Iss 1.3 Aug 2019 EVSE Protocol Controller (EPC) Manual | Viridian EV 6
Aer interlocking, the charge-enable relay P1/P2, P3/P4 or P4/P5 is acvated (see Proximity) if the vehicle is signalling state
C. The charging process is acvated, and the LED is changed to steady-green. If state D is indicated (venlaon required) then
charging and interlock are deacvated as the EPC does not provide a fan-enable mechanism, and the LED is changed to steady
-red.
In the fault condion the charge-enable P1/P2, P3/P4, or P5/P6 and the interlock are deacvated and the LED is changed to
connually blink red.
VENTILATION REQUIREMENT
WARNING: SUFFOCATION HAZARD WHEN CHARGING INDOORS
Without venlaon, a danger of suocaon can arise due to gas build-up with some baery types when charging indoors. If
the charging process takes place indoors, forced-air venlaon should be installed. The Viridian EV EPC does not monitor the
funconality of the forced-air venlaon.
PILOT CIRCUIT
The pilot circuit is used for the bi-direconal exchange of informaon between the charging staon and the vehicle. Via this
signal, the charging staon indicates to the vehicle the maximum permied charging current which the vehicle can call up. The
operaonal readiness of the charging staon is also indicated. Via this signal, the vehicle indicates to the charging staon its
current state of charging readiness.
WARNING
Via the pilot signal, the EPC module species the maximum charging current that can be called up by the vehicle. This specied
current must be consistent with the line protecon congured for the charging device and the rest of the plant conguraon.
Failure to observe this noce can result in injury to persons or property damage.
PROXIMITY
With free cable installaons the charging device detects the maximum current carrying capacity of the connected charging
cable via the proximity signal. The acvated charging output coded in the pilot signal is no greater than the current carrying
capacity of the charging cable.
To ensure that the charging current does not exceed the rated capacity of the AC main power supply, there are dierent
product variants which each provide dierent maximum charging current presets (Free/socket: 16A, 32A, and 63A. Tethered:
16A, 30A, 32A, 40A, 50A, 63A, 70A and 80A). The product version that is used must be designed corresponding to the
installed line protecon of the charging staon.
The 32A and 63A versions of the free cable Viridian EV EPC are capable of generang dierent enabling signals depending on
the current carrying capacity that is detected. For charging cables that have a current carrying capacity of 16A according to
IEC 61851, relay P1/P2 is acvated. The charging circuit that is acvated by this must be designed with a suitable line
protecon for 16A.For charging cables that have a current carrying capacity of 32A according to IEC 61851, relay P3/P4 is
acvated. The charging circuit that is acvated by this must be designed with a suitable line protecon for 32A.For charging
cables that have a current carrying capacity of 63A according to IEC 61851, relay P5/P6 is acvated. The charging circuit that
is acvated by this must be designed with a suitable line protecon for 63A.