Water Body Glove BG-12000 User manual

W-851 Rev 08/08
Installation and Operating Instructions For:
BG-12000, BG-3000, and BG-1000
Installer:
Please leave manual with homeowner.
Homeowner: Please retain for operation and future maintenance instructions.
Internationally Distributed by Water, Inc.
Carson, CA 90746
1-800-322-WATER (9283)
http://bodyglove.waterinc.com
W-851 BG Combined MANUAL RELEASE COPY.pdf

SAFETY INFORMATION
IMPORTANT NOTES
Please read and follow all safety information contained in these instructions prior to installation
and use of the Body Glove BG-12000, BG-3000 and BG-1000 Systems. Retain these instructions for
future reference.
Intended use:
The BG-12000, BG-3000, and BG-1000 Systems are intended for use in filtering potable water in homes
and have not been evaluated for other uses. The system is typically installed under a sink, and should be
installed by a qualified installer according to these installation instructions.
EXPLANATION OF SIGNAL WORD CONSEQUENCES
CAUTION
WARNING Indicates a potentially hazardous situation, which, if not avoided, could
result in death or serious injury and/or property damage.
WARNING
To reduce the risk associated with ingestion of contaminants due to use with water that is microbiologically
unsafe or of unknown quality:
• Donotusewithwaterthatismicrobiologicallyunsafeorofunknownqualitywithoutadequate
disinfectionbeforeorafterthesystem.
To reduce the risk associated with hazardous voltage due to an installer drilling through existing electric
wiring or water pipes in the area of installation:
• Donotinstallnearelectricwiringorpipingwhichmaybeinthepathofadrillingtoolwhenselectingthe
positiontomountthelterbracket.
•Failuretofollowinstructionswillvoidwarranty.
•Installwiththeinletandoutletportsaslabeled.Makesurenottoreverseconnections.
To reduce the risk associated with property damage due to water leakage:
• Read Use Instructionsbeforeinstallationanduseofthissystem.
• Installationanduse MUST comply with all state and local plumbing codes.
• Protect from freezing, remove filter cartridge when ambient temperatures are expected to drop below 40°F
(4.4° C).
•Do not install on hot water supply lines.Themaximumoperatingwatertemperatureofthisltersystemis
100°F(37.8°C).
• Do not install ifwaterpressureexceeds125psi(862kPa).Ifyourwaterpressureexceeds80psi(552
kPa),youmustinstallapressurelimitingvalve.Contactaplumbingprofessionalifyouareuncertainhowto
checkyourwaterpressure.
• Do not install wherewaterhammerconditionsmayoccur.Ifwaterhammerconditionsexistyoumustinstall
awaterhammerarrester.Contactaplumbingprofessionalifyouareuncertainhowtocheckforthiscondi-
tion.
• Do not use a torch or other high temperature sources near filter system, cartridges, plastic fittings or plastic
plumbing.
• Onplasticttings,neverusepipesealantorpipedope.UsePTFEthreadtapeonly, pipe dope properties may
deteriorate plastic.
• Takecarewhenusingpliersorpipewrenchestotightenplasticttings,asdamagemayoccurif
overtightened.
• Do not install in direct sunlight or outdoors.
• Do notinstallnearwaterpipeswhichwillbeinpathofadrillingtoolwhenselectingthepositiontomount
thebracket.
• Donotusepliersorapipewrenchtotightenwheninstallingreplacementcartridge.
• Mountlterverticallyinsuchapositionastopreventitfrombeingstruckbyotheritemsusedintheareaof
installation.Forhorizontalinstallation,additionalsupportofthelterisrequired(notincluded).
• Ensurethatthelocationandfastenerswillsupporttheweightofthesystemwithwaterwheninstalled.
• Ensurealltubingandttingsaresecureandfreeofleaks.
• Donotinstallunitifcolletismissing.ContactWaterInc.ifcolletsaremissingfromanyttings.
• ThedisposableltercartridgeMUST be replaced every twelve months,attheratedcapacityorifthereisa
noticeable reduction in flow rate, whichever occurs first.
Indicates a potentially hazardous situation, which, if not avoided, may
result in property damage.
— 2 —
W-851 BG Combined MANUAL RELEASE COPY.pdf

BG-12000BG-3000BG-1000
Filter Cartridge Filter Head/Shroud
13 1/4”
15 1/2”
To use with all available cartridges, the cartridge must be
mounted with at least the amount of space indicated.
16 1/4”
4 7/16"
4 7/16"4 7/16"
3 1/4" 5 1/2" 2 1/2"
Parts and Materials Included:
• FilterCartridge
• FilterHeadAssembly
• FilterHeadShroud
• (2)QuickConnectFittings
• (1)3/8”IPSx1/4”QuickConnect
Riser Adapter
• (2)PhillipsHeadMountingScrews
• (2)MountingScrewStarWashers
• (1)QuickConnect1/4”BallValve
• 7’of1/4”PlasticTubing
• FaucetAdapter3/8”x1/4”Quick
ConnectFitting
• FilterVentTube
(ConnectedtoFilterHeadAssembly)
• WaterFilterReplacementIndicator&
Instructions
• PerformanceIndicatorDevice(PID)
[BG-12000only]
• (2)QuickConnectPIDFittings
[BG-12000only]
• PIDBatteries&Instructions
[BG-12000only]
• OwnersManual
• Pre-rinseFlushInstructionCard
• Warranty/ExtendedWarrantyProduct
Card
• FilterRecycleInstructionCard
• WarrantyServiceCard
• ProductPerformanceDataSheet(PDS)
• CaliforniaCertificationSheet
• SpecificationSheet
GETTING STARTED
Typical Installation Example
Drinking Water Faucet
(Not Included)
Riser Adapter
Ball Valve
(Optional)
Performance
Indicator Device
(PID)
[BG-12000 only]
Filter Head/Shroud
Filter Cartridge
Water Filter Replacement
Indicator Device
Faucet Adapter
Filter
Vent Tube
1/4” Plastic Tubing 1/4” Plastic
Tubing
— 3 —
Tools Required (not included):
• Drill(Cordlessrecommended)
• Adjustablewrench
• Phillipsheadscrewdriver
• Razorknifeortubecutter
Additional Parts Required (not included):
• DrinkingWaterFaucet
W-851 BG Combined MANUAL RELEASE COPY.pdf

For Use With Cold Water Only.
NOTE:Removeitemsfromunderthesink.Placecatchbasintheretocollectsmallamountsofwaterthatmayrunout
when disconnecting water supply lines.
1. Turnoffcoldwatersupplyvalve.
Install(2)quickconnectfittingsintoheadassemblyusingPTFEthreadtapeonly.
2. Removecoldsiderisertubingconnectionatanglestop.InstallQuickConnect
riseradaptertoanglestopandreconnectrisertubetothequickconnectriser
adapter.
3. Selectandmarkalocationunderthesinkthatallowsaccessforfilterchange.
Measuredimensionsoflocationforfiltertoallowforthefollowingmin/max
space:6”WX5½”DX19”H(note:ifthecartridgeistootallforthebaseof
thecabinet,aholecanbecuttoallowforthefiltertobechanged).
4. Usingfilterhead/bracketasaguide,markholelocationssothatthereis11/2”
betweenthescrews(seeFigure1),fromcenterofeachscrew.
Installscrewsandwashers,butonlyhalfway,soyoucan
easilyslipthebrackettowallbeforefirmlysettingscrews.
Wheninstalled,thebottomofthefiltershouldhavea
minimumclearanceof21/2”fromsinkcabinetfloorto
facilitatecartridgechange.
FastenFilterHeadAssemblytowallwithPhillipsheadmounting
screws supplied.
5. Cuttubingstraightwitharazorknifeortubecutter.
(SeeFigure2).
Determinelengthoftubingrequiredfromfilterhead/brackettofaucetandfromwatersupplylinetofilter
head/bracketbyholdingtubinginplaceensuringitisofappropriatelength.Donotkinktubingasthiswillimpede
waterflow.Ifnecessary,looptubingaroundtoavoiditbeingkinked.
Connect1/4”tubingfromriseradaptertoinletsideoffilterhead.(See“UsingPush-InFittings.)
Installoptionalballvalveinlinefromwatersupplytofilterheadbracket.
BG-12000Only:InstallandmountPID(required)per
instructionsinsection“OperationInstructionsForTheDigiflow8800TPerformanceIndicatorDevice(PID).
Correct Incorrect
Figure2
Collet
Backstop
“Using Push-In Fittings”
To Attach Tubing
(1) Push tubing in as far as it will go.
(2) Tubing must be inserted past o-ring and hit backstop.
Pull tube to ensure it is secured.
To Release Tubing
(3) Push in collet to release tubing.
(4) With collet held, pull tubing straight out.
INSTALLATION INSTRUCTIONS
Figure1
CAUTION
To reduce the risk associated with property damage due to water leakage:
• Ensurealltubingandttingsaresecureandfreeofleaks.
— 4 —
W-851 BG Combined MANUAL RELEASE COPY.pdf

6. Installfaucetadapterfittingtodrinkingwaterfaucet(drinking
waterfaucetnotincluded).Thisshouldbeasnugfit.Do not
overtighten.(SeeFigure3)
7. Referringtothe“UsingPush-InFittings”section,insertthe
NSFapprovedtubingintothefaucetadapterfitting,making
sure the end of tubing is firmly seated.
Holdthefilterheadassemblyawayfromthewall,pressother
endoftubingintooutletsideasindicatedbyarrowonfilter
headassembly.(seeFigure4)
8. Placefilterheadassemblyholesovermountingscrewsandpressdowntolockintoplace.Tightenthescrewsfora
securefit.
9. Insertfilterintofilterheadassemblybyaligningarrowprintedonthetopofcartridgelabelwitharrowonfilterhead.
(Note:arrowislocatedundertheshroudonthefilterheadbodyontheinletwaterside).Turnfilteronequarter
turntotherightuntilitstops.Whenfullyengaged,thetopsurfaceofthefilterwillbeflushwiththebottomofthe
filterheadassembly.
10. Turnonwaterandopenfiltersystemfaucettoflushairfromthe
system. Run water for a minimum of 4
gallons (approximately 5 minutes) to flush system of carbon
fines and release trapped air. Flush water into a bucket or
pail and reuse the water for garden or landscape watering.
While system is flushing, check for leaks. Repair any leaks
as needed before continuing.
Closefiltersystemfaucet.Thesystemisnowreadyforuse.
Systemisnowunderpressureandcanbeinspectedforleaks.
Repairanyleaksasneededbeforecontinuing.
Note: White tube from head is a filter vent tube outlet. DO NOT remove, kink or obstruct white tube.
Push In Push In
Figure4
INSTALLATION INSTRUCTIONS (CONTINUED)
— 5 —
I
nstall F
a
ucet
Ad
apter
Fi
tt
i
n
g
Typical connection shown.
Refer to installation
instructions for your
particular fixture.
Figure3
W-851 BG Combined MANUAL RELEASE COPY.pdf

FILTER CARTRIDGE REPLACEMENT INSTRUCTIONS
To maximize effectiveness and to help reduce the possibility of service related issues, the disposable,
environmentally friendly & recyclable filter cartridge must be replaced every twelve months. Water, Inc values
your choice in the highest quality water treatment. Failure to follow these instructions may void your warranty and
increase the risk of incidental water or property damage.
To reduce the risk associated with property damage due to water leakage:
• Donotusepliersorapipewrenchtotightenwheninstallingreplacementcartridge.
• ThedisposableltercartridgeMUST be replaced every twelve months,attheratedcapacityorifthereisa
noticeable reduction in flow rate, whichever occurs first.
IMPORTANTNOTE
• BG-12000ModelOnly:Changeltercartridgeat12monthsor1,000gallons,asindicatedbyDIGIFlow8800T
PID,whicheveroccursrst.
1. Placetowelunderfiltertocollectanyresidualwaterduringcartridgechange-out.
2. Graspcartridgeandturntotheleft(counterclockwise)untilcartridgecomestoacompletestop(waterautomatically
turnsoff).Watermayleakmomentarilyfromventtube.Thisisnormal.Gentlypullcartridgedownwardtoremove.
3. RemoveREDsanitaryprotectivecapfromnewcartridge.
4. Ensurethato-ringsarepresentonthecartridgeandareseatedintogrooves;moisteno-ringswithwater.DONOT
use any petroleum products to lubricate the o-rings.
5. Insertfilterintofilterheadassemblybyaligningarrowprintedontopof
cartridgelabelwitharrowonfilterheadbracket.(Note:arrowislocatedunderthe
shroudonthefilterheadbracketontheinletwaterside).Turnfiltercartridgeone
quarterturntotherightuntilitstops.Whenfullyengaged,thetopsurfaceofthe
filterwillbeflushwiththebottomofthefilterheadassembly.
6. Open faucet and run water for a minimum of 4 gallons (approximately 5
minutes) to flush system of carbon fines and release trapped air. Flush
water into a bucket or pail and reuse the water for garden or landscape
watering. While system is flushing, check for leaks. Repair any leaks as
needed before continuing.
Close filter system faucet. System is now under pressure and can be inspected for leaks. Repair any leaks
as needed before continuing. The system is now ready for use.
7. Please review section “Water Filter Replacement Indicator” for instructions on how to activate and/or test this
device.
WATER FILTER REPLACEMENT INDICATOR
ACTIVATION AND USE INSTRUCTIONS (All Models):
1. Removefilterreplacementindicatorfromplasticbag
2. Toactivate,pressandhold“START”buttonfor3seconds.LEDlightwillflash3timesandthealarmwillbeep3
timesconfirmingcountdownhasbegun.
3. Mounttheindicatorinaconvenientlocationusingtheattachedmagnetordoublesidedtapeprovided
4. ReplacefilterwhenLEDlightbeginstoflashonceeveryminuteoralarmbeepsonceeveryhour
5. Disposeoffilterreplacementindicatoraftertheoldfilterhasbeenchanged.Anewtimerwillbeincludedwiththe
replacementfilter.
TestMode:
1. Totestindicatoratanytimeduringthecountdownperiod,pressandholdthe“START”buttonfor1second.The
LEDlightwillflashonceandthealarmwillbeeponceindicatingthetimerisinactivecountdownmode.
IMPORTANTNOTE
Thisfilterreplacementindicatorisdesignedforone-timeonlyuse.
— 6 —
W-851 BG Combined MANUAL RELEASE COPY.pdf

1. Install batteries (included): Remove the battery compartment cover located on the
topoftheunitandinstalltwo(2)“AAA”batteries.Replacebatterycompartment
cover.TheLCDpanelshouldnowshow“1,000gal”.
2. Installfittings:TheDigiFlow8800Tconnectionis3/8”MNPTfemale.Fittingsto
useare3/8”MNPTmaleconnectionwhichisconnectedtothesupplyandfeed
tubes.Installbothfittingstoadistanceof1/8”(0.32cm)fromflowmonitor
housing(seefigure2totheright).
3. Operation:TheDigiFlow8800Tturnsonandshowsremainingcapacityonthe
screenwhenthereiswaterflowingthroughit.ThedisplayontheLCD
screenturnsoffin10secondsifthereisnowaterflowing.Tocheck
thestatusoftheremainingcapacityoftheinstalledcartridge,pressthe
“CHECK/RESET”button.
4. EndofCartridgeLifeAlarm:Whentheremainingcapacityoftheinstalled
cartridgereaches0gallonsasindicatedontheLCDscreen,thePIDwill
soundashort“beep-beep”alarmandthe“0”digitontheLCDscreen
blinks,signalingtimetoreplacethecartridge.
5. ResetPID:Afterthecartridgehasbeenreplaced,pressthe“CHECK/
RESET”buttonforfour(4)seconds.Along“beep”soundcanbeheard
andtheremainingcapacityontheLCDscreenisresetto1,000gallons.
6. LowBatteryPowerAlert:WhenthebatterypowerislowandthereiswaterflowingthroughthePID,a“beep-beep”
soundcanbeheardandtheemptybatterysymbolontheLCDscreenwillblinktonotifytheusertochangethe
batteries.ThePIDwillholdmemoryoftotalwaterflowrecordingwhilechangingbatteries.
OPERATION INSTRUCTIONS FOR THE DIGIFLOW 8800T
PERFORMANCE INDICATOR DEVICE (PID) — BG-12000 Only:
TROUBLESHOOTING GUIDE
Water Leaks at Push-In Connections:
Pushtubinginasfarasitwillgo.Ifleakingcontinues,shutoffwaterattheoriginalvalveandremovewaterlineby
pushinginontheconnectorcolletwhilepullingthetubingaway.Inspecttubingforcracksandscratches.Iftubingis
crackedorscratched,simplycutthatportionawayandreinserttubingintopush-intting.
Makesuretubingiscutsquarely.Ifnot,recutcorrectly.
Ifwaterleaks,pleaseverifythattheo-ringisproperlyseatedinitsgroove.
Water Does Not Flow From The Drinking Water System Faucet:
Checktoseeifthemainwaterlinevalveisopen,allowingwatertoowtothelter.Makesuretheconnectionsarenot
reversed.
Water Appears Cloudy or Air Comes Out of the Drinking Water System Faucet:
Flushlterforaminimumof4gallons(approximately5minutes),toremoveanycarbonnesortrappedairinthelter
and water lines.
Foranyservicerelatedissue,contactWater,Inc.at1-800-322-WATER(9283),extensions115or132
— 7 —
Figure 1
1/8”
(0.32 cm)
1/8”
(0.32 cm)
Figure 2
W-851 BG Combined MANUAL RELEASE COPY.pdf
The DigiFlow is multi-directional.

BodyGloveisaregisteredtrademarkofBodyGloveInternational,LLC.
©2008BodyGloveInternational,LLC.Allrightsreserved.
Manufactured by 3M
Internationally Distributed by Water,
Inc. 704 Kingshill Place
Carson,CA 90746
http://bodyglove.waterinc.com
800-322-WATER(9283)
For cartridge recycling information, please call
1-888-62-REUSE(73873)
or visit http://bodyglove.waterinc.com
W-851 BG Combined MANUAL RELEASE COPY.pdf
This manual suits for next models
2
Table of contents
Other Water Water Filtration System manuals
Popular Water Filtration System manuals by other brands

Miltenyi Biotec
Miltenyi Biotec MultiMACS M96 user manual

Kessel
Kessel EasyClean SkimTech Basic Translation of original instruction manual

Marine Depot
Marine Depot KleanWater RO user manual

SuperFish
SuperFish X-Pro 2000 UV manual

Speedaire
Speedaire 4ZL16 Operating instructions & parts manual

Barco
Barco F40 installation manual

amiad
amiad SAF-1500 Installation, operation and maintenance instructions

3M
3M CS-451 Installation and instruction manual

Salus
Salus MAG Defender MD22 instruction manual

FILTERMIST
FILTERMIST AX Series Installation and Maintenance

Dräger
Dräger 6738489 Instructions for use

Hayward
Hayward Aqua Trol AQ-TROL-HP-TL owner's manual