User'sManual
SafetyPips withrelay output
(7100.181.K)
ContinuousWrist Strap Monitor
withrelayoutput
Wolfgang WarmbierGmbH & Co. KG
Systeme gegenElektrostatik
UntereGießwiesen21
78247 Hilzingen, Germany
www.warmbier.com
SafetyPipsK- User'smanual
Part No.:7100.181.K
_
Seite 2von 4V2020-12
nIntroduction
The SafetyPips isacontinuous wriststrap monitor. The person wearingthe wristband is
grounded andcheckedpermanentlybyameasurementofresistanceand body capacity.
When measuring the inputresistance ofthe instrumenttoground,please use avoltage above
15 Volt because ofthe 12Volt protection zener diodes fittedintheinstrument.
nInstallation
1.Fixthe SafetyPips attheworkplace wherethe twosignalLED'scan beseen.
2.Open the lidforthescrewclamp.
3.Connectterminal2 toasuitablegrounding point.
Atdeliverythereisadirectconnectionfromterminal1(B)to2 and noconductive fixtures
orthe grounding aremonitored.
Ifgroundedconductivefixturesshall bemonitored,connectthemtoterminal1(B)and
removethedirect connection betweenterminal1(B) and2 .
Tomonitorthe groundingoftheunit(instead ofconductive fixtures)connectan additional
earthwiretoterminal1(B)and toasecondsuitablegrounding point.andremove the direct
connection between terminal1(B) and2 .
4.Connectthe powersupplytoterminal3and 4.
5.External monitoring logiccan beconnected tothesignalcontactterminal5and 6.
6.Connectthe powersupplytothemains voltage.
nOperation
Putonthewriststrapandconnectthe coil cordsnap totheSafetyPipsfrontconnector.The
instrumentispermanentlyswitchedon.
The SafetyPips monitorstheconnecting cordsand the contactbetween the wriststrap and
the humanskinby testingpermanentlyifthe resistance and the bodycapacityofthe person
wearing thewriststrap iswithinthespecified range.
Screw clamp
compartment
LEDindicator
Wrist strap connector
with 10mm snap
Illustration:
Optionalbracket forfixing the instrument
undera work bench (Part no.: 7100.181.H)
SafetyPipsK
Constant
Wrist StrapMonitor
Hi-Fail
Lo-Fail
OK
SafetyPipsK- User'smanual
Part No.:7100.181.K
_
Seite 3von 4V2020-12
nSignalsandpossibleerrorconditions
Green
LEDflashes
Resistance andcapacityareinthe ratedrange
RedLEDflashes
Reason:
The measured resistanceistoohigh
Measures:
Check ifthe wriststrap isfixed tighttotheskin
Check if grounding wireorthe coil cordarebroken
RedLEDispermanenton
Reason
1
:
The measured resistanceistoolow
Measures1:
Check ifthe coil cordcontains asafetyresistor
Check for aninsulation failure
or atobigcapacitytoconductive tablemats
Reason 2:
Directconnectionbetween terminal1and2ismissing,connectionto
conductive fixtures isbroken orone ofthe earthwires isbroken
Measures
2
:
Check connections toterminal1and2
nCalibration
ACalibration Unit isavailabletocheck the Safetypips
correctfunction and values (Partno.: 7100.181.C)
nModelsand accessories
Availablemodels:
Part No.
Description
7100.181 SafetyPips with10mm snap, grounding cordwith4mmring
terminal
7100.181.K SafetyPips withrelay output, 230Vpowersupply,
without audiblealarm
Availableaccessories:
Part No.
Description
7100.181.C Calibration Unit for SafetyPips
7100.181.H
Bracketfor SafetyPips
7100.181.103 Power supply230VAC/9VDC for SafetyPips with
Pa
rt
-
N
o
.:
7100.181
SafetyPipsK- User'smanual
Part No.:7100.181.K
_
Seite 4von 4V2020-12
nTechnicaldata
Power supply: Power supply230V/50Hz
Connectors: 10 mmsnap forcoil cords
Contactratings: Max.voltage: 60V
Max.current:0.2A
Max.power: 6VA
Switch on timeofsignal contact: ca. 1s
Switch offtimeofsignal contact: ca. 5s
Test voltage (open circuit) DC < 0,01 Volt
AC < 4,00 Volt
Test current at1,0MWload: DC < 0,01 µA
AC < 1,00 µA
Case: ABS, black,dissipative (except thenameplate)
Operating conditions: Temperaturerange:+ 10°C to+ 40°C
Relative humidity: 20%to80 %
Dimensions: 125 x60x26 mm
Weight: app. 85g
nInputimpedances
Pass (greenLEDflashing)
Lower rated value: 1MOhm-10 %
Upper rated value: 100 pF+ 2MOhm+10 %
Faultcondition(redLEDand beep)
Lower rated value (permanentred): 400 kOhm
Upper rated value (flashing red): 5MOhm
nInputimpedances forcontrolinput B
Pass (greenLEDflashing)
Upper rated value: 100 Ohm
nWastedisposal
According toWEEEDirective 2012/19/EU the device ismarkedwiththissymbol.
Thisdevice mustthereforenot bedisposed of withthehouseholdwaste.

Other Warmbier Measuring Instrument manuals

Warmbier SRM 110 User manual

Warmbier

Warmbier SRM 110 User manual

Warmbier SRM 110 User manual

Warmbier

Warmbier SRM 110 User manual

Warmbier 7100.181 User manual

Warmbier

Warmbier 7100.181 User manual

Warmbier SRM 200 User manual

Warmbier

Warmbier SRM 200 User manual

Popular Measuring Instrument manuals by other brands

Black Box FOPM-210 quick start guide

Black Box

Black Box FOPM-210 quick start guide

AquaLab PRE quick start guide

AquaLab

AquaLab PRE quick start guide

Lightobject Ranger3 Operation manual

Lightobject

Lightobject Ranger3 Operation manual

Zeroplus I2C-SPI user manual

Zeroplus

Zeroplus I2C-SPI user manual

Co2meter AZ 77535 Operation manual

Co2meter

Co2meter AZ 77535 Operation manual

Blackline Safety G7 BRIDGE Technical  user's manual

Blackline Safety

Blackline Safety G7 BRIDGE Technical user's manual

MPFiltri LPA2 user guide

MPFiltri

MPFiltri LPA2 user guide

Promax HD Ranger + user manual

Promax

Promax HD Ranger + user manual

iSens i-SmartCare 10 Operator's manual

iSens

iSens i-SmartCare 10 Operator's manual

Trans-Tek GBF-1717-W user manual

Trans-Tek

Trans-Tek GBF-1717-W user manual

Prostat PRF-912B user manual

Prostat

Prostat PRF-912B user manual

Kyoritsu Electrical Instruments Works, Ltd. KEW LOGGER Series instruction manual

Kyoritsu Electrical Instruments Works, Ltd.

Kyoritsu Electrical Instruments Works, Ltd. KEW LOGGER Series instruction manual

MYPV Digital Meter P1 interface quick start guide

MYPV

MYPV Digital Meter P1 interface quick start guide

d & b audiotechnik ArraySight manual

d & b audiotechnik

d & b audiotechnik ArraySight manual

Aqualytic AL100 instruction manual

Aqualytic

Aqualytic AL100 instruction manual

Avtech Room Alert 32E user guide

Avtech

Avtech Room Alert 32E user guide

Axio MET AX-C800 Operation manual

Axio MET

Axio MET AX-C800 Operation manual

red lion PAX2D user manual

red lion

red lion PAX2D user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.