6
3) Continuallycheck for foam buildup in
recoverytank. Use a distributor
recommended foam control solution.
NOTE: Excessive foam buildup will not
activate the float shut-off and may cause
damage to the vacuum motor.
4) Repeat extraction path on heavily
soiled areas.
5) If brush stops spinning, there maybe
an obstruction in the brush. Unplugthe
power cable, raise the brush off the
floor and check for an obstruction.
Check & reset the brush circuit breaker
located on the control housing.
6) When recover of the dirtysolution ends,
or the solution tank is empty,you must
drain the recoverytank. (see TANK
DRAINING)
USE OF ACCESSORY TOOLS
NOTE: Prior to cleaning upholstery, be
sure to read cleaning instructions provided
by the manufacturer.
1) Disconnect black vacuum hose off the
back right side of the machine.
Connect (optional) accessoryvacuum
hose to area where the standard
vacuum hose was removed.
2) Connect (optional) accessorysolution
hose to brass quick connect coupler
located on the back of the machine.
3) Connect (optional) accessorytool to
solution and vacuum hoses.
4) Turn on vacuum / pump switch.
5) Operate accessorytools as needed.
6) When cleaningis completed, relieve
water pressure from solution lines by
turningoff vacuum / pump switch and
then squeeze trigger for 4seconds.
DRAINING TANKS
DRAINING SOLUTION TANK
1) Disconnect vacuum hose from back of
machine and connect the bleeder”
vacuum hose (included with machine)
to the machine back.
2) Remove the solution tank filter at the
fill area and place end of bleeder”
hose into the bottom of the tank.
3) Turn on vacuum / pump switch &
vacuum out the remainingsolution.
DRAINING RECOVERY TANK
1) Turn off machine, unplugand remove
power cable.
2) Unhook drain hose off the back of the
machine and remove drain hose
stopper.
3) Drain dirtysolution into floor drain.
4) Replace drain hose stopper and
reattach hose to back ofmachine.
MACHINE MAINTENANCE
To keep the machine performingwell
for manyyears, please follow the
followingmaintenance procedures.
!!! Always confirmthat the machine
is unplugged prior to performing
any maintenance or repairs!!!
DAILY MAINTENANCE
1) When cleaningoperation is complete
for the day, drain and rinse the
recoverytank thoroughlywith clean
water.
2) Remove remainingsolution from
solution tank.
3) Remove float shut-off (pingpongball
in cage) from recoverytank and clean
with water.