manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. VOLKTEK
  6. •
  7. Media Converter
  8. •
  9. VOLKTEK NGF-762E User manual

VOLKTEK NGF-762E User manual

Other VOLKTEK Media Converter manuals

VOLKTEK NXF-742 User manual

VOLKTEK

VOLKTEK NXF-742 User manual

VOLKTEK IMC-561P User manual

VOLKTEK

VOLKTEK IMC-561P User manual

VOLKTEK NMF-747 User manual

VOLKTEK

VOLKTEK NMF-747 User manual

VOLKTEK IMC-563 User manual

VOLKTEK

VOLKTEK IMC-563 User manual

VOLKTEK NWT-707 User manual

VOLKTEK

VOLKTEK NWT-707 User manual

VOLKTEK IMC-563P User manual

VOLKTEK

VOLKTEK IMC-563P User manual

VOLKTEK IRF-633 User manual

VOLKTEK

VOLKTEK IRF-633 User manual

VOLKTEK IRF-629 User manual

VOLKTEK

VOLKTEK IRF-629 User manual

Popular Media Converter manuals by other brands

TR-Electronic CMS582M-4096/4096 IOL DMS 14H7 KRF Assembly instructions

TR-Electronic

TR-Electronic CMS582M-4096/4096 IOL DMS 14H7 KRF Assembly instructions

Korenix JetCon 2301S user manual

Korenix

Korenix JetCon 2301S user manual

StarTech.com ET91000LCOAM manual

StarTech.com

StarTech.com ET91000LCOAM manual

Alesis AI-3 Reference manual

Alesis

Alesis AI-3 Reference manual

Caton Vpro 5100 user guide

Caton

Caton Vpro 5100 user guide

Cypress CSC-5500 Operation manual

Cypress

Cypress CSC-5500 Operation manual

H&B TX-100 Installation and instruction manual

H&B

H&B TX-100 Installation and instruction manual

Bolin Technology D Series user manual

Bolin Technology

Bolin Technology D Series user manual

IFM Electronic Efector 400 RN30 Series Device manual

IFM Electronic

IFM Electronic Efector 400 RN30 Series Device manual

GRASS VALLEY KUDOSPRO ULC2000 user manual

GRASS VALLEY

GRASS VALLEY KUDOSPRO ULC2000 user manual

Linear Technology DC1523A Demo Manual

Linear Technology

Linear Technology DC1523A Demo Manual

Lika ROTAPULS I28 Series quick start guide

Lika

Lika ROTAPULS I28 Series quick start guide

Weidmuller IE-MC-VL Series Hardware installation guide

Weidmuller

Weidmuller IE-MC-VL Series Hardware installation guide

Optical Systems Design OSD2139 Series Operator's manual

Optical Systems Design

Optical Systems Design OSD2139 Series Operator's manual

Tema Telecomunicazioni AD615/S product manual

Tema Telecomunicazioni

Tema Telecomunicazioni AD615/S product manual

KTI Networks KGC-352 Series installation guide

KTI Networks

KTI Networks KGC-352 Series installation guide

Gira 0588 Series operating instructions

Gira

Gira 0588 Series operating instructions

Lika SFA-5000-FD user guide

Lika

Lika SFA-5000-FD user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

-1- -2- -3-
Quick Installation Guide
NGF-762E
1. Overview
2. Package Checklist
4. DIP Switches
Front Panel View
Fiber Port
SFP Type Media Converter
LED Indicators Copper Port
Fiber Port LED Indicators Copper Port
Rear Panel View with DIP Switches
Converter with 1x9 SC and RJ45 connectors
Converter with SFP and RJ45 connectors
The NGF-762E Converter is used to connect devices
with 10/100/1000Base-T cable to ber-based Ethernet.
The NGF-762E is enhanced with Link Fault Signaling,
Loop-back Testing and SFP dual speed setting.
5. Location
The NGF-762E can be placed on a desktop or horizontal
surface, it can be wall-mounted.
Step1: The wall-mount direction can be straight or
horizontal.
Step2: Please this device by using mounting holes on
the wall at the appropriate place.
3. Hardware Installation Procedure
STEP 1: Remove from packaging and connect the 12V
DC adapter to the power input on rear panel.
STEP 2: Connect the Ethernet (RJ-45) port to the
networking device. See the LNK/ACT LED to
conrm if the connection is established.
STEP 3: Connect the ber cable to the ber port.
STEP 4: See DIP switches on rear panel to enable/
disable the required features per application
Before installing the NGF-762E, verify that the package
contains the following items:
1 x NGF-762E Converter
Power adapter (Check for area type)
Quick Installation Guide
10/100/1000100/1000
Fiber RJ45
ALM
1000
LNK/
ACT
1000
TX 10/100/1000
Fiber RJ45
ALM
LNK/ACT
1000
RX
1
2
3
4
5
6
7
LFS
LLB
RLB
100FX
RSV
RSV
RSV
DIP Key
12VDC
1 2 3 4 5 6 7
PWR
ON
OFF
1x9 Type Media Converter
1
2
3
4
5
6
7
LFS
LLB
RLB
RSV
RSV
RSV
RSV
DIP Key
12VDC
1 2 3 4 5 6 7
PWR
ON
OFF
1. LFS ON : Link fault signal function is enabled
OFF: Link fault signal function is disabled. (Default)
2. LLB ON : Local loopback function is enabled
OFF: Local loopback function is disabled. (Default)
3.RLB ON : Remote loopback function is enabled
OFF: Remote loopback function is disabled. (Default)
4.100FX
This is function is only for SFP type media converter
ON : When install the 100FX SFP transceiver,
please set this DIP to ON.
OFF: When install the 1000Base-X SFP transceiver,
please set this DIP to OFF. (Default)
5~7 RSV The DIP means Reserve. The default is in OFF position.
Moun�ng holes for
device
Moun�ng holes drawing of device
50mm
50mm
1.5mm~3mm
Screw installa�on Distance
-4- -5- -6-
6400-000123
6. Cabling RJ45
Connect Ethernet/RJ45 cable into Ethernet port of media
converter and other end to attached networking device.
• Copper of the media converter supports Fast Ethernet
as well as Gigabit Ethernet (10/100/1000Base-T RJ45
Port)
• The RJ45 port on the media converter supports auto
negotiation and auto MDI/MDI-X to eliminate the need
for crossover cabling.
Note: Category 5e cable or above should be used.
7. Link Fault Signaling (LFS)
The LFS LED will immediately light to indicate when a
cable has been severed or when some other cause of
disruption in service has occurred. The LFS function
monitors both copper and ber segment giving a total
connection status report.
DIP Switch 1: Set LFS to ON for normal operational use;
OFF when installing cables or when
testing the network connection.
7. Loop back Test
8. LED Indicators
This Converter features DIP switches to activate both
local and remote loopback diagnostic test functions. Use
local loop back (LLB) to check if the copper segment is
connected properly, and use remote loop back (RLB) to
check if the ber segment is connected properly.
Note: When enabling loopback testing in one side, another’s
trac will be blocked until the loopback is disabled.
Limited Warranty
VOLKTEK Corporation warrants this product against defect in materials
and workmanship for a period of TWO (2) YEARS to the original
purchaser.
If you discover a defect, VOLKTEK will, at its sole option, repair or
replace the product at no additional charge, provided that you contact
VOLKTEK technical support to obtain a Return Merchandise Authoriza-
tion Number (RMA) and instruction on how and where repairs can be
made. This warranty does not apply if the product has been damaged
by accident, abuse, misuse, misapplication, neglect, re, water,
lightning or other acts of nature, failure to follow supplied instructions,
installation or removal, have been repaired or have undergone
attempted repair by unauthorized personnel without written consent
from VOLKTEK, modied, defaced, or has its serial numbers removed.
VOLKTEK reserves the right to use remanufactured, refurbished, or
used parts and components in making warranty repairs.
All expressed or implied warranties for this product, including the
implied warranties of merchantability and tness for a particular
purpose are limited in duration to the warranty period. No warranties
expressed or implied will applied after this period. VOLKTEK shall not
be liable for lost prots, damage to other property caused by any
defects of this product, or damages based upon inconvenience, loss of
product use, loss of time, commercial use, incidental and/or
consequential damages for the breach of any expressed or implied
warranty, including damages to property, and to the extent permitted
by law, damages for personal injury, even if VOLKTEK has been advised
of the responsibilities of such damages.
If you have any further questions, please contact Customer Support:
Address of the manufacturer.
VOLKTEK CORPORATION
4F, 192 Liancheng Rd, Zhonghe, New Taipei 23553, Taiwan
Email: [email protected]
Tel: +886-2-8242-1000
Fax: +886-2-8242-3333
Straight direction installation
Moun�ng direc�on
with screw
Horizontal direction installation
Moun�ng direc�on
with screw
RJ45
Fiber
LLB
RLB
Illuminated
O
PWR
(Green)
Power On by 12VDC power input
Power fails or is not available
Illuminated
O
ALM
(Red)
LFS enabled and link fault happened
LFS disable or no link fault happened
LNK/ACT
RJ45
1000 Illuminated
O
links speed at 1000Mbps
Link speed at 10/100Mbps or link failed
Illuminated
Blinking
O
Copper port link-up
Data is transmitting / receiving
Link failed
LNK/ACT
Fiber
1000 Illuminated
O
links speed at 1000Mbps
Link speed at 100Mbps or link failed
Illuminated
Blinking
O
Fiber port link-up
Data is transmitting / receiving
Link failed
Operating Temperature
0˚C~50˚C
Storage Temperature
-20˚C~70˚C
Altitude
Up to 2000m
Ambient relative humidity
10 to 95% (non-condensing)
9. Environmental limits
!ATTENTION:
This device complies with Part 15 of the FCC rules.
Operation is subject to the following conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received
including interference that may cause undesired operation.
!ATTENTION:
If the equipment is used in a manner not specied by the
VOLKTEK, the protection provided by the equipment may
be impaired.