Ele tri al & Gas Requirements
10
Electrical Requirements
Che k your national and lo al odes
regarding this unit. This range requires
120VAC/60 Hz; 4 ft. (121.9 m), 3-wire ord
with grounded 3-prong plug atta hed to
unit. See “Ele tri al Conne tion” se tion for
grounding instru tions. Must be fused
seperately from any other ir uit.
Gas Connection
The gas supply (servi e) line must be the
same size or greater than the inlet line of the
applian e. This range uses a 1/2” (1.3 m) ID
NPT (S h40) inlet. Sealant on all pipe joints
must be resistive to LP gas.
The ran e is desi ned specifically for
natural as or liquid propane (LP) as.
Before be innin installation verify that
the model is compatible with the intended
as supply.
Manual shut-off valve:
This installer-supplied valve must be installed
in the gas servi e line before the applian e
in the gas stream and in a lo ation where it
an be rea hed qui kly in the event of
an emergen y. Any opeing behind the range
shall be sealed.
In Massachusetts: A “T” handle type
manual valve must be installed in the gas
supply line to the applian e.
IMPORTANT: Any conversion required
must be performed by your dealer or a
qualified licensed plumber or as service
company. Please provide the servi e person
with this manual before work begins.
Pressure Re ulator:
• All heavy-duty, ommer ial type ooking
equipment must have a pressure regulator
on the in oming servi e line for safe and
effi ient operation, sin e servi e pressure
may flu tuate with lo al demand. External
regulators are not required on this range
sin e a regulator is built into ea h unit at
the fa tory. Under no ondition bypass
this built-in regulator.
• Manifold pressure should be he ked with
a manometer, natural gas requires 5.0”
W.C.P. and LP gas requires 10.0” W.C.P.
In oming line pressure upstream from the
regulator must be 1” W.C.P. higher than
the manifold pressure in order to he k
the regulator. The regulator used on this
range an withstand a maximum input
pressure of 1/2” PSI (14.0” W.C.P.). If the
line pressure is in ex ess of that amount, a
step down regulator will be required.
• The applian e must be dis onne ted from
the gas supply piping system during any
pressure testing of that system.
ELECTRICAL SHOCK
HAZARD
To void the risk of electric l
shock, person l injury or de th;
verify electric l power is turned off t the
bre ker box nd g s supply is turned off
until the r nge is inst lled nd re dy to
oper te, inst ll tion by n uthorized
inst ller only.
Flexible Connections:
If the unit is to be installed with flexible
ouplings and/or qui k-dis onne t fittings,
the installer must use a heavy-duty AGA
design- ertified flexible onne tor of at least
1/2” (1.3 m) ID NPT (with suitable strain
reliefs) in omplian e with ANSI Z21.41
and Z21.69.
In Canada: CAN 1-6, 10-88 metal
onne tors for gas applian es and CAN
1-6.9 M79 qui k dis onne t devi es for use
with gas fuel.
In Massachusetts: This applian e must be
installed with a 36” (3-foot) long flexible
gas onne tor.