FOR USE ONLY WITH LOW VOLTAGE LANDSCAPE POWER UNITS THAT DO NOT EXCEED 25 AMPS, 15 VOLT MAXIMUM.
WARNING: Luminaires must be installed in accordance with the National Electrical Code (NEC) and local codes. Failure to do so will void the warranty and may
result in serious injury and/or damage to the luminaire.
SAFETY WARNING: Luminaire can become very hot depending on lamp wattage used. Lens and metal around lamp can become hot enough to blister hands.
Particular care should be taken not to locate luminaires where small children can reach them if high wattage lamps are used.
LUMINAIRES ARE NOT TO BE INSTALLED WITHIN 10 FT. (3.05M) OF A POOL OR SPA. SECONDARY CABLE IS NOT TO BE BURIED MORE THAN 6”.
WHEN USING MULTIPLE LUMINAIRES, LOAD IS NOT TO EXCEED THE TOTAL WATTS OF TRANSFORMER RATING. DO NOT USE EXTENSION CORDS
ON POWER UNITS.
NOTE: Always use UL recognized wire connectors for connections.
LUMINAIRE IS UL LISTED FOR ABOVE GROUND INSTALLATION ONLY.
1625 Surveyor Avenue • Simi Valley, CA 93063 • (805) 527-0987 • (800) 766-VISTA (8478)
FAX: (888) 670-VISTA (8478) • [email protected] • www.vistapro.com
Vista Professional Outdoor Lighting reserves the right to modify the design and/or construction of the fixture shown without further notification.
Shade
Ground Stake
Main Supply Cable
Silicone Filled
Safety Connectors
36” Pigtail
Stem
Path & Spread Lights
Landscape Series
7223
INSTALLATION INSTRUCTIONS - For T3-LED & T3-Halogen
WARNING - TO REDUCE THE RISK OF FIRE, OR INJURY TO PERSONS:
1. Turn off/unplug and allow to cool before replacing lamp.
2. Lamps get hot! Contact only switch/plug when turning on.
3. Do not touch hot lens, guard or enclosure.
4. Keep lamp away from material that may burn.
6. Do not operate luminaire fitting with a missing or damaged cover.
IMPORTANT SAFETY INSTRUCTIONS - THE LIGHTED LAMP IS HOT!
SAVE THESE INSTRUCTIONS (Leave with property owner/manager)
See Reverse for Fixtures with
Integrated LED Module
LUMINAIRE MOUNTING:
1. To prevent electrical shock, disconnect transformer from electrical supply
before installation or service.
2. Run wire pigtail from luminaire through mounting hole in top of ground
stake.
3. Thread luminaire into threaded hole in ground stake.
4. Place stake in desired position and insert into ground until ange of stake is
ush to grade.
5. Strip two leads from luminaire pigtail. Using two silicone filled safety
connectors (provided), connect leads from luminaire to main supply cable
leads.
NOTE: Luminaires are supplied with 36” of 18-2 cable pigtail for secure
connection to main supply cable. Wire is to be protected by routing in close
proximity to luminaire. Wiring should be buried a maximum depth of 6 inches
(15.2 cm) in order to connect to main supply cable.
6. Provide power to luminaire and check for proper operation.
NOTE: All luminaires orientation must be so that every part of the lampholder
and the lamp are greater than 2” from the ground plane.
LAMP INSTALLATION/REPLACEMENT:
CAUTION: Do not exceed maximum wattage marked on luminaire label.
1. To prevent electrical shock, disconnect transformer from electrical supply
before service.
2. Loosen lock fastener.
3. Remove shade.
4. Replace lamp with correct wattage and type marked on xture label.
NOTE: DO NOT touch lamp with bare hands. Use soft cloth to handle lamp.
5. Re-install shade.
6. Turn lock fastener to lock position.
NOTE: Halogen lamps must be protected from moisture and dust at all times.
Always re-install shade and lens when moved.
TO CLOCK PRESS DOWN &
QUARTER TURN CLOCKWISE
TO OPEN PRESS DOWN &
QUARTER TURN COUNTER CLOCKWISE
1625 Surveyor Avenue • Simi Valley, CA 93063 • (805) 527-0987 • (800) 766-VISTA (8478)
FAX: (888) 670-VISTA (8478) • [email protected] • www.vistapro.com
Vista Professional Outdoor Lighting reserves the right to modify the design and/or construction of the fixture shown without further notification.
FIXTURE TOP
LOCKING RING
MALE CONNECTOR
FIXTURE BASE
FIELD REPLACEABLE
LED ENGINE
FEMALE CONNECTOR
SPT-1 CABLE
LOCKING PIN SHOWN IN UNLOCKED POSITION
.
ROTATE 90° CLOCKWISE TO LOCK.
PRISMATIC HIGH-IMPACT
POLYCARBONATE LENS
The operating voltage range for this LED luminaire is 6 - 15 volt AC. The Vista electronic driver ensures the LED operates at the intended lumen output while
receiving voltage as low as 6 volts, and as high as 15 VAC, resulting in a balanced lumen output from the rst xture to the last. Eliminating the dimness issues
often attributed to voltage drop.
Note: Operating voltage range for LED luminaries will vary depending on model, style and total number of LEDs. To help determine the operating
voltage range for each Vista luminaire, always consult factory’s specification sheet and/or installation instructions before installation.
7223 (08/14)
Shade
Ground Stake
Main Supply Cable
Silicone Filled
Safety Connectors
36” Pigtail
Stem
Path & Spread Lights
Landscape Series
7223
FOR USE ONLY WITH LOW VOLTAGE LANDSCAPE POWER UNITS THAT DO NOT EXCEED 25 AMPS, 15 VOLT MAXIMUM.
WARNING: Luminaires must be installed in accordance with the National Electrical Code (NEC) and local codes. Failure to do so will void the warranty and may
result in serious injury and/or damage to the luminaire.
SAFETY WARNING: Luminaire can become very hot depending on lamp wattage used. Lens and metal around lamp can become hot enough to blister hands.
Particular care should be taken not to locate luminaires where small children can reach them if high wattage lamps are used.
LUMINAIRES ARE NOT TO BE INSTALLED WITHIN 10 FT. (3.05M) OF A POOL OR SPA. SECONDARY CABLE IS NOT TO BE BURIED MORE THAN 6”.
WHEN USING MULTIPLE LUMINAIRES, LOAD IS NOT TO EXCEED THE TOTAL WATTS OF TRANSFORMER RATING. DO NOT USE EXTENSION CORDS
ON POWER UNITS.
NOTE: Always use UL recognized wire connectors for connections.
LUMINAIRE IS UL LISTED FOR ABOVE GROUND INSTALLATION ONLY.
See Reverse for Fixtures with
T3-LED or T3-Halogen
INSTALLATION INSTRUCTIONS - For Integrated LED Module
LED ENGINE INSTALLATION/REPLACEMENT:
1. To prevent electrical shock, disconnect transformer from electrical supply
before service.
2. Disengage spring loaded locking pins.
3. Remove shade and lens assembly to expose LED engine.
4. Remove stainless steel locking/expansion ring.
5. Pull up field replaceable LED engine assembly.
6. Disconnect connector assembly.
7. Connect new eld replaceable LED engine to connector assembly.
8. Reinstall LED engine and secure with stainless steel locking/expansion ring.
9. Reinstall shade assembly and secure spring loaded locking pins.
LUMINAIRE MOUNTING:
1. To prevent electrical shock, disconnect transformer from electrical supply
before installation or service.
2. Run wire pigtail from luminaire through mounting hole in top of ground
stake.
3. Thread luminaire into threaded hole in ground stake.
4. Place stake in desired position and insert into ground until ange of stake is
ush to grade.
5. Strip two leads from luminaire pigtail. Using two silicone filled safety
connectors (provided), connect leads from luminaire to main supply cable
leads.
NOTE: Luminaires are supplied with 36” of 18-2 cable pigtail for secure
connection to main supply cable. Wire is to be protected by routing in close
proximity to luminaire. Wiring should be buried a maximum depth of 6 inches
(15.2 cm) in order to connect to main supply cable.
6. Provide power to luminaire and check for proper operation.
NOTE: All luminaires orientation must be so that every part of the lampholder
and the lamp are greater than 2” from the ground plane.

Other Vista Outdoor Light manuals

Vista 12V Series User manual

Vista

Vista 12V Series User manual

Vista 2130 Series User manual

Vista

Vista 2130 Series User manual

Vista 4243 User manual

Vista

Vista 4243 User manual

Vista PDK-75-5047 User manual

Vista

Vista PDK-75-5047 User manual

Vista 2166 Series User manual

Vista

Vista 2166 Series User manual

Vista 9224 User manual

Vista

Vista 9224 User manual

Vista 1093 User manual

Vista

Vista 1093 User manual

Vista 6223 Landscape Series User manual

Vista

Vista 6223 Landscape Series User manual

Vista 5237 User manual

Vista

Vista 5237 User manual

Vista Landscape Series User manual

Vista

Vista Landscape Series User manual

Vista 6216 Landscape Series User manual

Vista

Vista 6216 Landscape Series User manual

Vista 4250 User manual

Vista

Vista 4250 User manual

Vista 2165 User manual

Vista

Vista 2165 User manual

Vista 1039 User manual

Vista

Vista 1039 User manual

Vista Landscape Series User manual

Vista

Vista Landscape Series User manual

Vista 2161 Series User manual

Vista

Vista 2161 Series User manual

Vista 12V Series User manual

Vista

Vista 12V Series User manual

Vista 1447 User manual

Vista

Vista 1447 User manual

Vista T3-LED User manual

Vista

Vista T3-LED User manual

Vista 9216 Landscape Series User manual

Vista

Vista 9216 Landscape Series User manual

Vista 5104 User manual

Vista

Vista 5104 User manual

Vista 6219 Landscape Series User manual

Vista

Vista 6219 Landscape Series User manual

Vista Landscape Series User manual

Vista

Vista Landscape Series User manual

Vista 1455 User manual

Vista

Vista 1455 User manual

Popular Outdoor Light manuals by other brands

Promate Snorky user guide

Promate

Promate Snorky user guide

Xmart HL-STEP-06 user manual

Xmart

Xmart HL-STEP-06 user manual

LIGMAN LH-10573 installation manual

LIGMAN

LIGMAN LH-10573 installation manual

Saxby Lighting 1818PIR Instruction leaflet

Saxby Lighting

Saxby Lighting 1818PIR Instruction leaflet

CLAS OE 0396 manual

CLAS

CLAS OE 0396 manual

Santa & Cole Urbidermis SKYLINE Assembly instructions

Santa & Cole Urbidermis

Santa & Cole Urbidermis SKYLINE Assembly instructions

Steren LAM-850 instruction manual

Steren

Steren LAM-850 instruction manual

Alice's Garden VASO 65 manual

Alice's Garden

Alice's Garden VASO 65 manual

MaxLite ML4LE109S BK2 Series operating instructions

MaxLite

MaxLite ML4LE109S BK2 Series operating instructions

marset Lab 35/60 B Assembly instructions

marset

marset Lab 35/60 B Assembly instructions

Original BTC Davey Lighting 7672 Safety & installation instructions

Original BTC

Original BTC Davey Lighting 7672 Safety & installation instructions

Schrack TRUST WALL instruction manual

Schrack

Schrack TRUST WALL instruction manual

Acuity Brands Holophane DSX1 installation instructions

Acuity Brands

Acuity Brands Holophane DSX1 installation instructions

BGS technic 9767 instruction manual

BGS technic

BGS technic 9767 instruction manual

Gainsborough H738 Assembly instructions/Instructions for use

Gainsborough

Gainsborough H738 Assembly instructions/Instructions for use

Quoizel WVR1612EK installation guide

Quoizel

Quoizel WVR1612EK installation guide

Home Decorators Collection HB7251-292 Use and care guide

Home Decorators Collection

Home Decorators Collection HB7251-292 Use and care guide

Artika C7 AMP101B-C8SS instruction manual

Artika

Artika C7 AMP101B-C8SS instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.