9
Avoid excessive pressure when using cleaning instruments. This can lead to
scratches or cracks in the film.
Check the condition of the film regularly. If damage occurs (e.g. cracks,
holes, deformations), the film must be replaced immediately.
If the printer is used to produce medical products it is necessary to use separate
PowerVats for each printing material. Otherwise, cross-contamination cannot be
prevented. Between the PowerVat top part, the rubber seal and the film, a small
amount of 3D printing resin can accumulate. When changing the material, it is
therefore recommended to disassemble the PowerVat upper part so material
residues can be completely removed. Make sure to follow the instructions of the
3D printing material manufacturer, especially with regard to backfilling and, if
necessary, sieving the material.
Utilize the exposure area of the PowerVat evenly so that the entire surface is used
uniformly throughout its lifetime. Localized exposure leads to higher local wear
and thus reduces the overall life of the film.
For a proper cleaning of the PowerVat, a clean working environment must be
ensured.
Please use only the following tools or materials:
soft cleaning tissues or paper towels
microfiber cloth
silicone spatula (solvent resistant - soft)
cleaning pad (solvent resistant)
isopropanol (purity at least 95%)
blunt spatula for cleaning corners and removing material residues
Use only oil and grease-free compressed air. Make sure that there are no persons
in the airflow when using compressed air.