manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Vista
  6. •
  7. Outdoor Light
  8. •
  9. Vista 6216 Landscape Series User manual

Vista 6216 Landscape Series User manual

FOR USE ONLY WITH LOW VOLTAGE LANDSCAPE POWER UNITS THAT DO NOT EXCEED 25 AMPS, 15 VOLT MAXIMUM.
WARNING: Luminaires must be installed in accordance with the National Electrical Code (NEC) and local codes. Failure to do so will void the warranty and may
result in serious injury and/or damage to the luminaire.
SAFETY WARNING: Luminaire can become very hot depending on lamp wattage used. Lens and metal around lamp can become hot enough to blister hands.
Particular care should be taken not to locate luminaires where small children can reach them if high wattage lamps are used.
LUMINAIRES ARE NOT TO BE INSTALLED WITHIN 10 FT. (3.05M) OF A POOL OR SPA. SECONDARY CABLE IS NOT TO BE BURIED MORE THAN 6”.
WHEN USING MULTIPLE LUMINAIRES, LOAD IS NOT TO EXCEED THE TOTAL WATTS OF TRANSFORMER RATING. DO NOT USE EXTENSION CORDS
ON POWER UNITS.
NOTE: Always use UL recognized wire connectors for connections.
LUMINAIRE IS UL LISTED FOR ABOVE GROUND INSTALLATION ONLY.
1625 Surveyor Avenue • Simi Valley, CA 93063 • (805) 527-0987 • (800) 766-VISTA (8478)
FAX: (888) 670-VISTA (8478) • [email protected] • www.vistapro.com
Vista Professional Outdoor Lighting reserves the right to modify the design and/or construction of the fixture shown without further notification.
Stem
Main supply cable
Ground stake
Shade
Silicone filled safety
connectors
36” Pigtail
Path & Spread Lights
Landscape Series
6216
INSTALLATION INSTRUCTIONS - For T3-LED & T3-Halogen
WARNING - TO REDUCE THE RISK OF FIRE, OR INJURY TO PERSONS:
1. Turn off/unplug and allow to cool before replacing lamp.
2. Lamps get hot! Contact only switch/plug when turning on.
3. Do not touch hot lens, guard or enclosure.
4. Keep lamp away from material that may burn.
6. Do not operate luminaire fitting with a missing or damaged cover.
IMPORTANT SAFETY INSTRUCTIONS - THE LIGHTED LAMP IS HOT!
SAVE THESE INSTRUCTIONS (Leave with property owner/manager)
See Reverse for Fixtures with
Integrated LED Module
LUMINAIRE MOUNTING:
1. To prevent electrical shock, disconnect transformer from electrical supply
before installation or service.
2. Run wire pigtail from luminaire through mounting hole in top of ground
stake.
3. Thread luminaire into threaded hole in ground stake.
4. Place stake in desired position and insert into ground until ange of stake is
ush to grade.
5. Strip two leads from luminaire pigtail. Using two silicone filled safety
connectors (provided), connect leads from luminaire to main supply cable
leads.
NOTE: Luminaires are supplied with 36” of 18-2 cable pigtail for secure
connection to main supply cable. Wire is to be protected by routing in close
proximity to luminaire. Wiring should be buried a maximum depth of 6 inches
(15.2 cm) in order to connect to main supply cable.
6. Provide power to luminaire and check for proper operation.
NOTE: All luminaires orientation must be so that every part of the lampholder
and the lamp are greater than 2” from the ground plane.
LAMP INSTALLATION/REPLACEMENT:
CAUTION: Do not exceed maximum wattage marked on luminaire label.
1. To prevent electrical shock, disconnect transformer from electrical supply
before service.
2. Loosen lock fastener.
3. Remove shade.
4. Replace lamp with correct wattage and type marked on xture label.
NOTE: DO NOT touch lamp with bare hands. Use soft cloth to handle lamp.
5. Re-install shade.
6. Turn lock fastener to lock position.
NOTE: Halogen lamps must be protected from moisture and dust at all times.
Always re-install shade and lens when moved.
TO OPEN PRESS DOWN &
QUARTER TURN COUNTERCLOCKWISE
TO LOCK PRESS DOWN &
QUARTER TURN CLOCKWISE
1625 Surveyor Avenue • Simi Valley, CA 93063 • (805) 527-0987 • (800) 766-VISTA (8478)
FAX: (888) 670-VISTA (8478) • [email protected] • www.vistapro.com
Vista Professional Outdoor Lighting reserves the right to modify the design and/or construction of the fixture shown without further notification.
SPRING LOADED
LOCKING PIN
FIXTURE TOP
LOCKING RING
MALE CONNECTOR
FIXTURE BASE
FIELD REPLACEABL
E
LED ENGIN
E
FEMALE CONNECTOR
SPT-1 CABLE
LOCKING PIN IN UNLOCKED POSITION
.
ROTATE 90° CLOCKWISE TO LOCK.
PRISMATIC HIGH-IMPACT
POLYCARBONATE LENS
The operating voltage range for this LED luminaire is 6 - 15 volt AC. The Vista electronic driver ensures the LED operates at the intended lumen output while
receiving voltage as low as 6 volts, and as high as 15 VAC, resulting in a balanced lumen output from the rst xture to the last. Eliminating the dimness issues
often attributed to voltage drop.
Note: Operating voltage range for LED luminaries will vary depending on model, style and total number of LEDs. To help determine the operating
voltage range for each Vista luminaire, always consult factory’s specification sheet and/or installation instructions before installation.
6216 (07/14)
Stem
Main supply cable
Ground stake
Shade
Silicone filled safety
connectors
36” Pigtail
Path & Spread Lights
Landscape Series
6216
FOR USE ONLY WITH LOW VOLTAGE LANDSCAPE POWER UNITS THAT DO NOT EXCEED 25 AMPS, 15 VOLT MAXIMUM.
WARNING: Luminaires must be installed in accordance with the National Electrical Code (NEC) and local codes. Failure to do so will void the warranty and may
result in serious injury and/or damage to the luminaire.
SAFETY WARNING: Luminaire can become very hot depending on lamp wattage used. Lens and metal around lamp can become hot enough to blister hands.
Particular care should be taken not to locate luminaires where small children can reach them if high wattage lamps are used.
LUMINAIRES ARE NOT TO BE INSTALLED WITHIN 10 FT. (3.05M) OF A POOL OR SPA. SECONDARY CABLE IS NOT TO BE BURIED MORE THAN 6”.
WHEN USING MULTIPLE LUMINAIRES, LOAD IS NOT TO EXCEED THE TOTAL WATTS OF TRANSFORMER RATING. DO NOT USE EXTENSION CORDS
ON POWER UNITS.
NOTE: Always use UL recognized wire connectors for connections.
LUMINAIRE IS UL LISTED FOR ABOVE GROUND INSTALLATION ONLY.
See Reverse for Fixtures with
T3-LED or T3-Halogen
INSTALLATION INSTRUCTIONS - For Integrated LED Module
LED ENGINE INSTALLATION/REPLACEMENT:
1. To prevent electrical shock, disconnect transformer from electrical supply
before service.
2. Disengage spring loaded locking pins.
3. Remove shade and lens assembly to expose LED engine.
4. Remove stainless steel locking/expansion ring.
5. Pull up field replaceable LED engine assembly.
6. Disconnect connector assembly.
7. Connect new eld replaceable LED engine to connector assembly.
8. Reinstall LED engine and secure with stainless steel locking/expansion ring.
9. Reinstall shade assembly and secure spring loaded locking pins.
LUMINAIRE MOUNTING:
1. To prevent electrical shock, disconnect transformer from electrical supply
before installation or service.
2. Run wire pigtail from luminaire through mounting hole in top of ground
stake.
3. Thread luminaire into threaded hole in ground stake.
4. Place stake in desired position and insert into ground until ange of stake is
ush to grade.
5. Strip two leads from luminaire pigtail. Using two silicone filled safety
connectors (provided), connect leads from luminaire to main supply cable
leads.
NOTE: Luminaires are supplied with 36” of 18-2 cable pigtail for secure
connection to main supply cable. Wire is to be protected by routing in close
proximity to luminaire. Wiring should be buried a maximum depth of 6 inches
(15.2 cm) in order to connect to main supply cable.
6. Provide power to luminaire and check for proper operation.
NOTE: All luminaires orientation must be so that every part of the lampholder
and the lamp are greater than 2” from the ground plane.

Other Vista Outdoor Light manuals

Vista T3-LED User manual

Vista

Vista T3-LED User manual

Vista Architectural 1092 User manual

Vista

Vista Architectural 1092 User manual

Vista 7223 Landscape Series User manual

Vista

Vista 7223 Landscape Series User manual

Vista Landscape Series User manual

Vista

Vista Landscape Series User manual

Vista 5104 User manual

Vista

Vista 5104 User manual

Vista 2165 User manual

Vista

Vista 2165 User manual

Vista 12V Series User manual

Vista

Vista 12V Series User manual

Vista 9222 Landscape Series User manual

Vista

Vista 9222 Landscape Series User manual

Vista Architectural Series User manual

Vista

Vista Architectural Series User manual

Vista Landscape Series User manual

Vista

Vista Landscape Series User manual

Vista 1093 User manual

Vista

Vista 1093 User manual

Vista 1455 User manual

Vista

Vista 1455 User manual

Vista 7216 Landscape Series User manual

Vista

Vista 7216 Landscape Series User manual

Vista 12V Series User manual

Vista

Vista 12V Series User manual

Vista 5237 User manual

Vista

Vista 5237 User manual

Vista 12V Series User manual

Vista

Vista 12V Series User manual

Vista 12V Series User manual

Vista

Vista 12V Series User manual

Vista 5250 User manual

Vista

Vista 5250 User manual

Vista Landscape Series User manual

Vista

Vista Landscape Series User manual

Vista 2125 User manual

Vista

Vista 2125 User manual

Vista 9224 User manual

Vista

Vista 9224 User manual

Vista 5203 Series User manual

Vista

Vista 5203 Series User manual

Vista 2500 User manual

Vista

Vista 2500 User manual

Vista 4017 User manual

Vista

Vista 4017 User manual

Popular Outdoor Light manuals by other brands

Atlantic SOLW2 product manual

Atlantic

Atlantic SOLW2 product manual

Vaxcel T0103 Assembly and installation instructions

Vaxcel

Vaxcel T0103 Assembly and installation instructions

LIGMAN MACARON 5 - MC-10013 installation manual

LIGMAN

LIGMAN MACARON 5 - MC-10013 installation manual

highwood Brockton Assembly guide

highwood

highwood Brockton Assembly guide

Paradise Datacom 280957 The installation, care and use

Paradise Datacom

Paradise Datacom 280957 The installation, care and use

Nualight N18497 manual

Nualight

Nualight N18497 manual

Safavieh RAINE PLT4015A quick start guide

Safavieh

Safavieh RAINE PLT4015A quick start guide

GTV STELLA Assembly instruction

GTV

GTV STELLA Assembly instruction

Vaxcel T0350 Assembly and installation instructions

Vaxcel

Vaxcel T0350 Assembly and installation instructions

GE FCB-XM-3D-XS-MS0013-29V instructions

GE

GE FCB-XM-3D-XS-MS0013-29V instructions

Sternberg Lighting LUNARIA LU300 installation instructions

Sternberg Lighting

Sternberg Lighting LUNARIA LU300 installation instructions

AM.PM Zoticus GJN661 Assembly instructions

AM.PM

AM.PM Zoticus GJN661 Assembly instructions

JONATHAN Y JYL5017A quick start guide

JONATHAN Y

JONATHAN Y JYL5017A quick start guide

V-TAC VT-1146 instruction manual

V-TAC

V-TAC VT-1146 instruction manual

Inspire Mei PL-0074KD-LP1 instruction manual

Inspire

Inspire Mei PL-0074KD-LP1 instruction manual

Lumena Charleston Eyelite instructions

Lumena

Lumena Charleston Eyelite instructions

Signature Hardware BESSEMER installation instructions

Signature Hardware

Signature Hardware BESSEMER installation instructions

Winsome house WHSL546 instruction manual

Winsome house

Winsome house WHSL546 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.