Wave Luxury M-1313 User manual

User’s Guide
IMPORTANT:
Read this manual before proceeding with installation of the bathtub and keep it
with the other accompanying documents.
This manual is valid for the installation of tubs both with and without whirlpool.
Massage bathtub
Page 1 of 11 1
9.5Temperature adjustment
9.5.1When the thermostatic heating function is on, press the Function
setting button “ ”till “℃" on LCD blinks, then press “ ”
and“ ” to adjust the temperature. During the adjusting,
LCD displays the setting temperature, then the temperature shall be
increased /decreased 1 ℃after press“ ”and “ ”once;
stop adjusting for 5 seconds,LCD shall display the current water
temperature.
9.6 If the temperature sensor occurs error, LCD displays “E1” and the
controller sounds “di…di…”, in this case the heater cannot be start.
10.Ozone
When the pump is working, press“ ”to turn on or turn off
the ozone. The ozone will be turned off automatically in 10 minutes.
11Drainage function after power off
Ensure that the main power supply is not cut-off. After turning off the
control panel, the drainage valve will be automatically turned on and
shut-off after 30 minutes.
(optional function)
SIZE:1700X1700X720mm
MODEL:M-1313

1
Massage bathtub Massage bathtub
Page 10 of 11 Page 1 of 11
Plane chart
Install the diagram
Tap takes over sketch
8.2Press “ ”till the LCD displays “BT--C”,the Bluetooth audio
play is turned on; press “ ”till the “BT--C” disappears, the
Bluetooth audio play is turned off.
8.3 If Bluetooth device is not paired successfully, the LCD blinks
"BT – C”; Bluetooth device pairing success, LCD displays “BT--C”.
8.4 When the Bluetooth audio play function is on ,press “ ”
and“ ” to select the songs.
8.5 When the Bluetooth Audio play function is on, press“ ”for
2seconds to operate play or pause function.
8.6 When the Bluetooth audio play function is on, press“ ”till
the LCD blinks “VOL”, and then press“ ”and“ ”to
increase and decrease the volume. The volume adjusting range
shall be 0-20,and 21in total.
9.Thermostatic heating
9.1This functions works only when the water pump surf function is on.
9.2Pres “ ”to start the thermostatic heating function.
9.2.1 2 seconds later,thermostatic heating function starts or stops
according to the temperature
(the temperature that the system defaults is 37℃)
Controlling rule is as follows:
If the temperature≥setting temperature+1℃,stop heating;
If the temperature≤setting temperature -1℃, stop heating.
9.3Press “ ”again to stop the function.
9.4Temperature setting range:35℃- 45℃
(optional function)
:
Cold water
Hot water
Waterfall drain
Spri nkl er drai n
Clear drain
Middle size jet
Control panel
Cold and hot water switch
Exchange switch
Big nozzle
Color light jets
Return net
Pop-up hand shower
Waterfall intake
Small nozzle
Pillow
Drainage
Return net
Drainage
Big nozzle

Massage bathtub Massage bathtub
Page 2 of 11 Page 9 of 11
1、Electricity parameter
Rated voltage Rated electric current Reference circuit voltage
220VAC 2200W <4A 12V
Rated power
2、Electric installation
2.1
2.2
2.3
2.4
power supply's establishment should be compled with nation security standard, voltage
and frequency also shoule be accord withproduct's nameplate.Especially install creep-
age protect switch and also check whether can connect with ground.
The wire collected to the massage bathtub should be fitting permanent., and the wire
should be a three-core wire, the sectional acreage of each core cannot less than 12A.
when wire pass the wall,it should be use bushing for protection until the AC outlet.
Ground wire of bathtub should be test whether works with house appliance ground wire.
The wire end of electricity control box should connect to the control panel, water bottom
light, loudspeaker, electrical engineering and the detector protection respectively.
3、Water supply device
3.1
This device's hydraulic pressure is 0.2-0.4Mpa.
3.2 The water supply characteristics on the wall: The cold or hot water supplies inside the
bathroom also establish in the shelter of the massage tub, use the hose to connect with
the cold or hot joint of the tub. the pipe towards is decide by the customer, the machine
do not go with the hose.
4.1
4.2
4.3
4.4
4.5
Before install, must consider the place of install massage bathtub whether can support
this device's pressure.
Place the massage bathtub on the install position, adjust level to make the drain system
smooth.
Adjust the leg's screw to make sure all of the screw touch ground completely.
Install the drain hose, and make some measure to against on the connecter.
Fix cold and hot water-pipe well, then install the showerhead. And then put drain into
downcomer, finally connect with power and make sure whether device connected with
ground can work.
5、Using Method
4、Installation introduction
5.1
5.2
5.3
Turn on faucet, adjust water's temperature, add water to the massage bathtub.when the
highest water level exceed the highest nozzle about 20-30mm and reach the detector,
press the switch button to let the electric machine.
Revolve the adjust switch ,and choose the proper surf pressure.
After finishing if should turn off pump at first, then open drain button,when water is all out ,
please make a clean of bathtub to keep in good.
6、Clean and keep in good condition
.
.
6.1 us ua lly use soft cloths and ge ne ral liqu id cleans er can wash aw ay dirt , bu t for bid to us e the
clea ns er wi th acet on e or the ammon ia comp os ition ;wh en disinf ect, for bi d to us e the di sinf ector
contai ne d the for mal de hyde .
6.2 the di rty spo t of sur face can us e the too thp aste to wi pe wi th the sof t cloth
6.3 to the low-gr ad e chafe of the surfac e or burne d by cigaret te, can soa k in water to wh et with 20 00 #
leviga tion san d pa pe r, then po lishing .
6.4 If the el ectrop late pi ec e con tain stai n, use the soft clot h to wi pe ligh tly, avoi d to wi ping with coarse clot h
6.5 of ten clean up the backwa ter net cov er, prev en t it from stop ;
6.6 Ch ec k wh et he r have br ea k on pipe and wa terway ap er iod ical ly.
7.3.2Press “ ”to decrease the length of one step (the length
of one step =100KHz). Press this button over 2 seconds, the system
searches the radio stations of smaller frequencies automatically;
the digital phase locked loop will lock the FM station automatically
and the liquid crystal shows the frequency of this station; When it
reaches to the limit of 87.5MHz, press this button again and the
frequency jumps to 108.0MHz.
7.4When the FM radio is on, press “ ”till the LCD blinks “VOL”
and Numbers, and then press“ ” to increase the volume and
press “ ”to decrease the volume. The volume adjusting range
is 0-20, and 21 in total.
7.5Station storage/select
7.5.1 Station storage:when FM function is on and select the station
frequency to be stored, press “ ” for 2seconds to select the
location for storage “CH” shall blink, and press “ ”to choose
the location; press the icon “ ”again, the station frequency
shall be stored in the selected storage location.
7.5.2 Station select:When FM function is on,press “ ”the
corresponding stored station can be selected while LCD displays
the corresponding storage location number and “CH”, 5 seconds
later, LCD displays the volume.
8Bluetooth Audio Play
8.1When the system is on and the audio play is off, press“ ”
for 2 seconds to check the Bluetooth device and the paring code
(LCD scrolling displays the Bluetooth device name and paring code)
and then press “ ”again for 2 seconds to set up the Bluetooth
deviceand the paring code (LCD scrolling displays the Bluetooth
device name and paring code).During this time, press “ ”to
exit the state (it will be exit automatically of non-press after 12 seconds)

Massage bathtub Massage bathtub
Page 8 of 11 Page 3 of 11
6.7 Pl ea se check whet he r there is fall off or br eakag e on wi re, swi tch,conne ctor plug s so that rep ai r
in time.
6.8 In or de r to keep to us e in a long ter m ,please reme mbe r, do n' t us e mor e than 3 ho ur s continu el y.
7、Fault eliminate
Remark: except this fault, please according to situation to resolve, or find
experienced people to repair.
8、special remind
8.1 please find qualified people to install bathtub according to introduction.
8.2 when you are using it, first of all you have to inject the cold water and then inject the
hot water. Don't inject the hot water first.
2
8.3 bathtub's machine must connect on ground, support must use 1.5mm yellow/green
double wire connect with ground and check whether effective.
8.4 please do not turn on machine without water, before draining should turn off machine.
8.5 children should be looked after in bathtub.
8.6 bathtub's temperature cann't higher than people average temperature, and the best
is 32-37centigrade.
8.7 after shower ,please cut off power.
8.8 if have these situation ,please do not enter into massage bathtub.
8.8.1 younger than 4 years old's child;
8.8.2 blood circulation unstabled people;
8.8.3 sot;
8.8.4 suffer from flu;
8.8.5 heart disease;
8.8.6 already have sauna;
8.8.7 after meal in half a hour;
Remark: our company has the right to modify the above mention without further notice.
Check circuitry
Insert again or change
power line
Connect again or change
Change
Connect with supplier
Fix tightly again
Adjust
Way
Change
Fix again
Change
Voltage unstable
Power connector didn't connect
well or open circuit
The windpipe connect air switch
fall off or break
Cause
Power's parameter is not same as
nameplate
Fixed screw did'n fix or fall off
Support's leg screw did not touch
ground
The joint did not fix well
Water pipe or accessory leak
Aging
Machine or equipment
doesn't work
water pipe leak out
Big nose of machine
Fault
The air switch failure
6.Waterfall&whirlpool
6.1 The water checking device of this controller protects the water
pump from burning out.
6.2 While the water level achieves the setting value , press“ ”
to start the Waterfall&whirlpool function and the icon blinks on the LCD
press again, Waterfall&Water pump surf is stopped.
6.3 When the water level lowers than the setting value, pump stops working.
6.4 When the Waterfall&whirlpool function is on, and the system checks
the water level lower than the setting value, Waterfall&whirlpool
function stops automatically, at the same time the pump icon blinks.
When anytime the system checks the water level achieves the setting
value, the icon stops blink and the pump starts to work.
Special alert:When turn on the function of whirlpool massage and
waterfall massage, press ( )can turn on the electrical water
volume adjustment function. Let both massages power keep changing
from maximum to minimum then maximum. When the waterfall volume
is at is maximum, then the jets are in weakest power, vice versa. Press
( )again can stop changing.
(optional function)
;
7.FM Radio
7.1 The FM frequency scope is 87.5MHz—108.0MHz.
7.2When the system is on, press the button “ ” to turn on the
FM Radio Function, at the same time, the LCD displays the current
frequency and “FM” “MHZ” press the icon “ ”again ,FM
function stops while the current frequency and “FM” disappears.
7.3 When the FM function is on, press “ ” till the LCD blinks
“FM” and “MHZ”, the system enter into the state of adjusting the
frequency.
7.3.1press “ ”to increase the length of one step (the length of
one step =100KHz): Press this button over 2 seconds, the system
searches the radio stations of larger frequencies automatically; the
digital phase locked loop will lock the FM station automatically and
the LCD shows the present frequency, when it reaches to the limit of
108.0MHz, press this button again and the frequency jumps to 87.5
Mhz.
.
;

Massage bathtub Massage bathtub
Page 4 of 11 Page 7 of 11
Bathtub User’s Guide
WARNINGS
CONTENTS
1.Please follow the instruction contained in the attached installation
manual to ensure that the product is installed properly.the manuf-
acturer will not be held liable for damages or injuries caused by im-
proper installation.
2.Follow the instructions contained in this manual when using the product.
3.Before using the bathbub, check the local voltage that if reach to the
rated voltage(pre-installation card).
Schematic Diagram of control panel
1) Foot massage pump
2) Pump
3) Lamp
4) Lock
5) Ozone
6) He a tin g
8) Ch a nne l s to r age / sel ect
7) Fu n cti o n se t tin g
10) Vo l ume / f re q uen c y plu s
11) M P3 、 FM、 B lu e too t h、T V
9) Vo l ume / f re q uen c y min us
12) Po w er on / of f
3.Operation of Control Panel
1. When any function button works, there is a sound of “di…”
2. Press “ ”for 2 seconds to start the controller ,at the same time,
the lamp is turned on ;press the icon again to stop the controller and
all the loads is turned off.
3. If no operation with the control panel for 5 minutes,all the
keys will be locked except “LOCK”, LCD displays “LOCK”.
4.Press the power switch icon, lamp is turned on,LCD displays
“ ”;then press“ ”,lamp is turned off;press “ ”
another time,lamp is turned on.
5. Foot massage pump:
Turn on the control panel, press ( ), then foot massage pump
start. Color light jets and foot massage jets start to work. ( )
is flashing when this function is working. Press ( )again to
stop this function, and it stop flashing.
Safety Precautions
Brief Introduction
6 .
Operation of Control Panel

Massage bathtub Massage bathtub
Page 6 of 11 Page 5 of 11
1. Safety Precautions
【Warning】
1. In order to prevent fire or electric shock accident, do not expose the controller
the rain or humid environment. There are dangerous high-tension fittings inside
the controller, therefore do not open the cover. Entrust the repairing work only
to the qualified professional repairing personnel when repairing is required.
2.Without the clear approval from the controller manufacturer or its authorized units,
any change or alternation to this controller might bring various inconveniences to
the users when in use.
to
【Helpful suggestion】
1. In order to prolong the service life of this controller, the time interval for continuously
turning on and off the machine must be over 30 seconds.
2.Please switch off the power after use.
3.The power supply used must be consistent with the voltage specified value indicated
on this controller; otherwise it will not work, or even burn out the controller.
4.When installing this controller, carefully check if the load parameters are consistent
with the parameters required by this controller, otherwise it will not work, or even burn
out the controller.
5.If it is halted accidentally, please close and restart.
2. Brief Introduction
1.General Description of Functions
Note:“*”stands for the optional function.
1Touching Technology √
2Lock √
3Waterfall&whirlpool √
4Foot massage pump *
5Bottom Light √
6Thermostatic Heating *
7FM Digital Turning Radio √
8Bluetooth Audio Play √
9Level Detection √
10 Ozone *
11 Cleaning √
Model
Functions PB304
2.1Controller System Including:
1)Control panel(1);
2)Control box(1).
2.2.Characteristics of the Controller
1)Rated voltage :AC220V ~AC240V
2)Working voltage range :AC198V ~ AC248V
3)Rated power :50HZ/60HZ
4)Power consumption :< 10W (all loads OFF)
5)Applied ambient temperature :+ 5℃~+40℃
2.3Devices controlled by the controlling system
1)Water pump surf :AC220V/3HP
2)Thermostatic heating :AC220V/2000W
3)Foot massage pump :AC220V/1HP
4)Bottom lamp :DC12V/5W
5)alternate output : AC12V/6W
Loudspeaker :8Ω/15W
AC230V Max 3HP
5.The LCD shows the following information
Table of contents
Other Wave Hot Tub manuals
Popular Hot Tub manuals by other brands

Laurel Mountain Whirlpools
Laurel Mountain Whirlpools COLONY owner's manual

ION
ION SUK-805D manual

Premium Leisure
Premium Leisure Leisure Edge LE852 owner's manual

Image
Image IMSB73911 user manual

Intex
Intex PureSpa SPJ-H-10-2 owner's manual

Canadian Spa
Canadian Spa Winnipeg UV Spa KH-10159 owner's manual

Aquatic
Aquatic HOTSOAK 85 ai6032SvhS Specification sheet

Marquis Spas
Marquis Spas Quest Operating and troubleshooting guide

CalderaSpas
CalderaSpas CalderaSpas Utopia Series Pre-delivery instructions

VIBIA
VIBIA 5975 Assembly instructions

Human Touch
Human Touch bodySPA Use & care manual

Poolspa
Poolspa VICTORIA SPA Installation and user manual