Brodersen RTU32S Series User manual

R
TU32S
RTU32S Series – Small Compact Utility RTU
Installation and Wiring Guide
Version 1.03 / Nov. 2016 / DOC 40350

RTU32S Installation and Wiring Guide
rodersen A/S, Islevdalvej 187, DK-2610 Roedovre, Denmark, Tel: +45 45 35 26 27, Fax: +45 45 35 26 29, Email: sales@brodersen.com
2
Contents
1. Customer Information...........................................................................................................................................................3
2. Introduction ..........................................................................................................................................................................5
3. General Information..............................................................................................................................................................6
4. Installation ..........................................................................................................................................................................11
5. Mounting instruction ..........................................................................................................................................................12
6. Wiring details and diagrams ...............................................................................................................................................12
7. I/O Expansion Modules ......................................................................................................................................................17
8. Display and Keys................................................................................................................................................................18
9. How to Remove the SD Flash Disc ....................................................................................................................................19
10. Configuration of the RTU.................................................................................................................................................20
11. Maintenance......................................................................................................................................................................20
12. Safety and Precautions......................................................................................................................................................21
13. Accessories .......................................................................................................................................................................22
14. Other RTUs in the Brodersen RTU32 Series family ........................................................................................................22

RTU32S Installation and Wiring Guide
rodersen A/S, Islevdalvej 187, DK-2610 Roedovre, Denmark, Tel: +45 45 35 26 27, Fax: +45 45 35 26 29, Email: sales@brodersen.com
3
1. Customer Information
Copyrig t Notice
Copyright 2014 rodersen A/S, ALL RIGHTS ESERVED.
No part of this document may be reproduced, copied, translated, or transmitted in any form or by any means,
electronic or mechanical, for any purpose, without the prior written permission of the original manufacturer.
Trademark Acknowledgement
rand and product names are trademarks or registered trademarks of their respective owners.
Disclaimer
rodersen A/S reserves the right to make changes, without notice, to any product, including circuits and/or software described or
contained in this manual in order to improve design and/or performance. rodersen A/S assumes no responsibility or liabilities for
the use of the described product(s), conveys no license or title under any patent, copyright, or mask work rights to these products,
and makes no representations or warranties that these products are free from patent, copyright, or mask work right infringement,
unless otherwise specified. Applications that are described in this manual are for illustration purposes only.
rodersen A/S makes no representation or warranty that such application will be suitable for the specified use without further
testing or modification.
Life Support Policy
RODERSEN A/S's PRODUCTS ARE NOT FOR USE AS CRITICAL COMPONENTS, IN LIFE SUPPORT DEVICES OR SYSTEMS
WITHOUT THE PRIOR WRITTEN APPROVAL OF RODERSEN A/S.
As used herein:
1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into body, or (b) support or
sustain life and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can
be reasonably expected to result in significant injury to the user.
2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to
cause the failure of the life support device or system, or to affect its safety or effectiveness.
Brodersen Customer Services
Your satisfaction is our primary concern. Here is a guide to rodersen customer services. To ensure you get the full benefit of our
services, please follow the instructions below carefully.
Tec nical Support
We want you to get the maximum performance from your products. So if you run into technical difficulties, we are here to help. For
the most frequently asked questions, you can easily find answers in the product documentation. These answers are normally a lot
more detailed than the ones we can give over the phone. So please consult this manual first.
To receive the latest version of the user manual, please visit our Web site at: http://www.brodersen.com .
Choose the product in question under product search and under each product you will find accompanying data sheets, manuals,
user guides, etc.
If you still cannot find the answer, gather all the information or questions that apply to your problem, and with the product close at
hand, call your dealer. Our distributors are well trained and ready to give you the support you need to get the most from your
rodersen products. In fact, most problems reported are minor and are able to be easily solved over the phone.
In addition, technical support is available from rodersen engineers every business day. We are always ready to give advice on
application requirements or specific information on the installation and operation of any of our products. Please do not hesitate to
call or e-mail us on [email protected].
Denmark:
rodersen A/S
Islevdalvej 187
DK-2610 Roedovre
Tel.: +45 45 35 26 27
Fax: +45 45 35 26 29
www.brodersen.com

RTU32S Installation and Wiring Guide
rodersen A/S, Islevdalvej 187, DK-2610 Roedovre, Denmark, Tel: +45 45 35 26 27, Fax: +45 45 35 26 29, Email: sales@brodersen.com
4
Product Warranty
rodersen warrants to you, the original purchaser, that each of its products will be free from defects in materials and workmanship
for two years from the date of purchase.
This warranty does not apply to any products which have been repaired or altered by persons other than repair personnel
authorized by rodersen, or which have been subject to misuse, abuse, accident or improper installation. rodersen assumes no
liability under the terms of this warranty as a consequence of such events. ecause of rodersen’s high quality control standards
and rigorous testing, most of our customers never need to use our repair service. If a rodersen product is defective, it will be
repaired or replaced at no charge during the warranty period. For out-of-warranty repairs, you will be billed according to the cost of
replacement materials, service time, and freight. Please consult your distributor for more details. If you think you have a defective
product, follow these steps:
1. Collect all the information about the problem encountered. (For example, Product type and s/n, hardware and software version
etc.) Note anything abnormal and describe the error in a product failure report.
2. Call your distributor and describe the problem. Please have your manual, product, and any helpful information readily available.
3. If your product is diagnosed as defective, make arrangement with your distributor about this.
4. Carefully pack the defective product, a complete failure report and a photocopy of proof of purchase date (such as your sales
receipt) in a shippable container. A product returned without proof of the purchase date is not eligible for warranty service.
5. Ship it to your distributor.

RTU32S Installation and Wiring Guide
rodersen A/S, Islevdalvej 187, DK-2610 Roedovre, Denmark, Tel: +45 45 35 26 27, Fax: +45 45 35 26 29, Email: sales@brodersen.com
5
2. Introduction
This equipment is designed and manufactured to conform to the following EC standards:
EN55011: Class A EN55022: Class A
EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8
EN61000-4-11
EN61000-3-2 EN61000-3-3
EN60950 Safety of information technology equipment
Failure to use the equipment in the manner described in the product literature will invalidate the warranty.
A 'Declaration of Conformity' statement to the above standards, and a list of auxiliary equipment used for compliance verification,
is available on request.
This product must be disposed of in accordance with the WEEE directive.

RTU32S Installation and Wiring Guide
rodersen A/S, Islevdalvej 187, DK-2610 Roedovre, Denmark, Tel: +45 45 35 26 27, Fax: +45 45 35 26 29, Email: sales@brodersen.com
6
3. General Information
Tec nical Specification Summary
Mec anical
Enclosure: Aluminium enclosure for DIN rail mounting
Dimensions (H x W x D): 80mm x 178 x 80mm (excl. connectors)
Weight: 0.8kg (approx.)
Environmental
Temperature: −20°C to +60°C (operation)
Humidity Range: 0% to 95% Non-condensing
IP rating: IP20
Embedded I/Os
•Section A / Digital Inputs
Channels: 8 x digital input
Connection: 10 pin removable screw terminals
Position: RTU top left
Available on: 28IO, 42IO and 16DIO versions
•Section B / Digital Inputs
Channels: 8 x digital input
Connection: 10 pin removable screw terminals
Position: RTU top middle
Available on: 28IO, 42IO and 16DIO versions
•Section C / Digital Outputs
Channels: 8 x digital output
Connection: 10 pin removable screw terminals
Position: RTU bottom left
Available on: 28IO, 42IO and 16DIO versions
•Section D / Analog Inputs
Channels: 4 x analog input (28IO and 42IO versions) or 8 x digital output (16DIO version)
Connection: 10 pin removable screw terminals
Position: RTU bottom middle
Available on: 28IO, 42IO and 16DIO versions
•Section E / Extended IOs
Channels: 8 x configurable digital input/output
Connection: 10 pin removable screw terminals
Position: RTU top right
Available on: 42IO version
•Section F/ Extended IOs
Channels: 2 x analog input + 4 x fast digital/32-bit counter input
Connection: 10 pin removable screw terminals
Position: RTU bottom right
Available on: 42IO version
I/O C aracteristics
•Digital Inputs
Input Range: Standard: 10 to 30VDC, others on request
Isolation: 2KV Opto-isolated
Available on: 28IO, 42IO and 16DIO versions
•Digital Outputs
Input Range: Standard: 10 to 30VDC, others on request
Output switch type: Smart high side switch (28IO and 42IO versions) or Transistor PNP (16DIO version)

RTU32S Installation and Wiring Guide
rodersen A/S, Islevdalvej 187, DK-2610 Roedovre, Denmark, Tel: +45 45 35 26 27, Fax: +45 45 35 26 29, Email: sales@brodersen.com
7
Maximum Current/output: 0.5A
Protections
- Short-circuit: Yes (only for 28IO and 42IO versions)
- Overload: Yes (only for 28IO and 42IO versions)
- Overvoltage: Yes (only for 28IO and 42IO versions)
- Over temperature: Yes (only for 28IO and 42IO versions)
- Wrong connections: Yes (only for 28IO and 42IO versions)
Absolute maximum ratings: Supply voltage: 40V
Isolation: 2KV Opto-isolated
Available on: 28IO, 42IO and 16DIO versions
•Analog Inputs
Input Range: Current mode: 0 to 20mA, -20mA to +20mA, 4mA to 20mA (configurable)
Voltage mode: 0 to 10V, 0 to 5V, -5V to +5V, -10V to +10V (configurable)
Mode selection: y on-board jumpers for each channel
(set jumper: current mode, remove jumper: voltage mode)
Resolution: Effective: 16 bit
ADC: 24 bit
Accuracy: At 25°C: ±0.1%
Input impedance: Current mode: 125 Ohm ±0.1%
Voltage mode: More than 1MΩ
Linearity: > ± 0.001%
Temperature Stability: > ± 25ppm/°C (typical)
Common mode voltage: Max. ±80V DC
CMRR: Min. 80d
Power Freq. noise rejection: Standard: 50Hz
On request: 60Hz (set by manufacturer)
Digital Low-pass filter: Yes (configurable)
Absolute maximum ratings: Current: ±40mA
Voltage: ±40V DC
Isolation: Input to electronics: at least 350V
Channel to channel: at least 350V
Available on: 28IO and 42IO versions
•Fast digital / 32-bit Counter Inputs
Input Range: Standard: 5 to 30VDC, others on request
Maximum frequency: up to 5 KHz
Isolation: 2KV Opto-isolated
Available on: 42IO version
External I/O Expansion Ports
Quantity: 1
Data us: Localbus
Maximum I/O modules: 12
Connection: RJ45 Socket
Position: RTU top
IP Networking
Type: Ethernet
Number of Ethernet Ports: 1 x 10/100 ASE-Tx Ethernet
Connection: RJ45 Socket
Position: RTU top
Communications protocols: See data sheet
COM ports
Quantity: 3
Data us: Multiple – see data sheet
Connection: COM1 & COM3: D-sub 9 pin male,
COM2: 3 way screw terminal
Position: RTU top

RTU32S Installation and Wiring Guide
rodersen A/S, Islevdalvej 187, DK-2610 Roedovre, Denmark, Tel: +45 45 35 26 27, Fax: +45 45 35 26 29, Email: sales@brodersen.com
8
Mains Power Supply
•
Power Supply
version 05
Power Supply: 10-30 VDC
Power Consumption: 4-12W depending on configuration and connected I/O expansion modules
Connection: Removable screw connector – 3 wires (+, -, Gnd)
Position: RTU top left
•Power Supply version 10
Power Supply: 90-265V AC/DC
Power Consumption: 4-12W depending on configuration and connected I/O expansion modules
Connection: Removable screw connector – 3 wires (+, -, Gnd)
Position: RTU top left
•
Power Supply
version 30
Power Supply: 20-60 VDC
Power Consumption: 4-12W depending on configuration and connected I/O expansion modules
Connection: Removable screw connector – 3 wires (+, -, Gnd)
Position: RTU top left

RTU32S Installation and Wiring Guide
rodersen A/S, Islevdalvej 187, DK-2610 Roedovre, Denmark, Tel: +45 45 35 26 27, Fax: +45 45 35 26 29, Email: sales@brodersen.com
9
RTU Front Panel
Figure 1: RTU32S Front Panel
Front Panel LCD and Keys
On the RTU32S front panel, there are a LCD display and 4 keys. Important statuses of the RTU32S, including statuses of communication
buses and I/O ports are shown on the LCD display. The displayed parameter on the LCD can be changed by the keys
RTU Top Panel
Figure 2: RTU32S Top Panel
Top Panel Indicators Description
COM1: Indicating Rx/Tx activity on COM1.
COM2: Indicating Rx/Tx activity on COM2.
COM3: Indicating Rx/Tx activity on COM3.
CPU: Indicating power on RTU/CPU.
LAN1: LAN connector green LED indicate network connected and yellow indicate Rx/Tx traffic.

RTU32S Installation and Wiring Guide
rodersen A/S, Islevdalvej 187, DK-2610 Roedovre, Denmark, Tel: +45 45 35 26 27, Fax: +45 45 35 26 29, Email: sales@brodersen.com
10
RTU Interfaces and Connectors
Figure 3: RTU32S Top Panel Interfaces and Connectors
Figure 4: RTU32S Front Panel Interfaces and Connectors
Figure 5: SD Flash card
Port Name Connector Functions
Power supply input 3 way removable screw terminal Power Supply Input
LAN 1 RJ45 Socket IP Network Connections
Local us I/O Port RJ45 Socket rodersen Local us port
COM1, COM3 D-sub 9pin Male Serial interfaces
COM2 3 way removable screw terminal Serial interface
US 1 & 2 US socket for Type A connector External Connection
I/Os 10 ways removable screw terminals Industrial I/O interfaces
SD Flash SD card interface slot Software Flash disc slot
Power Supply
Input
LAN1 / Ethernet
US 1 & US 2
COM1 RS232 Full
handshake
COM2 RS232
COM3 RS232
Local us RJ45
(I/O Expansion)
Industrial digital and analog I/Os Expanded I/Os
(for optional additional I/Os)
SD Flash card
behind cover

RTU32S Installation and Wiring Guide
rodersen A/S, Islevdalvej 187, DK-2610 Roedovre, Denmark, Tel: +45 45 35 26 27, Fax: +45 45 35 26 29, Email: sales@brodersen.com
11
4. Installation
Equipment and Tool Requirements
•The RTU32S unit
•A small flat-bladed screwdriver.
•A pair of wire cutters/strippers.
•A standard panel / cabinet with DIN rail with space for mounting and wiring RTU32S and any I/O Expansion modules, modems,
additional power supplies, terminals, fuses etc. required.
External Cabling Requirements
Connection Termination and Suggested Type
Power supply input AC Mains: Normal standard mains cabling installation. Current rating
to suit particular installation.
DC: 1.5mm² wire with ferules.
Earth: Earth wiring must be 2,5mm² and kept as short as possible.
Ethernet Port Cabling connector: RJ45 Socket
Standard unscreened LAN cable
Expansion Local us Cabling connector: RJ45 Socket.
Special rodersen UCC-5xx Local us cable
I/O terminals and COM2 Cables max 1.5mm²
COM1 and COM3 ports RS232 Standard Null-Modem or Modem cables
US 1 & 2 Shielded US cable recommended for Modems
Recommended Installation Procedure
•Please read and observe the instructions and guidelines in Section “Safety and Precautions” prior to installation. Failure to follow
these instructions and guidelines may cause personal injury and/or damage to the equipment.
•Fit the RTU32S unit and any additional I/O Expansion modules to a panel or cabinet with pre-mounted DIN rail.
•Ensure that there is space available for mounting comms cables like D-sub connectors on the top panel of the RTU32S.
•Connect the wiring for digital and analogue input ports, digital output ports, expansion bus, COM ports, US ports and Ethernet
port to the connectors according to the application.
•Connect ground cabling and the power supply cabling (as appropriate) to the power supply connector.

RTU32S Installation and Wiring Guide
rodersen A/S, Islevdalvej 187, DK-2610 Roedovre, Denmark, Tel: +45 45 35 26 27, Fax: +45 45 35 26 29, Email: sales@brodersen.com
12
5. Mounting instruction
The RTU is mounted on a 35mm DIN-rail (EN50022). For mounting and de-mounting - see the figures below.
Figure 6: Mounting procedure Figure 7: De-mounting procedure
NOTE: ALWAYS MOUNT RTU HORISONTAL!
6. Wiring details and diagrams
Wiring - general
•Terminal blocks for I/O and power supply are plug-in connectors with screw terminals. It is recommended to use ferrules on
wires.
•LAN and Local us are RJ45 - Note: e careful to connect correctly. If a network interface cable is connected to the Local us
interface the PC, switch, router or other network equipment it will most likely be damaged.
•COMs are 9 pole sub-D male connectors and a 3 pole screw connector.
•The wiring diagrams cover all versions of the RTU32S variants. For RTU32S version without I/O this section is still relevant as it
include wiring details for supply voltage and comms interfaces.
Wire size
Earth and power supply: max. 2.5mm² (earth wiring must be 2.5mm² and kept as short as possible).
Other connectors: Max. 1.5mm² with ferrules.
Wiring diagrams
Power Supply
Version 10 (Main Supply) Version 05 and 30 (VDC Supply)
Figure 8: Power supply wiring diagram
Earth connects to PE conductor - wire as short as possible.

RTU32S Installation and Wiring Guide
rodersen A/S, Islevdalvej 187, DK-2610 Roedovre, Denmark, Tel: +45 45 35 26 27, Fax: +45 45 35 26 29, Email: sales@brodersen.com
13
Power supply version 05:
+: +12-24V DC positive
-: 0V negative
Power supply version 10:
L: 115-230VAC Mains supply
N: 0V Mains supply (neutral).
Power supply version 30:
+: +24-48V DC positive
-: 0V negative
Digital Input Wiring
All digital input channels are equipped with optocouplers. To activate the inputs an external voltage is required. All Inputs are
additional used for S0 counter inputs.
Figure 9: Digital input wiring diagram
Note: Common ( C ) is NOT internally connected between the sections. It means that C must be connected to “minus” for each section.
Digital Output Wiring
Each digital output channel includes a smart high side switch and equipped with optocouplers. Output current is maximum 0.5A per
channel. All outputs are short-circuit, overload, overvoltage, over temperature and wrong connections protected.
Figure 10: Digital output wiring diagram
External Supply
10
-
30VDC
External Supply
10
-
30VDC

RTU32S Installation and Wiring Guide
rodersen A/S, Islevdalvej 187, DK-2610 Roedovre, Denmark, Tel: +45 45 35 26 27, Fax: +45 45 35 26 29, Email: sales@brodersen.com
14
Analogue Input Wiring
Each analog input channel is individually isolated from each other and from other electronics (CPU, Local us and etc.). Current or
voltage mode is selected for each channel individually by setting or removing dedicated jumpers on the boards. The jumpers are
located on the I/O board, beside the output of each channel (for AI0-AI4), and also on the extended board, if available (in 42IO version
for extended AIs). For each channel, the related jumper should be set for current mode, or should be removed for voltage mode.
Figure 11: Current/Voltage mode selection jumpers (for AI0-AI3)
Figure 12: Current/Voltage mode selection jumpers in extended board
(for extended AIs)
For each channel in each mode, the values for input range and filter are configured through web-based configurator and/or WorkSuite
configuration (details are provided in RTU User Guides).
Figure 13: Analog input wiring diagram
Note: The shield must be connected to the common terminal ( C ).
Current/Voltage mode
selection jumpers
Channels 0 and 3: current mode
Channel 2: voltage mode
Current/Voltage mode
selection jumpers

RTU32S Installation and Wiring Guide
rodersen A/S, Islevdalvej 187, DK-2610 Roedovre, Denmark, Tel: +45 45 35 26 27, Fax: +45 45 35 26 29, Email: sales@brodersen.com
15
Extended IOs Wiring
Type of these I/Os are not fixed and could be varied according to the I/O card (I/O plug-in expansion card) version.
For 42IO version, the type of these I/Os are 8 channels configurable digital inputs/outputs on section E, and 2 channels analog inputs
plus 4 channels fast digital / 32-bit counter inputs on section F.
Each channel of Configurable digital I/Os can be configured as digital input or digital output through web-based configurator and/or
WorkSuite configuration (details are provided in RTU User Guides).
Figure 14: Expanded IOs
For 42IO version, pin assignment of the expanded I/Os (on section E and section F connectors) are described in the following tables:
Expanded IOs / Section E
Expanded IOs / Section F
Pin Name Description
Pin Name Description
1 - (or C) Negative power supply (or common)
1 AI4+ Analog input channel 4, positive input
2 DIO0 Configurable digital I/O channel 0
2 AI4- Analog input channel 4, negative input
3 DIO1 Configurable digital I/O channel 1
3 AI5+ Analog input channel 5, positive input
4 DIO2 Configurable digital I/O channel 2
4 AI5- Analog input channel 5, negative input
5 DIO3 Configurable digital I/O channel 3
5 Com0,1 Common for digital/counter input channels 0 & 1
6 DIO4 Configurable digital I/O channel 4
6 CI0 Digital/counter input channel 0
7 DIO5 Configurable digital I/O channel 5
7 CI1 Digital/counter input channel 1
8 DIO6 Configurable digital I/O channel 6
8 CI2 Digital/counter input channel 2
9 DIO7 Configurable digital I/O channel 7
9 CI3 Digital/counter input channel 3
10 + Positive power supply
10 Com2,3 Common for digital/counter input channels 2 & 3
Characteristics and wiring diagrams for all digital and analog I/O channels of the expanded IOs are the same as the other I/Os described
before. Digital/counter inputs group 1 (CI0 and CI1) and digital/counter inputs group 2 (CI2 and CI3) are electrically isolated from each
other (equipped with optocouplers with separated commons for each group).
Note 1: Common or negative pin of Configurable digital I/Os on section E of expanded IOs ( - or C ) is NOT internally connected to the
common or minus of the other sections.
Note 2: Commons for Digital/counter input channels ( Com0,1 and Com2,3 ) are NOT internally connected. It means that they must be
connected to “minus” separately. In other words, if COM0,1 is connected to the minus and COM2,3 is not connected, only CI0 and CI1
will work according to their applied signals, and CI2 and CI3 will not work.
Interface COM1 wiring – RS232 wit full ands ake
RS232 port connector (9 pole sub-D - male). The wiring is standard V.24 RS232 wiring.
Pin no Signal Description/Remarks Input / Output
1 DCD Data carrier detect Input
2 RX Receive data Input
3 TX Transmit data Output
4 DTR Data terminal ready Output
5 SG Signal ground GND

RTU32S Installation and Wiring Guide
rodersen A/S, Islevdalvej 187, DK-2610 Roedovre, Denmark, Tel: +45 45 35 26 27, Fax: +45 45 35 26 29, Email: sales@brodersen.com
16
6 DSR Data set ready Input
7 RTS Request to send Output
8 CTS Clear to send Input
9 RI Ringing indicator Input
Interface COM2 wiring – RS232
3 way removable screw connector.
Figure 15: COM2 connector
Pin no Signal Description/Remarks Input / Output
1 SG Signal ground GND
2 RX Receive data Input
3 TX Transmit data Output
Interface COM3 wiring – RS232
RS232 port connector (9 pole sub-D - male)
Pin no Signal Description/Remarks Input / Output
1 NC Not used -
2 RX Receive data Input
3 TX Transmit data Output
4 NC Not used -
5 SG Signal ground GND
6 NC Not used -
7 NC Not used -
8 NC Not used -
9 NC Not used -
Et ernet
Ethernet interface connector: RJ45 10/100 ASE-Tx Fast Ethernet compatible.
It is recommended to use shielded network cables. And note that if you connect your PC directly to the LAN1 interface, you may need
to use cross-wired network cable (if your PC Ethernet interface do not support auto switching Rx/Tx).
Factory settings for LAN1:
-IP: 192.168.0.1
-Subnet: 255.255.255.0
Dual USB
Dual US interface type 2.0. Use UCM-9x modem always in US 2 connector.
LocalBus RJ45
Local us RJ45 connector for rodersen I/O expansion modules. The Local us provide also support also power supply to I/O Expansion
modules. NOTE that load is limited to 600mA@12VDC. Consult data sheet for details.

RTU32S Installation and Wiring Guide
rodersen A/S, Islevdalvej 187, DK-2610 Roedovre, Denmark, Tel: +45 45 35 26 27, Fax: +45 45 35 26 29, Email: sales@brodersen.com
17
7. I/O Expansion Modules
I/O Expansion modules are mounted next to the RTU and connected via a Local us cable (type UCC-5xx). Maximum 12 I/O Expansion
modules can be connected and the RTU32S. Internal supply can only supply 600mA@12VDC to the I/O configuration. If the required
I/O modules exceed a total use of 600mA then an additional power supply must be added. Additional power suppliers are UCS-53.924
for 12-48VDC and UCS-54.230 for 230VAC.
Figure 16: RTU32S with 8AI Expansion module
Figure 17: RTU32S with multiple Expansion modules and additional power supply
Wiring of IO Expansion modules – see module data sheet.
NOTE: DO NOT USE STANDARD PATCH OR NETWORK CABLE TO CONNECT I/O MODULES. IT WILL DAMAGE THE LOCALBUS
INTERFACES ON BOTH THE RTU AND THE I/O EXPANSION MODULE. ONLY USED UCC-5xx CABLES.

RTU32S Installation and Wiring Guide
rodersen A/S, Islevdalvej 187, DK-2610 Roedovre, Denmark, Tel: +45 45 35 26 27, Fax: +45 45 35 26 29, Email: sales@brodersen.com
18
8. Display and Keys
On the RTU32S front panel, there are a LCD display and 4 keys. Important statuses of the RTU32S, including statuses of communication
buses and I/O ports are shown on the LCD display. The displayed parameter on the LCD can be changed by the keys.
Figure 18: Display and Keys on the RTU32S Front Panel
After power up, the backlight of the LCD is ON and all parameters are shown sequentially, in this way that a parameter is shown for
about one second and then it changes to another parameter, and it will continue in the same way. In this mode, only “Enter” key is
worked and the other keys are not functional. y pressing “Enter”, the parameter which is showed on the LCD is fixed to display and is
not changed to another parameter. In this mode, the displayed parameter can be changed by “Up” and “Down” keys. Also, by pressing
“Esc” key, the LCD returns to the primary mode which displays all parameters sequentially.
When the backlight of the LCD goes ON, it will be turned down automatically after one minute if no key has been pressed. When the
backlight is OFF, it will be turned on by hitting each key.
In the following pictures, some examples of displayed values and statuses on the LCD display are illustrated.
Figure 19: Some examples of displayed values and statuses on the LCD Display

RTU32S Installation and Wiring Guide
rodersen A/S, Islevdalvej 187, DK-2610 Roedovre, Denmark, Tel: +45 45 35 26 27, Fax: +45 45 35 26 29, Email: sales@brodersen.com
19
9. How to Remove t e SD Flas Disc
The SD card includes the PLC runtime application files and optional driver files. If you want to delete a PLC runtime application with
code that i.e. freeze the RTU32S, you can remove it from the SD card and then the RTU will start with default PLC application “Empty”.
When you need to remove or replace the flash disc, you must be very careful and follow these instructions:
-It is recommended to dismount the RTU32S from the DIN rails to get easier access to the SD card slot.
-Find on the bottom panel the cover locked by a screw.
-Release the screw by one single turn to unlock the cover.
-Release the cover by pressing it gently forwards against the front of the RTU and open it up.
-Release the SD card by pressing it once and take it out – and note the orientation of the card connection terminals.
Install the SD card again by following these instructions:
-Insert the SD card by pressing it into the slot gently once and make sure that it is locked. Note the orientation of the card
connection terminals should be facing against the front of the RTU at mounting.
-Mount the cover by closing it over the lock screw using the “hinges”.
-Now press the cover against the back of the RTU and tighten the lock screw to lock the cover.
-The SD Card is now safely in place again and you can mount and power up the RTU again.

RTU32S Installation and Wiring Guide
rodersen A/S, Islevdalvej 187, DK-2610 Roedovre, Denmark, Tel: +45 45 35 26 27, Fax: +45 45 35 26 29, Email: sales@brodersen.com
20
10. Configuration of t e RTU
The RTU is configured in 2 steps:
1. asic settings are configured with your browser. Connect your PC to LAN1 and configure your PC to communicate with RTU32S.
2. Application programming, driver configuration and control of IO’s is done with a PC running rodersen WorkSuite package.
Please read the RTU32S User Guide carefully before starting configuration.
11. Maintenance
Under operation no special product specific maintenance measures are required.
Internal battery supporting the RTC and IOS have a lifetime of minimum 5 years when RTU32S is not connected to power supply.
When RTU is running the RTC and IOS are NOT powered by battery.
In general we recommend that you keep the RTU32S free from dust and moisture and periodically ensure the all ventilation holes are
free and not covered by any means.
Other manuals for RTU32S Series
1
Table of contents
Other Brodersen Controllers manuals