-4- -5- -6-
6400-000108
7. NWay DIP Switch Setting
Use the NWay DIP switch to activate NWay operations.
Factory NWay DIP switch default is set to ON position.
Check that the networking device to be connected to
the Converter has NWay support.
If YES: Check that the NWay DIP switch is set to the
ON position. The Converter will automatically set the
optimum speed and duplex mode on the copper
segment. Users can skip the settings for DIP switches 2
and 3, when NWay is activated.
If NO: Set the NWay DIP switch to the OFF position.
Then Use DIP switch 2 to manually select between half
(HD) and full duplex (FD) modes. Use DIP switch 3 to
manually select between 10Mbps or 100Mbps speeds.
Set NWay switch to OFF position when connecting to
an auto-sensing device that only supports 10/100Mbps
detection. Some early switch models only support auto-
sensing of speed, and NOT auto detection of speed and
duplex mode (auto-negotiation).
Setting the duplex mode is feasible while the media
converter is “on-line”.
8. Link Fault Signaling (LFS)
The LFS LED will immediately light to indicate when a
cable has been severed or when some other cause of
disruption in service has occurred. The LFS function
monitors both copper and ber segments giving a total
connection status report.
Set LFS to ON for normal operational use. OFF
when installing cables or when testing the network
connection.
9. Loop-back Test
This Converter features DIP switches to activate both
local and remote loopback diagnostic test functions.
Use local loop back to check if the copper segment is
connected properly, and use remote loop back to check
if the ber segment is connected properly.
Dip Switch 6 ON: enables remote loop-back function
OFF: disables remote loop-back function
Conduct either the local or remote test, not both at the
same time.
10. Environmental limits
Operating Temperature 0~50℃
Operating Humidity 10~95%RH (non condensing)
11. LED Indicators
This Converter has LED indicators located at the front
of the device. These have been designed to give easy
at-a-glance network status. Please see below for an
interpretation of their functions:
Unit LEDs
LED Condition Status
PWR On (Green) Converter is
receiving power
O Power o or failure
LFS On (Red)
Disruption of
connection in
copper/ber
segment
100
On (Green) Port operating at
100Mbps
O Port operating at
10Mbps
LNK/ACT
On (Green)
Illuminated when
connectors are
attached
Blinking (Green) Trac passing
through port
O No valid link
established
FDX/COL
On (Yellow) Port is operating at
full duplex
Blinking (Yellow) Indicates collision
O Port is operating at
half duplex
If you have any further questions, please contact
Customer Support:
www.volktek.com
Ph: +886-2-8242-1000 / Fax: +886-2-8242-3333