.
- Do not use this apparatus near water.
- Clean only with a dry cloth.
- Install in accordance with the manufacturer’s instructions.
- This installation should be made by a qualified service person and should
conform to all local codes.
- DO NOT bundle UTP or Coax signals in the same conduit as high-voltage
wiring.
- To reduce the risk of fire or electrical shock, do not expose these products
to rain, moisture, dripping or splashing.
- No objects filled with liquids, such as vases, shall be placed on Vigitron
equipment.
- DO NOT install the unit in a place where the operating ambient tempera
ture exceeds 75° C.
- Make sure that the external power supply output voltage is in the recom
mended range.
- Do not install near any heat sources such as radiators, heat registers,
stoves or other apparatus (including DVRs) that produce heat.
- Protect the power cord from being walked on or pinched particularly at
plugs, convenience receptacles, and the point where they exit from the
apparatus.
- Only use attachments/accessories specified by the manufacturer.
- Unplug this apparatus during lightning storms or when unused for long
periods of time.
- Refer all servicing to qualified service personnel. Servicing is required
when the apparatus has been damaged in any way, such as a power
supply cord or plug is damaged, liquid has been spilled, or objects have
fallen into the apparatus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.
- The powe plug is used as the disconnect device and shall remain readily
operable.
Vigitron’s Vi5004 is a 4 channels media convertor that enables Ethernet
signals to be transmitted over different fiber optic cables UTP connections
with fiber to meet long distance transmission requirement and those where
fiber is already installed. The use of SFP fiber modules results in compat-
ibility with all major single and multimode fiber optics cables to achieve
transmission distances depending on the cable and SFP. When connected
to the Vi5001, up to 30 watts PoE can be provided to site cameras using
the Vi0017 power supply.
The Vi5004 can also be connected directly to MSA compliant SFP.
The Vi5004 is an ideal solution forconverting existing analog fiber
infrastructures to IP systems. It provides a unique, reliable, and cost
effective solution to combine a variety of transmission methods to meet any
application requirement. By using the Vi5000R, up to four Vi5004 modules
can be used to provide up to 16 channels of Ethernet copper to fiber
conversion in a rack mount configuration.
- Insert a suitable 100MBps SFP into the SFP socket of the Vi5001. The
SFP needs to match the specification of the fiber optics cable.
- Connect the fiber connector of the optical wire to the SFP.
- If the IP Camera is non-PoE use an approved 12VDC or 48VDC power
adapter to power the Vi5001.
- If the IP Camera is a PoE enabled use the Vi0017 or another approved
48VDC power adapter to power the Vi5001.
- Connect the IP camera RJ45 connector to the “10/100BaseT Ethernet” port
of Vi5001 using a standard Cat5/6 cable of maximum 100m in length.
Vi0012
Vi0017
PoE Camera
Vi3026/Vi3326
Vi5001
Fiber Data & PoE
Vi0012
Vi5004
SFP
+
SFP x4
+
Vi0017
PoE Camera
Vi3005
Vi5001
Data & PoE
Vi5004
SFP
SFP x4
+
Fiber
Vi0012

Limited Lifetime Warranty
Vigitron, Inc. warrants that all Vigitron products (“Product”), if used in accordance
with these instructions, will be free of defects in material and workmanship for
lifetime defined as the duration period of time until product end of life is announce-
ment. After which Vigitron will continue to provide warranty services for a period of 3
years. Period covering valid warranty will be determined by proof of purchase in the
form of an invoice from an authorized Vigitron dealer.
Warranty will only be provided for as long as the original end user purchaser owns
the product. Warranty is not transferrable. At Vigitron's option, defective product will
be repaired, replaced or substituted with a product of equal value. This warranty
does not apply if, in the judgment of Vigitron, Inc., the Product fails due to damage
from shipment, handling, storage, accident, abuse or misuse, or if it has been used
or maintained not conforming to Product manual instructions, has been modified, or
serial number removed or defaced. Repair by anyone other than Vigitron, Inc. or an
approved agent will void this warranty. Vigitron, Inc. shall not under any circum-
stances be liable to any person for any incidental, indirect or consequential
damages, including damages resulting from use or malfunction of the product, loss
of profits or revenues or costs of replacement goods. The maximum liability of
Vigitron, Inc. under this warranty is limited to the original purchase price of the
Product only.
Technical Specifications*
RoHS
Electrical
Ethernet Standard 10/100BaseT, Auto-Negotiation, Auto
MDI/MDI-X (x4)
Fiber Compatibility Multimode Fiber Optical Cable: 50/125um
Multimode Fiber Optical Cable: 62.5/125um
Single Mode Fiber Optical Cable: 9/125um
Distance Based on cable and SFP
Fiber Connection LC based on SFP (x4)
Connectors Fiber: SFP sockets compliant to MSA standards
Ethernet: 4 x RJ45
Power: Detachable Terminal Block
Status LED Power
Ethernet: Link/Traffic, 10/100Mbps
Fiber
Data Interfaces & RFC 768 UDP, RFC 2068 HTTP
Compliances RFC 793 TCP, RFC 791 IP
RFC 1783 TFTP, RFC 894 IP over Ethernet
RFC 2544 TCP/IP Packet Transmission
Standards IEEE 802.3 10Base-T
IEEE 802.3u 100Base-TX
IEEE 802.3af, IEEE 802.3at
Power Requirements
Input
12VDC @ 1 amp (non-PoE operation)
Regulatory
Safety CE
Environmental RoHS, WEEE
Environmental
Humidity 0 to 95%, non-condensing
Temperature Operating: 0°C to +70°C
Storage: -40°C to +85°C
Mechanical
Dimensions 1.65 x 2.69 x 4.08 in., 4.19 x 6.83 x 10.36 cm (HxWxL)
Weight 0.59lb (266g)
Ordering Information
Status LEDs
© Copyright 2015 Vigitron, Inc.
TEL (+1) 858 - 484 - 5209 • FAX (+1) 858 - 484 - 1205
7810 Trade Street, Suite 100, San Diego, CA 92121, USA • [email protected] • www.vigitron.com
Manual_Vi5001
LED Name Color Status Function
OFF Power is OFF
ON Power is ON
OFF No PoE
ON PoE
OFF Fiber Link is OFF
YELLOW ON /
FLASHING Fiber Activity
OFF No connection
FLASHING Connection is OK with Traffic
OFF No connection
ON Connection is OK
Link
(Standard Side)
Power GREEN
PoE
Fiber Port
Traffic
(Standard Side) GREEN
YELLOW
GREEN
Vi5004 4 Channel Fiber to Ethernet Convertor
Vi0012 12VDC @ 1 Amp Power Supply
Vi00850MM-H Multimode Fiber Hardened SFP
Vi01310MM-H Multimode Fiber Hardened SFP
Vi01310SM-H Single mode Fiber Hardened SFP
Vi5000B Blank Panel for Vi5000R
Vi5000R Rack Mount Holds Up to (4) Vi5004
- (16) Channels Total
Part No. Description
Table of contents
Other Vigitron Media Converter manuals

Vigitron
Vigitron Vi50000 User manual

Vigitron
Vigitron MaxiiFiber Vi5001 User manual

Vigitron
Vigitron Vi50000A User manual

Vigitron
Vigitron Maxiifiber Vi50000A User manual

Vigitron
Vigitron MaxiiPower Vi22301 User manual

Vigitron
Vigitron MaxiiFiber Vi5004 User manual

Vigitron
Vigitron MaxiiFiber Vi50004 User manual

Vigitron
Vigitron MaxiiFiber Vi50000U User manual

Vigitron
Vigitron Vi5001 User manual